The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Density and atomic number measurements with spectral x-ray attenuation method
Abstract
X-ray attenuation measurements are widely used in medical and industrial applications. The usual results are one- to three-dimensional representations of the attenuation coefficient μ(r). In this paper, we present the ρZ projection algorithm for obtaining the density ρ(r) and atomic number Z(r) with an energy-resolving x-ray method. As input data the algorithm uses at least two measurements μ1,μ2,… with different spectral weightings of the source spectrum S(E) and/or detector sensitivity D(E). Analytically, ρ is a function of μ1−cμ2, c=const, and Z is a function of μ1/μ2. The full numerical treatment yields ρ(μ1,μ2) and Z(μ1,μ2) with S(E) and D(E) as commutative parametric functions. We tested the method with dual-energy computed tomography measurements of an organic sample and a set of chemical solutions with predefined ρ and Z. The resulting images show ρ and Z as complementary information: The density ρ reflects the morphology of the objects, whereas the atomic number Z=number of electrons/atom describes the material distribution. For our experimental setup we obtain an absolute precision of 0.1 for Z and 20 mg/cm3 for ρ. The ρZ projection can potentially lead to these classes of quantitative information for various scientific, industrial, and medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Method for transforming CT images for attenuation correction in PET/CT imaging
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006) · Medical Physics · doi:10.1118/1.2174132 · Cited by 271
Metadata
- Authors
- Heismann, B. J., Leppert, J., & Stierstorfer, K.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2003-08-01
- Volume
- 94
- Issue
- 3
- Pages
- 2073-2079
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2087707438
- Cited by
- 212
- References
- 1
- FWCI
- 1.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Density and atomic number measurements with spectral x-ray attenuation method. https://app.cochat.ai/papers/10.1063/1.1586963
- The paper
- Heismann, B. J., Leppert, J., & Stierstorfer, K. (2003). Density and atomic number measurements with spectral x-ray attenuation method. Journal of Applied Physics. https://doi.org/10.1063/1.1586963
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.