Micromechanical cantilever as an ultrasensitive pH microsensor
Abstract
We report on a pH sensor with ultrahigh sensitivity based on a microcantilever structure with a lithographically-defined crosslinked copolymeric hydrogel. Silicon-on-insulator wafers were used to fabricate cantilevers on which a polymer consisting of poly(methacrylic acid) (PMAA) with poly(ethylene glycol) dimethacrylate was patterned using free-radical UV polymerization. As the pH around the cantilever was increased above the pKa of PMAA, the polymer network expanded and resulted in a reversible change in surface stress causing the microcantilever to bend. Excellent mechanical amplification of polymer swelling as a function of pH change within the dynamic range was obtained, with a maximum deflection sensitivity of 1 nm/5×10−5 ΔpH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Hydrogels in Medicine and Pharmacy
Peppas, N. A. (1987) · Cited by 1,648
Self-citationLight-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
Smart single-chip gas sensor microsystem
Hagleitner, C., Hierlemann, A., Lange, D., Kummer, A., Kerness, N., Brand, O., & Baltes, H. (2001) · Nature · doi:10.1038/35104535 · Cited by 619
Surface micropatterning to regulate cell functions
Ito, Y. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00162-3 · Cited by 500
Origin of nanomechanical cantilever motion generated from biomolecular interactions
Wu, G., Ji, H., Hansen, K., Thundat, T., Datar, R., Cote, R., Hagan, M. F., Chakraborty, A. K., & Majumdar, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.4.1560 · Cited by 415
Brannon-Peppas, L., & Peppas, N. A. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90021-h · Cited by 190
Self-citationPhysiologically Responsive Hydrogels
Peppas, N. A. (1991) · Journal of Bioactive and Compatible Polymers · doi:10.1177/088391159100600303 · Cited by 160
Self-citationMicropatterning of biomedical polymer surfaces by novel UV polymerization techniques
Ward, J. H., Bashir, R., & Peppas, N. A. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20010905)56:3<351::aid-jbm1103>3.0.co;2-a · Cited by 104
Self-citationA novel pH sensitive ISFET with on chip temperature sensing using CMOS standard process
Chin, Y.-L., Chou, J.-C., Sun, T., Chung, W., & Hsiung, S.-K. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00639-6 · Cited by 94
Application of ISFETs for pH measurement in rain droplets
Poghossian, A., Baade, A., Emons, H., & Schöning, M. J. (2001) · Sensors and Actuators B Chemical · doi:10.1016/s0925-4005(01)00659-1 · Cited by 48
Scott, R. A., & Peppas, N. A. (1999) · Macromolecules · doi:10.1021/ma980612s · Cited by 41
Self-citationNakayama, Y., Anderson, J. M., & Matsuda, T. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200009)53:5<584::aid-jbm19>3.0.co;2-0 · Cited by 39
Microvolume field-effect pH sensor for the scanning probe microscope
Manalis, S. R., Cooper, E. B., Indermühle, P.-F., Kernen, P., Wagner, P., Hafeman, D. G., Minne, S. C., & Quate, C. F. (2000) · Applied Physics Letters · doi:10.1063/1.125942 · Cited by 22
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Self-citationHydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
Smart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
Hydrogel-based actuators: possibilities and limitations
Ionov, L. (2014) · Materials Today · doi:10.1016/j.mattod.2014.07.002 · Cited by 680
Metadata
- Authors
- Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2002-10-14
- Volume
- 81
- Issue
- 16
- Pages
- 3091-3093
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2114659148
- Cited by
- 300
- References
- 16
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.