The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Experimental test of scaling of mixing by chaotic advection in droplets moving through microfluidic channels
Open accessAbstract
This letter describes an experimental test of a simple argument that predicts the scaling of chaotic mixing in a droplet moving through a winding microfluidic channel. Previously, scaling arguments for chaotic mixing have been described for a flow that reduces striation length by stretching, folding, and reorienting the fluid in a manner similar to that of the baker’s transformation. The experimentally observed flow patterns within droplets (or plugs) resembled the baker’s transformation. Therefore, the ideas described in the literature could be applied to mixing in droplets to obtain the scaling argument for the dependence of the mixing time, t∼(aw/U)log(Pe), where w [m] is the cross-sectional dimension of the microchannel, a is the dimensionless length of the plug measured relative to w, U [m s−1] is the flow velocity, Pe is the Péclet number (Pe=wU/D), and D [m2 s−1] is the diffusion coefficient of the reagent being mixed. Experiments were performed to confirm the scaling argument by varying the parameters w, U, and D. Under favorable conditions, submillisecond mixing has been demonstrated in this system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Aref, H. (1984) · Journal of Fluid Mechanics · doi:10.1017/s0022112084001233 · Cited by 1,858
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Passive mixing in a three-dimensional serpentine microchannel
Liu, R. H., Stremler, M. A., Sharp, K. V., Olsen, M. G., Santiago, J. G., Adrian, R. J., Aref, H., & Beebe, D. J. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.846699 · Cited by 1,197
A Microfluidic System for Controlling Reaction Networks in Time
Song, H., Tice, J. D., & Ismagilov, R. F. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200390203 · Cited by 1,082
Self-citationTice, J. D., Song, H., Lyon, A. D., & Ismagilov, R. F. (2003) · Langmuir · doi:10.1021/la030090w · Cited by 722
Self-citationIsmagilov, R. F., Stroock, A. D., Kenis, P. J. A., Whitesides, G., & Stone, H. A. (2000) · Applied Physics Letters · doi:10.1063/1.126351 · Cited by 540
Self-citationHypersensitive substrate for ribonucleases
Kelemen, B. R., Klink, T. A., Behike, M. A., Eubanks, S. R., Leland, P. A., & Raines, R. T. (1999) · Nucleic Acids Research · doi:10.1093/nar/27.18.3696 · Cited by 194
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Self-citationNguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Deciding Whether To Go with the Flow: Evaluating the Merits of Flow Reactors for Synthesis
Hartman, R. L., McMullen, J. P., & Jensen, K. F. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201004637 · Cited by 999
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Transition from squeezing to dripping in a microfluidic T-shaped junction
DE MENECH, M., GARSTECKI, P., JOUSSE, F., & STONE, H. A. (2008) · Journal of Fluid Mechanics · doi:10.1017/s002211200700910x · Cited by 728
Scaling and the design of miniaturized chemical-analysis systems
Janasek, D., Franzke, J., & Manz, A. (2006) · Nature · doi:10.1038/nature05059 · Cited by 716
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693
Self-citationMicrodroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Shestopalov, I., Tice, J. D., & Ismagilov, R. F. (2004) · Lab on a Chip · doi:10.1039/b403378g · Cited by 571
Self-citationDroplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Collins, D. J., Neild, A., deMello, A., Liu, A.-Q., & Ai, Y. (2015) · Lab on a Chip · doi:10.1039/c5lc00614g · Cited by 528
Microchemical systems for continuous-flow synthesis
Hartman, R. L., & Jensen, K. F. (2009) · Lab on a Chip · doi:10.1039/b906343a · Cited by 508
Mixing in microfluidic devices and enhancement methods
Ward, K., & Fan, Z. H. (2015) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/25/9/094001 · Cited by 453
Micromixing Within Microfluidic Devices
Capretto, L., Cheng, W., Hill, M., & Zhang, X. (2011) · Topics in Current Chemistry · doi:10.1007/128_2011_150 · Cited by 448
Chen, D., Love, K. T., Chen, Y., Eltoukhy, A. A., Kastrup, C., Sahay, G., Jeon, A., Dong, Y., Whitehead, K. A., & Anderson, D. G. (2012) · Journal of the American Chemical Society · doi:10.1021/ja301621z · Cited by 424
Microfluidic systems for chemical kinetics that rely on chaotic mixing in droplets
Bringer, M. R., Gerdts, C. J., Song, H., Tice, J. D., & Ismagilov, R. F. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2003.1364 · Cited by 416
Self-citationMicrofluidic Devices for Drug Delivery Systems and Drug Screening
Damiati, S., Kompella, U. B., Damiati, S. A., & Kodzius, R. (2018) · Genes · doi:10.3390/genes9020103 · Cited by 383
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Effects of viscosity on droplet formation and mixing in microfluidic channels
Tice, J. D., Lyon, A. D., & Ismagilov, R. F. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.11.024 · Cited by 360
Self-citationIntegrated Microreactors for Reaction Automation: New Approaches to Reaction Development
McMullen, J. P., & Jensen, K. F. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.111808.073718 · Cited by 359
Du, W., Li, L., Nichols, K. P., & Ismagilov, R. F. (2009) · Lab on a Chip · doi:10.1039/b908978k · Cited by 351
Self-citationZheng, B., Tice, J. D., & Ismagilov, R. F. (2004) · Analytical Chemistry · doi:10.1021/ac0495743 · Cited by 321
Self-citationElectrokinetic mixing in microfluidic systems
Chang, C.-C., & Yang, R.-J. (2007) · Microfluidics and Nanofluidics · doi:10.1007/s10404-007-0178-z · Cited by 298
Why microfluidics? Merits and trends in chemical synthesis
Liu, Y., & Jiang, X. (2017) · Lab on a Chip · doi:10.1039/c7lc00627f · Cited by 291
Roach, L. S., Song, H., & Ismagilov, R. F. (2005) · Analytical Chemistry · doi:10.1021/ac049061w · Cited by 277
Self-citationManaging Solids in Microreactors for the Upstream Continuous Processing of Fine Chemicals
Hartman, R. L. (2012) · Organic Process Research & Development · doi:10.1021/op200348t · Cited by 260
Benz, C., Retzbach, H., Nagl, S., & Belder, D. (2013) · Lab on a Chip · doi:10.1039/c3lc00057e · Cited by 38
Metadata
- Authors
- Song, H., Bringer, M. R., Tice, J. D., Gerdts, C. J., & Ismagilov, R. F.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2003-12-01
- Volume
- 83
- Issue
- 22
- Pages
- 4664-4666
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2117056003
- Cited by
- 430
- References
- 11
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.