Method for transforming CT images for attenuation correction in PET/CT imaging

Carney, Jonathan P. J., Townsend, David W., Rappoport, Vitaliy, Bendriem, Bernard·2006·Medical Physics

Abstract

A tube‐voltage‐dependent scheme is presented for transforming Hounsfield units (HU) measured by different computed tomography (CT) scanners at different x‐ray tube voltages (kVp) to linear attenuation values for attenuation correction in positron emission tomography (PET) data reconstruction. A Gammex 467 electron density CT phantom was imaged using a Siemens Sensation 16‐slice CT, a Siemens Emotion 6‐slice CT, a GE Lightspeed 16‐slice CT, a Hitachi CXR 4‐slice CT, and a Toshiba Aquilion 16‐slice CT at kVp ranging from 80 to . All of these CT scanners are also available in combination with a PET scanner as a PET/CT tomograph. HU obtained for various reference tissue substitutes in the phantom were compared with the known linear attenuation values at . The transformation, appropriate for lung, soft tissue, and bone, yields the function below a threshold of and above the threshold, where and are fixed parameters that depend on the kVp setting. The use of the kVp‐dependent scaling procedure leads to a significant improvement in reconstructed PET activity levels in phantom measurements, resolving errors of almost 40% otherwise seen for the case of dense bone phantoms at . Results are also presented for patient studies involving multiple CT scans at different kVp settings, which should all lead to the same linear attenuation values. A linear fit to values obtained from CT images using the kVp‐dependent scaling plotted as a function of the corresponding values obtained from CT images yielded with an value of 0.999, indicating that the same values are obtained to a high degree of accuracy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.2174132

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 271

Metadata

Authors
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B.
Venue
Medical Physics
Publisher
Wiley
Published
2006-03-21
Volume
33
Issue
4
Pages
976-983
ISSN
  • 0094-2405 (ISSN-L)
  • 2473-4209
OpenAlex
W2035299311
Cited by
271
References
13
FWCI
6.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Method for transforming CT images for attenuation correction in PET/CT imaging. https://app.cochat.ai/papers/10.1118/1.2174132
The paper
Carney, J. P. J., Townsend, D. W., Rappoport, V., & Bendriem, B. (2006). Method for transforming CT images for attenuation correction in PET/CT imaging. Medical Physics. https://doi.org/10.1118/1.2174132

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.