The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Experimental test of scaling of mixing by chaotic advection in droplets moving through microfluidic channels
Open accessAbstract
This letter describes an experimental test of a simple argument that predicts the scaling of chaotic mixing in a droplet moving through a winding microfluidic channel. Previously, scaling arguments for chaotic mixing have been described for a flow that reduces striation length by stretching, folding, and reorienting the fluid in a manner similar to that of the baker’s transformation. The experimentally observed flow patterns within droplets (or plugs) resembled the baker’s transformation. Therefore, the ideas described in the literature could be applied to mixing in droplets to obtain the scaling argument for the dependence of the mixing time, t∼(aw/U)log(Pe), where w [m] is the cross-sectional dimension of the microchannel, a is the dimensionless length of the plug measured relative to w, U [m s−1] is the flow velocity, Pe is the Péclet number (Pe=wU/D), and D [m2 s−1] is the diffusion coefficient of the reagent being mixed. Experiments were performed to confirm the scaling argument by varying the parameters w, U, and D. Under favorable conditions, submillisecond mixing has been demonstrated in this system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Aref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationTice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Self-citationIsmagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Self-citationHypersensitive substrate for ribonucleases
Kelemen, B. R., Klink, T. A., Behike, M. A., Eubanks, S. R., Leland, P. A., & Raines, R. T. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.18.3696 · Cited by 194
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationMicrofluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Metadata
- Authors
- Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2003-12-01
- Volume
- 83
- Issue
- 22
- Pages
- 4664-4666
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2117056003
- Cited by
- 430
- References
- 11
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental test of scaling of mixing by chaotic advection in droplets moving through microfluidic channels. https://app.cochat.ai/papers/10.1063/1.1630378
- The paper
- Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F. (2003). Experimental test of scaling of mixing by chaotic advection in droplets moving through microfluidic channels. Applied Physics Letters. https://doi.org/10.1063/1.1630378
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.