MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A point-contact (SQUID) magnetometer was used inside a shielded room to record the magnetic field of the human heart, without noise-averaging. The resulting magnetocardiograms, with the peak signal at about 3 × 10−7 G had a noise level of about 1 × 10−9 G (rms, per root cycle). They approach good medical electrocardiograms in clarity, and are an order-of-magnitude improvement in sensitivity over previous magnetic detectors of the heart. These results suggest new medical uses for this magnetometer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“finally providing an experimental setup and a magnetic signal-to-noise ratio (SNR) suitable for recording cardiac and even brain biomagnetic signals (13, 14).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [13]
Citations
Cites
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Self-citationDetection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Quantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Self-citationMagnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
Self-citationTheory of Magnetic Detection of the Heart's Electrical Activity
Baule, G., & McFee, R. (1965) · Journal of Applied Physics · doi:10.1063/1.1714404 · Cited by 112
Measurements and a Simplified Interpretation of Magnetocardiograms from Humans
COHEN, D., & CHANDLER, L. (1969) · Circulation · doi:10.1161/01.cir.39.3.395 · Cited by 50
Self-citation
Cited by
Items 201–300 of 406
Tsukada, K., & Kiwa, T. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.l532 · Cited by 4
Thiriet, M. (2015) · Springer eBooks · doi:10.1007/978-3-642-37078-6_25 · Cited by 4
Ogata, K., Kandori, A., Miyashita, T., Sekihara, K., & Tsukada, K. (2011) · Review of Scientific Instruments · doi:10.1063/1.3529440 · Cited by 4
Measurements of the magnetocardiography in unshielded environment using high-Tc rf SQUID gradiometer
He, D., Zhang, F., Xie, F., Dai, Y., Wang, S. G., Ma, P., Yang, T., Wang, S. Z., Chen, W. C., & Wang, Z. Q. (2000) · Physica C Superconductivity · doi:10.1016/s0921-4534(00)01429-5 · Cited by 4
A simplified HTc rf SQUID to analyze the human cardiac magnetic field
Zhang, C., Tang, F., Ma, P., & Gan, Z. (2014) · AIP Advances · doi:10.1063/1.4904429 · Cited by 4
SQUID Instruments and Applications
Fagaly, R. L., & Technologies, T. (2005) · Cited by 4
Superconducting Quantum Interference (SQUIDs)
Fagaly, R. L., Krause, H., Mück, M., Tanaka, S., Nowak, H., Stolz, R., Kirtley, J. R., Schurig, T., Beyer, J., McDermott, R., et al. (2015) · Wiley eBooks · doi:10.1002/9783527670635.ch9 · Cited by 4
Biomagnetism Attracts Diverse Crowd
Crease, R. P. (1989) · Science · doi:10.1126/science.2772655 · Cited by 4
Wheless, J. W., Castillo, E. M., & Papanicolaou, A. C. (2006) · Elsevier eBooks · doi:10.1016/b978-0-7506-7251-1.50043-5 · Cited by 4
Atrial Electric Signal During Sinus Rhythm in Lone Paroxysmal Atrial Fibrillation
Jurkko, R. (2009) · Helda - University of Helsinki Institutional Repository · Cited by 4
Estudio conjunto de magnetoencefalografía y electroencefalografía en epilepsia
Sanz, L. G. (2011) · Tesis Doctorals en Xarxa (Consorci de Serveis Universitaris de Catalunya) · Cited by 4
Superconducting instrumentation for biomagnetism
Romani, G. L. (1979) · International Journal of Refrigeration · doi:10.1016/0140-7007(79)90086-0 · Cited by 4
Constant temperature thermostat for electronic noise measurements at frequencies above 1 μHz.
Boehm, T., & Bilger, H. R. (1976) · Review of Scientific Instruments · doi:10.1063/1.1134824 · Cited by 4
The Use of SQUIDs in the Study of Biomagnetic Fields
Romani, G. L. (1989) · Springer eBooks · doi:10.1007/978-3-642-83885-9_6 · Cited by 4
Developments in Cryoelectronics
Kamper, R. A. (1972) · doi:10.6028/nbs.tn.630 · Cited by 4
Superconducting microwave magnetometer for absolute flux detectionPreprint
Günzler, S., Winkel, P., Rieger, D., Borisov, K., Spiecker, M., Ustinov, A. V., Pop, I. M., & Wernsdorfer, W. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2107.05929 · Cited by 4
Magnetoencephalography and Epilepsy
Vieth, J. (1987) · Springer eBooks · doi:10.1007/978-3-642-71103-9_21 · Cited by 4
Reconstruction of the Human Heart Functional Structure Based On a Few-Channel Magnetocardiogram
Ustinin, M. N., Maslennikov, Y. V., Rykunov, S. D., & Krymov, V. A. (2018) · Mathematical Biology and Bioinformatics · doi:10.17537/2018.13.392 · Cited by 3
Application of flat dc-thin film SQUID's and technique for biomagnetic measurements
Albrecht, G. T., Hiibert, A., Kirsch, G., Nowak, H., Vodel, W., & Zach, H. G. (1981) · Cryogenics · doi:10.1016/0011-2275(81)90231-9 · Cited by 3
la Roca-Chiapas, J. M. D. (2012) · InTech eBooks · doi:10.5772/36604 · Cited by 3
Thiriet, M. (2013) · Biomathematical and biomechanical modeling of the circulatory and ventilatory systems · doi:10.1007/978-1-4614-9469-0_3 · Cited by 3
Optimization of a squid vector gradiometer
Lekkala, J. O., & Malmivuo, J. A. (1985) · Cryogenics · doi:10.1016/0011-2275(85)90012-8 · Cited by 3
Biomagnetic Measurement by SQUID Magnetometer. 1. SQUID Magnetometer.
Kasai, N. (1991) · TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan) · doi:10.2221/jcsj.26.344 · Cited by 3
Medical Applications of Magnetism: A New Look at an Archaic Tool
Frei, E. H. (1972) · Bulletin of the Atomic Scientists · doi:10.1080/00963402.1972.11457968 · Cited by 3
Microfabricated SERF Atomic Magnetometers for Measurement of Weak Magnetic Field
Liu, K., Shang, J., Zhang, J., Yue, X., Ye, C., Zhang, J., & Wong, C. (2020) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc32862.2020.00161 · Cited by 3
Evolution of the SQUID and its Use in Biomagnetic Research
Zimmerman, J. E. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_6 · Cited by 3
Self-citationKing, C. A. (1971) · Review of Scientific Instruments · doi:10.1063/1.1684981 · Cited by 3
High-resolution recordings of the magnetic activity of the His-Bundle in man
Erne, S. N., Fenici, R., Hahlbohm, H.-D., Lehmann, H. P., & Trontelj, Z. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02457146 · Cited by 3
Squid biomagnetic measurements
Farrell, D. E., & Zanzucchi, P. E. (1983) · Critical reviews in solid state and materials sciences/CRC critical reviews in solid state and materials sciences · doi:10.1080/01611598308244061 · Cited by 3
Magnetic Fields of the Brain Resulting from Normal and Pathological Function
Weinberg, H., Robertson, A. W., Crisp, D., & Johnson, B. W. (1990) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4757-1083-0_25 · Cited by 3
Measurement of two-dimensional impedance magnetocardiogram. Model experiment
Kandori, A., Suzuki, D., Miyashita, T., Yokosawa, K., & Tsukada, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2001.1018938 · Cited by 3
Magnetic Mapping of the Human Thorax Using a SQUID Magnetometer
Khenia, S., Melville, D., & Rassi, D. (1986) · Springer proceedings in physics · doi:10.1007/978-3-642-71526-6_39 · Cited by 3
Biomagnetic Measurements in Unshielded Environment
Nowak, H., Albrecht, G. T., Berthel, K. ‐., Burghoff, M., Haberkorn, W., & Zach, H. G. (1988) · Springer eBooks · doi:10.1007/978-1-4613-1025-9_17 · Cited by 3
Elbert, T. (1998) · KOPS (University of Konstanz) · Cited by 3
SERF magnetometer array using concurrent amplitude-stabilized optical modulation
Yue, Z., Zhai, Y., Wang, Y., Xu, X., & Tang, J. (2025) · Alexandria Engineering Journal · doi:10.1016/j.aej.2025.05.057 · Cited by 2
Anu, K. V., Bhat, V. R., Reshma, H., & Anitha, H. (2025) · IEEE Access · doi:10.1109/access.2025.3608853 · Cited by 2
On-chip Magnetic Sensor with Embedded High Inductance Coil for Bio-magnetic Signal Measurement
Lyu, H., & Choi, J. R. (2013) · Journal of the Institute of Electronics and Information Engineers · doi:10.5573/ieek.2013.50.6.091 · Cited by 2
Thiriet, M. (2013) · Biomathematical and biomechanical modeling of the circulatory and ventilatory systems · doi:10.1007/978-1-4614-9469-0_4 · Cited by 2
Magnetically Shielded Room for Biomagnetic Measurement.
Ishikawa, N., HARAKAWA, K., & Kado, H. (1993) · TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan) · doi:10.2221/jcsj.28.237 · Cited by 2
Oschman, J. L. (2015) · Elsevier eBooks · doi:10.1016/b978-0-443-06729-7.00008-9 · Cited by 2
Clinical Use of Electrocardiogram
Lakshmanadoss, U. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.98009 · Cited by 2
High stability magnetic field compensation method based on ACAC-DOB
Gong, A., Cui, P., Yang, Z., Jin, Y., Yao, J., & Li, Y. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/adf089 · Cited by 2
Nakai, K., Itoh, M., Okabayashi, H., Tsuboi, J., Mitsunaga, Y., Komatsu, T., & Yoshioka, K. (2012) · International Heart Journal · doi:10.1536/ihj.53.5 · Cited by 2
Kandori, A., Suzuki, D., Tsukamoto, A., Kumagai, Y., Miyashita, T., Ogata, K., Seki, Y., Yokosawa, K., & Tsukada, K. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.6513 · Cited by 2
Demachi, K., Rybalko, S., & Fujita, M. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2007.916366 · Cited by 2
A solid-state matrix of adaptive weights based on domain tip motion in thin permalloy films
Boyarchenkov, M., Gostev, V., & Raev, V. K. (1972) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1972.1067326 · Cited by 2
Linearization of GMI Sensors by Neuronal Networks for Medical Applications
Meier, P., Sandner, M., Rohrmann, K., Ferhi, O., & Prochaska, M. (2020) · IEEE Global Conference on Life Sciences and Technologies (LifeTech) · doi:10.1109/lifetech48969.2020.1570614629 · Cited by 2
The Wisdom and Vision From the ACMEGS Inaugural Decade
Bagic, A. I., Funke, M. E., & Burgess, R. C. (2020) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000744 · Cited by 2
Towards Clinical MCG with Room-Temperature Sensors
Lembke, G., Stumpf, M., Erne, S. N., & Bison, G. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_10 · Cited by 2
First-order SQUID gradiometer with electronic subtraction for magnetocardiography
Rau, M. C., & Octavian, B. (2012) · International Conference and Exposition on Electrical and Power Engineering (EPE) · doi:10.1109/icepe.2012.6463873 · Cited by 2
Mori, H., Nakaya, Y., Murakami, M., NOMURA, M., & Takeuchi, A. (1987) · TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan) · doi:10.2221/jcsj.22.233 · Cited by 2
Hänninen, H. (2002) · Helda - University of Helsinki Institutional Repository · Cited by 2
Sensitivity Limits in Biomagnetic Measurements
Katila, T. E., Leiniö, M., Montonen, J., & Nenonen, J. T. (1991) · Acta Oto-Laryngologica · doi:10.3109/00016489109136779 · Cited by 2
Magnetometers and Interference Devices
Webb, W. W. (1973) · Springer eBooks · doi:10.1007/978-1-4615-8978-5_11 · Cited by 2
The advancement of magnetoneurography
Afra, P. (2020) · Clinical Neurophysiology · doi:10.1016/j.clinph.2019.12.406 · Cited by 2
Cheyne, D., & Verba, J. (2006) · Wiley eBooks · doi:10.1002/0471732877.emd019 · Cited by 2
Ilmoniemi, R. J., & Näätänen, R. J. (2001) · Elsevier eBooks · doi:10.1016/b0-08-043076-7/03411-2 · Cited by 2
Boll, R. (1989) · Sensors · doi:10.1002/9783527620166.ch1 · Cited by 2
Hat die Magnetokardiografie eine klinische Zukunft?
Esperer, H.-D. (1997) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/bf03042395 · Cited by 2
Magnetocardiography in assessment of ventricular arrhythmia risk
Korhonen, P. (2002) · Helda - University of Helsinki Institutional Repository · Cited by 2
Introduction to superconducting quantum interference device
Ponselvan, D. Y. S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00013-9 · Cited by 2
Edge-aware multi-head transformer for noise-robust full-field magnetocardiography signal modeling
Wang, J., Shen, H., Guo, J., Xu, X., Liu, L., Ma, J., & Shen, C. (2026) · The Visual Computer · doi:10.1007/s00371-025-04260-6 · Cited by 1
Anatomy of the Ventilatory Apparatus
Thiriet, M. (2013) · Biomathematical and biomechanical modeling of the circulatory and ventilatory systems · doi:10.1007/978-1-4614-9469-0_2 · Cited by 1
Youn, T. J., Kim, Y. G., Oh, K. S., Piao, H., Kwon, J. S., Choi, S. Y., Kim, D. W., Cho, M., Lee, Y., & Kwon, H. (2002) · Korean Circulation Journal · doi:10.4070/kcj.2002.32.4.330 · Cited by 1
Research on models and methods of Magnetocardiography
Lu, Y. (2010) · International Conference on Networking and Digital Society (ICNDS) · doi:10.1109/icnds.2010.5479444 · Cited by 1
Current dipole estimation with electromagnetocardiography
Akkaya, I. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1997.754547 · Cited by 1
Effect of Niobium Cylinder on Output of the 3D SQUID Gradiometer
Yang, R., Yang, K. Y., Wang, J., Kong, X., Weichen, & Liang, T. (2018) · International Conference on Applied Superconductivity and Electromagnetic Devices · doi:10.1109/asemd.2018.8558901 · Cited by 1
Boll, R. (1995) · Wiley eBooks · doi:10.1002/9783527619269.ch1d · Cited by 1
Ayres, N. J., Ban, G., Bison, G., Bodek, K., Бондар, В. М., Bouillaud, T., Clément, B., Chanel, E., Chiu, P.-J., Crawford, C., et al. (2022) · Review of Scientific Instruments · doi:10.1063/5.0130257 · Cited by 1
Biomagnetic sensing: technologies and applications
Guo, H., Wu, T., Sun, C., Zhao, B., & Yang, X. (2024) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2024-1029 · Cited by 1
Kotani, M., Mori, H., Kuriki, S., Uchikawa, Y., Chiyotani, K., & Nemoto, I. (1987) · Springer eBooks · doi:10.1007/978-94-009-3361-3_20 · Cited by 1
Development of a passive MEG stimulus for measurement of the binaural masking level difference
Gascoyne, L. E. (2015) · Aston Publications Explorer (Aston University) · doi:10.48780/publications.aston.ac.uk.00025259 · Cited by 1
Analog and Digital SQUID Sensors
Radparvar, M. (2002) · Wiley eBooks · doi:10.1002/0471443395.img092 · Cited by 1
Transdutor híbrido para medidas susceptométricas e ultrassônicas simultaneamente
Bruno, A. C. (2010) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.59.2010.tde-15042010-082441 · Cited by 1
Advanced Source Reconstruction and Volume Conductor Modeling for Fetal Magnetocardiography
Tao, R. (2015) · KU ScholarWorks (The University of Kansas) · Cited by 1
Discussion of Estimating Multiple Sources Based on Three- Dimensional Magnetocardiograms Measurement
Liu, M., & Uchikawa, Y. (2011) · Procedia Environmental Sciences · doi:10.1016/j.proenv.2011.10.064 · Cited by 1
Giesler, T., Pohle, K., Flüg, M., Achenbach, S. S., Klinghammer, L., Moshage, W. E. L., & Daniel, W. G. (2009) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1998.43.s1.230 · Cited by 1
Numerical methods for improved signal to noise ratios in spatiotemporal biomedical data
Paolo, D. D.-I. D. P. (2010) · Common Library Network (Der Gemeinsame Bibliotheksverbund) · Cited by 1
Design and development of a 19 channel SQUID magnetometer system
Hirata, Y., Kuriki, S., Nakayama, S., Chinone, K., Ataka, T., Ikeda, K., & Kamioka, Y. (2002) · Conference proceedings - IEEE Instrumentation/Measurement Technology Conference · doi:10.1109/imtc.1994.351800 · Cited by 1
Bioelectric and Biomagnetic Measurements
(2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470546352.ch35 · Cited by 1
Yamazaki, K., Fujiwara, K., Kondo, T., & Inamoto, Y. (1998) · IEEJ Transactions on Fundamentals and Materials · doi:10.1541/ieejfms1990.118.5_453 · Cited by 1
Clinical Value of Magnetocardiographic Mapping
Nakaya, Y., Mori, H., & Nomura, M. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_86 · Cited by 1
Nowak, H. (2015) · Wiley eBooks · doi:10.1002/3527600434.eap761 · Cited by 1
Measurement of Tangential Componet of Magnetocardiogram in Normal Subjects
Noda, Y., Mitsui, T., Terada, Y., Tsukada, K., Haruta, Y., & Yoshida, T. (1995) · JAPANES JOURNAL OF MEDICAL INSTRUMENTATION · doi:10.4286/ikakikaigaku.65.5_233 · Cited by 1
Biomagnetometry is warming up from liquid helium to room temperature
Nakasato, N. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.07.007 · Cited by 1
研究会 第36回理論心電図研究会 テーマ : 心臓電気現象記録法の原理と臨床応用 心磁図の原理
啓二, 塚., 明彦, 神., 宮下, 豪., さつき, 山., 仁志, 堀., 康, 寺., 利夫, 三., & 巖, 山. (2001) · 心臓 · doi:10.11281/shinzo1969.33.5_423 · Cited by 1
Metrology for electromagnetic technology : a bibliography of NBS publications
Kamper, R. A. (1980) · doi:10.6028/nbs.ir.79-1625 · Cited by 1
DESENVOLVIMENTO E CARACTERIZAÇÃO DE GRADIÔMETRO GMI DE ALTA SENSIBILIDADE
Riveros, P. A. D. (2017) · doi:10.17771/pucrio.acad.32032 · Cited by 1
極低周波微小磁界振動に対するパーマロイを用いた磁気シールド効果に関する研究
榊原, 満. (2022) · Institutional Repositories DataBase (IRDB) · Cited by 1
Magnetocardiography at the Turn of the Millenium
Hombach, V., & Scharf, B. (2000) · Developments in cardiovascular medicine · doi:10.1007/978-94-011-4090-4_39
Biomagnetism: A Non-Invasive New Approach for Imaging of Bioelectrical Sources in the Human Body
Romani, G. L., & Leoni, R. (1987) · Springer eBooks · doi:10.1007/978-94-009-3537-2_32
Magnetism and Magnetobiology: New Undiscovered Horizons?
Pavlović, M. D. (2014) · Springer eBooks · doi:10.1007/978-3-319-10798-1_22
Lehto, M. (2009) · Helda - University of Helsinki Institutional Repository
Development of high resolution SQUID magnetometer for biomagnetic measurement
KOBAYASHI, K., & Uchikawa, Y. (2004) · IEEE International Magnetics Conference · doi:10.1109/intmag.2003.1230740
Mapping of Human Heart Beat Dynamics by Atomic Magnetometers
Weis, A. (2005) · AIP conference proceedings · doi:10.1063/1.1928871
First Results for a Superconducting Imaging-Surface Sensor Array for Magnetocardiography
Kraus, R. H., Flynn, E. R., Espy, Matlachov, A. N., Overton, W. C., Wood, C. C., Peters, M., & Ruminer, P. (1998) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)
Functional neuroimaging of the somatosensory system with Ultra-high-field fMRI and MEG
Wang, F. (2012) · Nottingham ePrints (University of Nottingham)
Anatomy of the Cardiovascular Apparatus
Thiriet, M. (2013) · Biomathematical and biomechanical modeling of the circulatory and ventilatory systems · doi:10.1007/978-1-4614-9469-0_1
Metadata
- Authors
- Cohen, D., Edelsack, E. A., & Zimmerman, J. E.
- Affiliations
- Massachusetts Institute of Technology (US)
- Office of Naval Research (US)
- Philco-Ford (United States) (US)
- ORCID
- Cohen, David
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1970-04-01
- Volume
- 16
- Issue
- 7
- Pages
- 278-280
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2055429396
- Cited by
- 361
- References
- 6
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 9 · 2021: 5 · 2020: 9 · 2019: 8 · 2018: 8 · 2017: 5 · 2016: 2 · 2015: 4 · 2014: 8 · 2013: 13 · 2012: 7
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, SQUID magnetometer, superconducting magnetometer, cardiac magnetic field, magnetic shielding, noise sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.