The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Micromechanical cantilever as an ultrasensitive pH microsensor
Abstract
We report on a pH sensor with ultrahigh sensitivity based on a microcantilever structure with a lithographically-defined crosslinked copolymeric hydrogel. Silicon-on-insulator wafers were used to fabricate cantilevers on which a polymer consisting of poly(methacrylic acid) (PMAA) with poly(ethylene glycol) dimethacrylate was patterned using free-radical UV polymerization. As the pH around the cantilever was increased above the pKa of PMAA, the polymer network expanded and resulted in a reversible change in surface stress causing the microcantilever to bend. Excellent mechanical amplification of polymer swelling as a function of pH change within the dynamic range was obtained, with a maximum deflection sensitivity of 1 nm/5×10−5 ΔpH.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Functional hydrogel structures for autonomous flow control inside microfluidic channels
Beebe, D. J., Moore, J. S., Bauer, J. M., Yu, Q., Liu, R. H., Devadoss, C., & Jo, B.-H. (2000) · Nature · doi:10.1038/35007047 · Cited by 1,971
Hydrogels in Medicine and Pharmacy
Peppas, N. A. (1987) · Cited by 1,648
Self-citationLight-Addressable Potentiometric Sensor for Biochemical Systems
Hafeman, D. G., Parce, J. W., & McConnell, H. M. (1988) · Science · doi:10.1126/science.3375810 · Cited by 709
Bergveld, P. (1972) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1972.324137 · Cited by 654
Smart single-chip gas sensor microsystem
Hagleitner, C., Hierlemann, A., Lange, D., Kummer, A., Kerness, N., Brand, O., & Baltes, H. (2001) · Nature · doi:10.1038/35104535 · Cited by 619
Surface micropatterning to regulate cell functions
Ito, Y. (1999) · Biomaterials · doi:10.1016/s0142-9612(99)00162-3 · Cited by 500
Origin of nanomechanical cantilever motion generated from biomolecular interactions
Wu, G., Ji, H., Hansen, K., Thundat, T., Datar, R., Cote, R., Hagan, M. F., Chakraborty, A. K., & Majumdar, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.98.4.1560 · Cited by 415
Brannon-Peppas, L., & Peppas, N. A. (1990) · Biomaterials · doi:10.1016/0142-9612(90)90021-h · Cited by 190
Self-citationPhysiologically Responsive Hydrogels
Peppas, N. A. (1991) · Journal of Bioactive and Compatible Polymers · doi:10.1177/088391159100600303 · Cited by 160
Self-citation
Cited by
Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology
Peppas, N. A., Hilt, J. Z., Khademhosseini, A., & Langer, R. (2006) · Advanced Materials · doi:10.1002/adma.200501612 · Cited by 4,109
Self-citationHydrogels in sensing applications
Buenger, D., Topuz, F., & Groll, J. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.09.001 · Cited by 762
Smart polymers: Physical forms and bioengineering applications
Kumar, A., Srivastava, A., Galaev, I. Y., & Mattiasson, B. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.003 · Cited by 742
Review on Hydrogel-based pH Sensors and Microsensors
Richter, A., Paschew, G., Klatt, S., Lienig, J., Arndt, K.-F., & Adler, H.-J. P. (2008) · Sensors · doi:10.3390/s8010561 · Cited by 742
Hydrogel-based actuators: possibilities and limitations
Ionov, L. (2014) · Materials Today · doi:10.1016/j.mattod.2014.07.002 · Cited by 680
Micro- and nanomechanical sensors for environmental, chemical, and biological detection
Waggoner, P. S., & Craighead, H. G. (2007) · Lab on a Chip · doi:10.1039/b707401h · Cited by 678
Optical Sensing and Imaging of pH Values: Spectroscopies, Materials, and Applications
Steinegger, A., Wolfbeis, O. S., & Borisov, S. M. (2020) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00451 · Cited by 622
Stimuli-responsive hydrogel thin films
Tokarev, I., & Minko, S. (2009) · Soft Matter · doi:10.1039/b813827c · Cited by 579
Metal oxides based electrochemical pH sensors: Current progress and future perspectives
Manjakkal, L., Szwagierczak, D., & Dahiya, R. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2019.100635 · Cited by 481
Biomimetic Hydrogel‐Based Actuating Systems
Ionov, L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201203692 · Cited by 469
BioMEMS: state-of-the-art in detection, opportunities and prospects
Bashir, R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2004.03.002 · Cited by 462
Self-citationHydrogel-based devices for biomedical applications
Deligkaris, K., Tadele, T. S., Olthuis, W., & van den Berg, A. (2010) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2010.03.083 · Cited by 451
Microcantilevers: Sensing Chemical Interactions via Mechanical Motion
Goeders, K. M., Colton, J. S., & Bottomley, L. A. (2008) · Chemical Reviews · doi:10.1021/cr0681041 · Cited by 351
Tokarev, I., & Minko, S. (2010) · Advanced Materials · doi:10.1002/adma.201000165 · Cited by 349
Near-Infrared Light-Responsive Core–Shell Nanogels for Targeted Drug Delivery
Kang, H., Trondoli, A. C., Zhu, G., Chen, Y., Chang, Y.-J., Liu, H., Huang, Y.-F., Zhang, X., & Tan, W. (2011) · ACS Nano · doi:10.1021/nn201171r · Cited by 288
Healthcare Applications of pH-Sensitive Hydrogel-Based Devices: A Review
Hendi, A., Umair Hassan, M., Elsherif, M., Alqattan, B., Park, S., Yetisen, A. K., & Butt, H. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s245743 · Cited by 151
Mao, J., Kondu, S., Ji, H., & McShane, M. J. (2006) · Biotechnology and Bioengineering · doi:10.1002/bit.20755 · Cited by 75
Metadata
- Authors
- Bashir, R., Hilt, J. Z., Elibol, O., Gupta, A., & Peppas, N. A.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2002-10-14
- Volume
- 81
- Issue
- 16
- Pages
- 3091-3093
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2114659148
- Cited by
- 300
- References
- 16
- FWCI
- 9.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.