MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A point-contact (SQUID) magnetometer was used inside a shielded room to record the magnetic field of the human heart, without noise-averaging. The resulting magnetocardiograms, with the peak signal at about 3 × 10−7 G had a noise level of about 1 × 10−9 G (rms, per root cycle). They approach good medical electrocardiograms in clarity, and are an order-of-magnitude improvement in sensitivity over previous magnetic detectors of the heart. These results suggest new medical uses for this magnetometer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“finally providing an experimental setup and a magnetic signal-to-noise ratio (SNR) suitable for recording cardiac and even brain biomagnetic signals (13, 14).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [13]
Citations
Cites
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Self-citationDetection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Quantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Self-citationMagnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
Self-citationTheory of Magnetic Detection of the Heart's Electrical Activity
Baule, G., & McFee, R. (1965) · Journal of Applied Physics · doi:10.1063/1.1714404 · Cited by 112
Measurements and a Simplified Interpretation of Magnetocardiograms from Humans
COHEN, D., & CHANDLER, L. (1969) · Circulation · doi:10.1161/01.cir.39.3.395 · Cited by 50
Self-citation
Cited by
Cohen, D. (1972) · Science · doi:10.1126/science.175.4022.664 · Cited by 785
Self-citationSuperconducting quantum interference device instruments and applications
Fagaly, R. L. (2006) · Review of Scientific Instruments · doi:10.1063/1.2354545 · Cited by 594
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Wikswo, J. P. (1995) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.402511 · Cited by 201
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174
Fully integrated, standalone zero field optically pumped magnetometer for biomagnetism
Shah, V., Osborne, J., Orton, J., & Alem, O. (2018) · Steep Dispersion Engineering and Opto-Atomic Precision Metrology XI · doi:10.1117/12.2299197 · Cited by 173
Ferromagnetic Contamination in the Lungs and Other Organs of the Human Body
Cohen, D. (1973) · Science · doi:10.1126/science.180.4087.745 · Cited by 173
Self-citationSomatotopic organization of the human somatosensory cortex revealed by neuromagnetic measurements
Okada, Y. C., Tanenbaum, R., Williamson, S. J., & Kaufman, L. (1984) · Experimental Brain Research · doi:10.1007/bf00236274 · Cited by 163
Zimmerman, J. E., & Frederick, N. V. (1971) · Applied Physics Letters · doi:10.1063/1.1653725 · Cited by 152
Self-citationMagnetoencephalography - a noninvasive brain imaging method with 1 ms time resolution
Gratta, C. D., Pizzella, V., Tecchio, F., & Romani, G. L. (2001) · Reports on Progress in Physics · doi:10.1088/0034-4885/64/12/204 · Cited by 142
Magnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array
Wyllie, R., Kauer, M., Smetana, G. S., Wakai, R. T., & Walker, T. G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2619 · Cited by 125
Magnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Kim, Y. J., Savukov, I., & Newman, S. (2019) · Applied Physics Letters · doi:10.1063/1.5094339 · Cited by 133
Magnetoencephalography and Magnetic Source Imaging
Lewine, J. D., & Orrison, W. W. (1995) · Elsevier eBooks · doi:10.1016/b978-0-8151-6509-5.50013-8 · Cited by 133
Some new horizons in magnetic sensing: high-Tc SQUIDs, GMR and GMI materials
Mahdi, A. E., Panina, L. V., & Mapps, D. J. (2003) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(03)00106-7 · Cited by 128
SQUIDs in biomagnetism: a roadmap towards improved healthcare
Körber, R., Storm, J.-H., Seton, H. C., Mäkelä, J. P., Paetau, R., Parkkonen, L. T., Pfeiffer, C., Riaz, B., Schneiderman, J. F., Dong, H., et al. (2016) · Superconductor Science and Technology · doi:10.1088/0953-2048/29/11/113001 · Cited by 122
Magnetoencephalography (MEG) and Magnetic Source Imaging (MSI)
Wheless, J. W., Castillo, E., Maggio, V., Kim, H. L., Breier, J. I., Simos, P. G., & Papanicolaou, A. C. (2004) · The Neurologist · doi:10.1097/01.nrl.0000126589.21840.a1 · Cited by 113
(1974) · Journal of Perinatal Medicine · doi:10.1515/jpme.1974.2.3.214 · Cited by 112
Magnetomyography: magnetic fields around the human body produced by skeletal muscles
Cohen, D., & Givler, E. (1972) · Applied Physics Letters · doi:10.1063/1.1654294 · Cited by 109
Self-citationKwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor
Bison, G., Wynands, R., & Weis, A. (2003) · Optics Express · doi:10.1364/oe.11.000904 · Cited by 100
SQUID magnetocardiography: status and perspectives
Koch, H. (2001) · IEEE Transactions on Appiled Superconductivity · doi:10.1109/77.919284 · Cited by 91
Electromagnetic Bougienage to Lengthen Esophageal Segments in Congenital Esophageal Atresia
Hendren, W. H., & Hale, J. R. (1975) · New England Journal of Medicine · doi:10.1056/nejm197508282930905 · Cited by 93
Preprocessing and Denoising Techniques for Electrocardiography and Magnetocardiography: A Review
Jia, Y., Pei, H., Liang, J., Zhou, Y., Yang, Y., Cui, Y., & Xiang, M. (2024) · Bioengineering · doi:10.3390/bioengineering11111109 · Cited by 92
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
“Providing a significant improvement in sensitivity and spatial resolution of MF measurements, a major milestone in MCG was the invention of the first superconducting quantum interference device (SQUID) (10) and the installation of SQUID within the magnetically shielded room (MSR) of the Massachusetts Institute of Tech…”
BackgroundJensen, K., Skarsfeldt, M. A., Stærkind, H., Arnbak, J., Balabas, M. V., Olesen, S.-P., Bentzen, B. H., & Polzik, E. S. (2018) · Scientific Reports · doi:10.1038/s41598-018-34535-z · Cited by 79
Tolstrup, K., Madsen, B. E., Ruiz, J. A., Greenwood, S. D., Camacho, J., Siegel, R. J., Gertzen, H. C., Park, J.-W., & Smars, P. A. (2006) · Cardiology · doi:10.1159/000093490 · Cited by 78
Pena, M. E., Pearson, C. L., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. B. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 70
Josephson effect devices and low-frequency field sensing
Zimmerman, J. E. (1972) · Cryogenics · doi:10.1016/0011-2275(72)90133-6 · Cited by 78
Self-citationJodko-Władzińska, A., Wildner, K., Pałko, T., & Władziński, M. (2020) · Sensors · doi:10.3390/s20164563 · Cited by 76
Research in electrocardiography and magnetocardiography
McFee, R., & Baule, G. M. (1972) · Proceedings of the IEEE · doi:10.1109/proc.1972.8621 · Cited by 73
Multichannel SQUID system detecting tangential components of the cardiac magnetic field
Tsukada, K., Haruta, Y., Adachi, A., Ogata, H., Komuro, T., Ito, T., Takada, Y., Kandori, A., Noda, Y., Terada, Y., et al. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146524 · Cited by 69
1-pT Noise Fluxgate Magnetometer for Geomagnetic Measurements and Unshielded Magnetocardiography
Janosek, M., Butta, M., Dressler, M., Saunderson, E., Novotny, D., & Fourie, C. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2949205 · Cited by 70
Tsukada, K., Miyashita, T., Kandori, A., Mitsui, T., Terada, Y., Sato, M., Shiono, J., Horigome, H., Yamada, S., & Yamaguchi, I. (2000) · International journal of cardiac imaging · doi:10.1023/a:1006376326755 · Cited by 70
Thin Film Magnetoelectric Sensors Toward Biomagnetism: Materials, Devices, and Applications
Dong, C., Liang, X., Gao, J., Chen, H., He, Y., Wei, Y., Zaeimbashi, M., Matyushov, A. D., Sun, C., & Sun, N. X. (2022) · Advanced Electronic Materials · doi:10.1002/aelm.202200013 · Cited by 69
Wearable OPM-MEG: a changing landscape for epilepsy
Pedersen, M., Abbott, D. F., & Jackson, G. D. (2022) · Epilepsia · doi:10.1111/epi.17368 · Cited by 68
Multichannel SQUID Biomagnetic Systems
Vrba, J. (2000) · Springer eBooks · doi:10.1007/978-94-017-0752-7_2 · Cited by 67
Biomagnetism: The First Sixty Years
Roth, B. J. (2023) · Sensors · doi:10.3390/s23094218 · Cited by 66
Multichannel DC SQUID sensor array for biomagnetic applications
Hoenig, H. E., Daalmans, G., Bär, L., Bömmel, F., Paulus, A., Uhl, D., Weisse, H., Schneider, S., Seifert, H., Reichenberger, H., et al. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133787 · Cited by 64
Superconducting Quantum Interference Devices for Low Frequency Measurements
Clarke, J. L. (1977) · Springer eBooks · doi:10.1007/978-1-4684-2805-6_3 · Cited by 64
Converse Magnetoelectric Composite Resonator for Sensing Small Magnetic Fields
Hayes, P., Klug, M. J., Toxvaerd, S., Durdaut, P., Schell, V., Teplyuk, A., Burdin, D. A., Winkler, A., Weser, R., Fetisov, Y. K., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-52657-w · Cited by 64
Optimization and performance of an optical cardiomagnetometer
Bison, G., Wynands, R., & Weis, A. (2005) · Journal of the Optical Society of America B · doi:10.1364/josab.22.000077 · Cited by 62
Magnetic field associated with spreading depression: a model for the detection of migraine
Okada, Y. C., Lauritzen, M., & Nicholson, C. (1988) · Brain Research · doi:10.1016/0006-8993(88)91450-3 · Cited by 62
Gallop, J. C., & Petley, B. W. (1976) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/9/6/001 · Cited by 54
Thermography at millimeter wavelengths
EDRICH, J., & Hardee, P. C. (1974) · Proceedings of the IEEE · doi:10.1109/proc.1974.9630 · Cited by 54
Cohen, D., Norman, J. C., Molokhia, F., & Hood, W. (1971) · Science · doi:10.1126/science.172.3990.1329 · Cited by 53
Self-citationNeuromagnetic functional localization: principles, state of the art, and perspectives
Romani, G. L., & Rossini, P. (1988) · Brain Topography · doi:10.1007/bf01129335 · Cited by 51
Moshage, W. E. L., Achenbach, S. S., Göhl, K., & Bachmann, K. F. (1996) · International journal of cardiac imaging · doi:10.1007/bf01798116 · Cited by 51
Superconducting instrument systems
Goodman, W. L., Hesterman, V. W., Rorden, L. H., & Goree, J. (1973) · Proceedings of the IEEE · doi:10.1109/proc.1973.8965 · Cited by 51
Applications of closed-cycle cryocoolers to small superconducting devices
Zimmerman, J. E., & Flynn, T. M. (1978) · doi:10.6028/nbs.sp.508 · Cited by 50
Self-citationSmith, F. E., Langley, P., van Leeuwen, P., Hailer, B., Trahms, L., Steinhoff, U., Bourke, J. P., & Murray, A. (2006) · EP Europace · doi:10.1093/europace/eul070 · Cited by 47
Bioelectrodynamics in living organisms
Zhou, S., & Uesaka, M. (2005) · International Journal of Engineering Science · doi:10.1016/j.ijengsci.2005.11.001 · Cited by 49
Magnetocardiograms and their variation over the chest in normal subjects
Cohen, D., & McCaughan, D. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90170-1 · Cited by 49
Self-citationRecent Developments in Superconducting Devices
Zimmerman, J. E. (1971) · Journal of Applied Physics · doi:10.1063/1.1659587 · Cited by 49
Self-citationAyres, N. J., Ban, G., Bison, G., Bodek, K., Бондар, В. М., Bouillaud, T., Clément, B., Chanel, E., Chiu, P.-J., Crawford, C., et al. (2022) · Review of Scientific Instruments · doi:10.1063/5.0101391 · Cited by 47
Kandori, A., Kanzaki, H., Miyatake, K., Hashimoto, S., Itoh, S., Tanaka, N., Miyashita, T., & Tsukada, K. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345262 · Cited by 47
Compact multi-channel optically pumped magnetometer for bio-magnetic field imaging
Yuan, Z., Liu, Y., Xiang, M., Gao, Y., Suo, Y., Ye, M., & Zhai, Y. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109534 · Cited by 45
Focus on SQUIDs in Biomagnetism
Clarke, J., Lee, Y., & Schneiderman, J. F. (2018) · Superconductor Science and Technology · doi:10.1088/1361-6668/aacb14 · Cited by 44
Nakaya, Y., & Mori, H. (1992) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/13/3/001 · Cited by 39
Superconducting quantum magnetometers
Webb, W. W. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067263 · Cited by 44
del Campo, A. A., Sparks, A., Hill, R. C., & Keller, R. T. (1999) · IEEE Transactions on Engineering Management · doi:10.1109/17.775281 · Cited by 43
Boston and the history of biomagnetism.
Cohen, D. (2004) · PubMed · Cited by 43
Self-citationMagnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42
Hoenig, H. E., Daalmans, G., Folberth, W., Reichenberger, H., Schneider, S., & Seifert, H. (1989) · Cryogenics · doi:10.1016/0011-2275(89)90154-9 · Cited by 42
Clarke, J. L. (1974) · Science · doi:10.1126/science.184.4143.1235 · Cited by 40
Horigome, H., Shiono, J., Shigemitsu, S., Asaka, M., Matsui, A., Kandori, A., Miyashita, T., & Tsukada, K. (2001) · Pediatric Research · doi:10.1203/00006450-200108000-00013 · Cited by 39
Application of SQUID sensors to the investigation of neural activity in the human brain
Williamson, S. J., & Kaufman, L. (1983) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1983.1062555 · Cited by 38
Diagnosing intestinal ischemia using a noncontact superconducting quantum interference device
Golzarian, J., Staton, D. J., Wikswo, J. P., Friedman, R. N., & Richards, W. O. (1994) · The American Journal of Surgery · doi:10.1016/0002-9610(94)90103-1 · Cited by 37
Orrison, W. W., Davis, L. E., Sullivan, G. W., Mettler, F. A., & Flynn, E. R. (1990) · PubMed · Cited by 36
Magnetic field associated with neural activities in an isolated cerebellum
Okada, Y. C., Lauritzen, M., & Nicholson, C. (1987) · Brain Research · doi:10.1016/0006-8993(87)91451-x · Cited by 35
Fujino, K., Sumi, M., Saito, K., Murakami, M., Higuchi, T., Nakaya, Y., & Mori, H. (1984) · Journal of Electrocardiology · doi:10.1016/s0022-0736(84)80058-8 · Cited by 35
Analysis of current source of the heart using Isomagnetic and Vector arrow maps.
Nakaya, Y., Sumi, M., Saito, K., Fujino, K., Murakami, M., & Mori, H. (1984) · Japanese Heart Journal · doi:10.1536/ihj.25.701 · Cited by 35
Nakai, K., Izumoto, H., Kawazoe, K., Tsuboi, J., Fukuhiro, Y., Oka, T., Yoshioka, K., Shozushima, M., Itoh, M., Suwabe, A., et al. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-005-9019-x · Cited by 34
Nakai, K., Kawazoe, K., Izumoto, H., Tsuboi, J., Oshima, Y., Oka, T., Yoshioka, K., Shozushima, M., Suwabe, A., Itoh, M., et al. (2005) · International journal of cardiac imaging · doi:10.1007/s10554-005-0652-1 · Cited by 34
Zhang, J., Liu, K., Zhang, J., Wang, Z., & Shang, J. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3120375 · Cited by 33
Biomagnetometry: imaging the heart's magnetic field.
Hart, G. (1991) · Heart · doi:10.1136/hrt.65.2.61 · Cited by 33
Active Magnetic-Field Stabilization with Atomic Magnetometer
Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H. (2020) · Sensors · doi:10.3390/s20154241 · Cited by 32
Inaba, T., Nakazawa, Y., Yoshida, K., Kato, Y., Hattori, A., Kimura, T., Hoshi, T., Ishizu, T., Seo, Y., Sato, A., et al. (2017) · Superconductor Science and Technology · doi:10.1088/1361-6668/aa8c26 · Cited by 32
Progress in Biomagnetic Imaging of Heart Arrhythmias
Moshage, W. E. L., Achenbach, S. S., Weikl, A., Göhl, K., Abraham‐Fuchs, K., Schneider, S., & Bachmann, K. (1991) · Frontiers in European radiology · doi:10.1007/978-3-642-76099-0_1 · Cited by 31
Magnetic property mapping system for analyzing three-dimensional magnetic components
Tsukada, K., & Kiwa, T. (2006) · Review of Scientific Instruments · doi:10.1063/1.2209949 · Cited by 28
Localization of biological sources with arrays of superconducting gradiometers
Carelli, P., & Leoni, R. (1986) · Journal of Applied Physics · doi:10.1063/1.336625 · Cited by 27
Magnetocardiography: An Overview
Geselowitz, D. B. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326430 · Cited by 26
The role of magnetoencephalography in pediatric epilepsy surgery
Grondin, R., Chuang, S. H., Otsubo, H., Holowka, S. A., Snead, O. C., Raybaud, C., & Rutka, J. T. (2006) · Child s Nervous System · doi:10.1007/s00381-006-0124-5 · Cited by 25
Sensing magnetic flux density of artificial neurons with a MEMS device
Tapia, J. A., Herrera‐May, A. L., Garcia-Ramirez, P. J., Martínez-Castillo, J., Figueras, E., Flores, A., & Manjarrez, E. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9494-2 · Cited by 25
High-Resolution Measurements of Biomagnetic Fields
Wikswo, J. P. (1988) · Advances in cryogenic engineering · doi:10.1007/978-1-4613-9874-5_13 · Cited by 25
Tsukada, K., Mitsui, T., Terada, Y., Horigome, H., & Yamaguchi, I. (1999) · Journal of Electrocardiology · doi:10.1016/s0022-0736(99)90001-8 · Cited by 25
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Brisinda, D., Caristo, M. E., & Fenici, R. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01048.2005 · Cited by 23
Magnetic fields produced by single motor units in human skeletal muscles
Masuda, T., Endô, H., & Takeda, T. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00021-2 · Cited by 23
Kim, K., Lee, W., Kim, I.-S., & Moon, H. S. (2007) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.890610 · Cited by 23
THE EVOKED MAGNETIC FIELD OF THE HUMAN BRAIN*
Kaufman, L., & Williamson, S. J. (1980) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1980.tb35160.x · Cited by 23
Evoked neuromagnetic fields of the human brain
Williamson, S. J., Kaufman, L., & Brenner, D. A. (1979) · Journal of Applied Physics · doi:10.1063/1.326972 · Cited by 23
Frei, E. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067327 · Cited by 23
Nomura, M., Fujino, K., Katayama, M., Takeuchi, A., Fukuda, Y., Sumi, M., Murakami, M., Nakaya, Y., & Mori, H. (1988) · Journal of Electrocardiology · doi:10.1016/s0022-0736(88)80014-1 · Cited by 23
Biomagnetism: An application of squid sensors to medicine and physiology
Romani, G. L. (1984) · Physica B+C · doi:10.1016/0378-4363(84)90147-5 · Cited by 23
An Integrated Maximum Current Density Approach for Noninvasive Detection of Myocardial Infarction
Zhao, C., Jiang, S., Wu, Y., Zhu, J., Zhou, D., Hailer, B., Grönemeyer, D. H. W., & Leeuwen, P. V. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2649570 · Cited by 22
Solving the Magnetocardiography Forward Problem in a Realistic Three-Dimensional Heart-Torso Model
Hu, Z., Ye, K., Bai, M., Yang, Z., & Lin, Q. (2021) · IEEE Access · doi:10.1109/access.2021.3098925 · Cited by 22
Calculation of an optimized design of magnetic shields with integrated demagnetization coils
Sun, Z., Schnabel, A., Burghoff, M., & Li, L. (2016) · AIP Advances · doi:10.1063/1.4960329 · Cited by 22
Silver, A. H., & Zimmerman, J. E. (1975) · Elsevier eBooks · doi:10.1016/b978-0-12-517701-6.50007-0 · Cited by 22
Self-citationIkefuji, H., Nomura, M., Nakaya, Y., Mori, T., Kondo, N., Ieishi, K., Fujimoto, S., & Ito, S. (2007) · The Journal of Medical Investigation · doi:10.2152/jmi.54.116 · Cited by 19
Metadata
- Authors
- Cohen, D., Edelsack, E. A., & Zimmerman, J. E.
- Affiliations
- Massachusetts Institute of Technology (US)
- Office of Naval Research (US)
- Philco-Ford (United States) (US)
- ORCID
- Cohen, David
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1970-04-01
- Volume
- 16
- Issue
- 7
- Pages
- 278-280
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2055429396
- Cited by
- 361
- References
- 6
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 9 · 2021: 5 · 2020: 9 · 2019: 8 · 2018: 8 · 2017: 5 · 2016: 2 · 2015: 4 · 2014: 8 · 2013: 13 · 2012: 7
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, SQUID magnetometer, superconducting magnetometer, cardiac magnetic field, magnetic shielding, noise sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.