MAGNETOCARDIOGRAMS TAKEN INSIDE A SHIELDED ROOM WITH A SUPERCONDUCTING POINT-CONTACT MAGNETOMETER
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A point-contact (SQUID) magnetometer was used inside a shielded room to record the magnetic field of the human heart, without noise-averaging. The resulting magnetocardiograms, with the peak signal at about 3 × 10−7 G had a noise level of about 1 × 10−9 G (rms, per root cycle). They approach good medical electrocardiograms in clarity, and are an order-of-magnitude improvement in sensitivity over previous magnetic detectors of the heart. These results suggest new medical uses for this magnetometer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“finally providing an experimental setup and a magnetic signal-to-noise ratio (SNR) suitable for recording cardiac and even brain biomagnetic signals (13, 14).”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [13]
Citations
Cites
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Self-citationDetection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Quantum States and Transitions in Weakly Connected Superconducting Rings
Silver, A. H., & Zimmerman, J. E. (1967) · Physical Review · doi:10.1103/physrev.157.317 · Cited by 309
Self-citationMagnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
Self-citationTheory of Magnetic Detection of the Heart's Electrical Activity
Baule, G., & McFee, R. (1965) · Journal of Applied Physics · doi:10.1063/1.1714404 · Cited by 112
Measurements and a Simplified Interpretation of Magnetocardiograms from Humans
COHEN, D., & CHANDLER, L. (1969) · Circulation · doi:10.1161/01.cir.39.3.395 · Cited by 50
Self-citation
Cited by
Items 101–200 of 406
Lee, Y. H., Yu, K. K., Kim, J. M., Kwon, H.-C., & Kim, K. (2009) · Superconductor Science and Technology · doi:10.1088/0953-2048/22/11/114003 · Cited by 21
Magnetic measurements of peripheral nerve function using a neuromagnetic current probe
Wijesinghe, R. S. (2010) · Experimental Biology and Medicine · doi:10.1258/ebm.2009.009306 · Cited by 21
Forty Years of Magnetocardiology
Stroink, G. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-12197-5_1 · Cited by 21
Clinical aspects of biological fields: an introduction for health care professionals
Oschman, J. L. (2002) · Journal of Bodywork and Movement Therapies · doi:10.1054/jbmt.2001.0259 · Cited by 21
Electric field and potential calculation for a bioelectric current dipole in an ellipsoid
Irimia, A. (2005) · Journal of Physics A Mathematical and General · doi:10.1088/0305-4470/38/37/012 · Cited by 20
Extracorporeal magnetic fields generated by internal bioelectric sources
Geselowitz, D. A., & Miller, W. (1973) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1973.1067660 · Cited by 20
Applications of SQUID Magnetometers to Biomagnetism and Nondestructive Evaluation
Wikswo, J. P. (2000) · Springer eBooks · doi:10.1007/978-94-017-0752-7_3 · Cited by 20
High-Tc SQUIDs: the ultra sensitive sensors for non-destructive testing and biomagnetism
Mahdi, A. E., & Mapps, D. J. (2000) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(99)00122-3 · Cited by 20
HTS DC SQUIDs for practical applications
Daalmans, G. (1995) · Applied Superconductivity · doi:10.1016/0964-1807(96)85903-5 · Cited by 20
Discrete spatial filtering with SQUID gradiometers in biomagnetism
Bruno, A. C., Ribeiro, P. C., von der Weid, J. P., & Symko, O. G. (1986) · Journal of Applied Physics · doi:10.1063/1.337008 · Cited by 20
A Study of the Vector Magnetocardiographic Waveform
Rosen, A., & Inouye, G. T. (1975) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1975.324556 · Cited by 20
Kaufman, L., Okada, Y. C., TRIPP, J., & Weinberg, H. (1984) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1984.tb23596.x · Cited by 20
KOBAYASHI, K., Uchikawa, Y., Yamazaki, K., & Yamada, Y. (1998) · IEEJ Transactions on Sensors and Micromachines · doi:10.1541/ieejsmas.118.524 · Cited by 20
Exploring Biomagnetism for Inclusive Vital Sign Monitoring: Modeling and Implementation
Guo, X., Tan, L., Chen, T., Gu, C., Shu, Y., He, S., He, Y., Chen, J., & Shangguan, L. (2024) · ACM Annual International Conference on Mobile Computing and Networking (MobiCom) · doi:10.1145/3636534.3649349 · Cited by 19
Synchronous recording of magnetocardiographic and electrocardiographic signals
Pȩczalski, K., Sobiech, J., Buchner, T., Kornack, T. W., Foley, E. L., Janczak, D., Jakubowska, M., Newby, D. E., Ford, N., & Zajdel, M. (2024) · Scientific Reports · doi:10.1038/s41598-024-54126-5 · Cited by 18
Recent developments in the measurement of magnetic fields from isolated nerves and muscles (invited)
Wikswo, J. P. (1981) · Journal of Applied Physics · doi:10.1063/1.328998 · Cited by 17
Ultra low noise all niobium DC-SQUIDs
Daalmans, G., Bär, L., Bömmel, F., Kress, R., & Uhl, D. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133841 · Cited by 17
Four-channel miniaturized SERF magnetometer with spatial inhomogeneous atomic polarization
Liang, Z., Zhang, Y., Long, T., Li, B., Hu, J., Zhou, P., Liu, L., Hu, G., Ye, M., & Wang, Y. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.112013 · Cited by 16
Development of a high spatial resolution SQUID magnetometer for biomagnetic measurement
KOBAYASHI, K., & Uchikawa, Y. (2003) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2003.816156 · Cited by 16
Magnetic Recordings of the Heart's Electrical Activity with a Cryogenic Magnetometer
Rosen, A., Inouye, G. T., Morse, A., & Judge, D. L. (1971) · Journal of Applied Physics · doi:10.1063/1.1659669 · Cited by 16
Hämäläinen, M. S., & Nenonen, J. T. (1999) · Wiley Encyclopedia of Electrical and Electronics Engineering · doi:10.1002/047134608x.w4707 · Cited by 16
Single-Beam Miniaturized Atomic Magnetometer With Square-Wave Modulation for Magnetoencephalography
Ding, Z., Han, B., & Tang, J. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3043947 · Cited by 15
Measurement of Magnetic Field Produced from the Human Body
Uchikawa, Y., & Kotani, M. (1992) · IEEE Translation Journal on Magnetics in Japan · doi:10.1109/tjmj.1992.4565462 · Cited by 15
Donaldson, G. B. (1989) · Springer eBooks · doi:10.1007/978-3-642-83885-9_7 · Cited by 15
Principles and Applications of SQUID Sensors
Katila, T. E. (1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1_2 · Cited by 15
Active stabilization of terrestrial magnetic field with potassium atomic magnetometer
Ding, Y., Zhang, R., Zheng, J., Chen, J., Peng, X., Wu, T., & Guo, H. M. (2022) · Review of Scientific Instruments · doi:10.1063/5.0073636 · Cited by 14
Respiratory Magnetogram Detected with a MEMS Device
Domínguez-Nicolás, S. M., Juárez-Aguirre, R., Herrera‐May, A. L., Garcia-Ramirez, P. J., Figueras, E., Gutiérrez-D, E. A., Tapia, J. A., Trejo, A., & Manjarrez, E. (2013) · International Journal of Medical Sciences · doi:10.7150/ijms.4732 · Cited by 13
Grossräumige magnetische abschirmungen
Mager, A. (1975) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(75)90129-8 · Cited by 13
Isomagnetic maps in right ventricular overloading
Nakaya, Y., Takeuchi, A., Nii, H., Katayama, M., Nomura, M., Fujino, K., Saito, K., & Mori, H. (1988) · Journal of Electrocardiology · doi:10.1016/s0022-0736(88)80013-x · Cited by 13
Features of a Wall With Open-Type Magnetic Shielding Method
Saito, T. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2002771 · Cited by 13
Horigome, H., Tsukada, K., Kandori, A., Shiono, J., Matsui, A., Terada, Y., & Mitsui, T. (1999) · International journal of cardiac imaging · doi:10.1023/a:1006136525382 · Cited by 13
Three-dimensional spectral map of atrial fibrillation by a 64-channel magnetocardiogram
Nakai, K., Oka, T., Okabayashi, H., Tsuboi, J., Fukuhiro, Y., Fukushima, A., Suwabe, A., Itoh, M., & Yoshizawa, M. (2008) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2007.06.008 · Cited by 12
Stroink, G. (1989) · Advances in Biomagnetism · doi:10.1007/978-1-4613-0581-1_4 · Cited by 12
System for Nature-inspired Signal Processing: Principles and Practice
Ekpar, F. E. (2019) · European Journal of Electrical Engineering and Computer Science · doi:10.24018/ejece.2019.3.6.154 · Cited by 12
MagWear: Vital Sign Monitoring Based on Biomagnetism Sensing
Guo, X., Tan, L., Gu, C., Shu, Y., He, S., & Chen, J. (2024) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2024.3452499 · Cited by 12
Pl, A., Göranson, H., Hindmarsh, T., KNUTSSON, E., Mohlkert, D., Rosenqvist, M., & Bergfeldt, L. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712138 · Cited by 12
Papanicolaou, A. C., & Tarkka, I. M. (1996) · Springer eBooks · doi:10.1007/978-1-4899-1701-0_8 · Cited by 12
Magnetocardiographic P waves in normal subjects and patients with mitral stenosis.
Sumi, M., Takeuchi, A., Katayama, M., FUKUDA, Y., NOMURA, M., Fujino, K., Murakami, M., Nakaya, Y., & Mori, H. (1986) · Japanese Heart Journal · doi:10.1536/ihj.27.621 · Cited by 12
Uchida, S., Iramina, K., Goto, K., & Ueno, S. (1999) · IEEE Transactions on Magnetics · doi:10.1109/20.800776 · Cited by 12
Tolstrup, K., Akhtari, M., Brisinda, D., Meloni, A. M., Siegel, R. J., & Fenici, R. (2024) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2024.100483 · Cited by 11
Magnetic Field Imaging for non destructive 3D IC testing
Gaudestad, J. O., & Orozco, A. (2014) · Microelectronics Reliability · doi:10.1016/j.microrel.2014.07.080 · Cited by 11
The P wave in the magnetocardiogram
Takeuchi, A., Watanabe, K., Nomura, M., Ishihara, S., Sumi, M., Murakami, M., Saito, K., Nakaya, Y., & Mori, H. (1988) · Journal of Electrocardiology · doi:10.1016/s0022-0736(88)80012-8 · Cited by 11
Zhang, T., & Okada, Y. C. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.12.022 · Cited by 11
Kandori, A., Miyashita, T., Suzuki, D., Yokosawa, K., & Tsukada, K. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/2/403 · Cited by 11
Development of an optical cardio-magnetometer
Bison, G. (2004) · reroDoc Digital Library · Cited by 10
Williamson, S. J., Kaufman, L., & Brenner, D. A. (1977) · Springer eBooks · doi:10.1007/978-1-4684-2805-6_8 · Cited by 10
Medical applications of magnetism
Frei, E. H. (1970) · C R C Critical Reviews in Solid State Sciences · doi:10.1080/10408437008243423 · Cited by 10
High-field magnets and high-field superconductors
Foner, S. (1995) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.402512 · Cited by 10
Clinical value of magnetocardiography
Fenici, R., Masselli, M., Lopez, L., & Melillo, G. (1989) · Developments in cardiovascular medicine · doi:10.1007/978-94-009-1081-2_19 · Cited by 10
Brisinda, D., Caristo, M. E., & Fenici, R. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/8/002 · Cited by 9
Hybrid system for magnetic and acoustic measurement
Bruno, A. C., Baffa, O., & Carneiro, A. A. O. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334067 · Cited by 9
Ohkubo, M. (2023) · Review of Scientific Instruments · doi:10.1063/5.0167372 · Cited by 9
Mäkijärvi, M. A., Korhonen, P., Jurkko, R., Väänänen, H., SILTANEN, P., & Hänninen, H. (2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3_44 · Cited by 9
Large-Volume, Magnetically Shielded Room
Scott, G. R., & Frohlich, C. (1985) · Topics in geobiology · doi:10.1007/978-1-4613-0313-8_8 · Cited by 9
Model studies of electric and magnetic fields of the heart
Geselowitz, D. B. (1973) · Journal of the Franklin Institute · doi:10.1016/0016-0032(73)90292-5 · Cited by 9
Barbanera, S., Carelli, P., Modean, I., & Romani, G. L. (1978) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/11/4/005 · Cited by 9
FEA simulations for low-frequency multi-layer magnetically shielded rooms
Yang, S., Zhang, X., Gao, J., Liu, Y., Zhang, J., & Xi, X. (2022) · AIP Advances · doi:10.1063/5.0093443 · Cited by 8
Current Status and Future of Cardiac Mapping in Atrial Fibrillation
Ds, K., & Ah, H. (2012) · InTech eBooks · doi:10.5772/25905 · Cited by 8
Gu, H.-F., Cai, W.-Y., Yu-ke, W., Liu, Z., Wang, Q., Wang, Y., Dai, Y.-D., & Ma, P. (2012) · Chinese Physics B · doi:10.1088/1674-1056/21/4/040702 · Cited by 8
3D Magnetic Field Reconstruction Methodology Based on a Scanning Magnetoresistive Probe
Richheimer, F., Costa, M., Leitão, D. C., Gaspar, J., Cardoso, S., & Freitas, P. P. (2018) · Sensors · doi:10.3390/s18072049 · Cited by 8
Biomagnetism: an application of superconductivity
Carelli, P., & Pizzella, V. (1992) · Superconductor Science and Technology · doi:10.1088/0953-2048/5/7/001 · Cited by 8
Caiani, G., Chiaramello, E., Ravazzani, P., & Fiocchi, S. (2026) · Bioelectronic Medicine · doi:10.1186/s42234-025-00198-1 · Cited by 7
Biomagnetic techniques for evaluating gastric emptying, peristaltic contraction and transit time
la Roca-Chiapas, J. M. D., & Córdova–Fraga, T. (2011) · World Journal of Gastrointestinal Pathophysiology · doi:10.4291/wjgp.v2.i5.65 · Cited by 7
Rosen, A., Inouye, G. T., Morse, A., & Judge, D. L. (1972) · Journal of Applied Physics · doi:10.1063/1.1661415 · Cited by 7
Magnetocardiography in weak dc ambient magnetic fields
Boismier, G., Hlatky, L., & Tepley, N. (1979) · Journal of Applied Physics · doi:10.1063/1.326259 · Cited by 7
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Biomagnetic Signatures of Gastrointestinal Electrical Activity
Bradshaw, L. A., Kim, J., Cheng, L. K., & Richards, W. O. (2013) · Lecture notes in computational vision and biomechanics · doi:10.1007/978-94-007-6561-0_9 · Cited by 6
Characteristic parameters of electromagnetic signals from a human heart system
Liu, X., Pei, L., Yin, W., Zhang, S., Gao, H.-L., & Dai, Y.-D. (2011) · Chinese Physics B · doi:10.1088/1674-1056/20/4/047401 · Cited by 6
Kautz, R. L. (2001) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.919524 · Cited by 6
Reconstruction of the Electrical Structure of the Human Body Using Spectral Functional Tomography
Rykunov, S. D., Boyko, A. I., & Ustinin, M. N. (2023) · Pattern Recognition and Image Analysis · doi:10.1134/s1054661823040387 · Cited by 6
Special article Magnetocardiography in clinical cardiology. Status quo and future applications
Leithäuser, B., Jung, F., & Park, J. (2011) · Advances in Interventional Cardiology · doi:10.5114/pwki.2011.24739 · Cited by 6
Gao, J., Tao, Y., Ping, M., & Yuan-Dong, D. (2010) · Acta Physica Sinica · doi:10.7498/aps.59.5044 · Cited by 6
Krause, H., & Dong, H. (2017) · Springer series on chemical sensors and biosensors · doi:10.1007/5346_2017_13 · Cited by 6
Proposal for a Plasmonic Mach–Zehnder Modulator Utilizing Quantum Interference Effect
Morimoto, M. (2013) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2013.2282255 · Cited by 6
An approach to clinical magnetocardiology.
AWANO, I., MURAMOTO, A., & Awano, N. (1982) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.138.367 · Cited by 6
Two-dimensional mapping of impedance magnetocardiograms
Kandori, A., Miyashita, T., Suzuki, D., Yokosawa, K., & Tsukada, K. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1010856 · Cited by 6
Event Related Brain Electrical and Magnetic Activity: Toward Predicting on-job Performance
Lewis, G. W. (1983) · International Journal of Neuroscience · doi:10.3109/00207458308987360 · Cited by 6
A mesoscopic spectrometer based on the Josephson effect
Griesmar, J. (2018) · theses.fr (ABES) · doi:10.70675/1c6a9249z1d96z481az8ff4z73afb3e9b0ad · Cited by 6
Universal reconstruction of complex magnetic profiles with minimal prior assumptions
Yao, C., Yu, Y., Shi, Y., Jung, J., Váci, Z., Wang, Y., Liu, Z., Zhang, C., Tikoo-Schantz, S. M., & Zu, C. (2025) · Physical Review Applied · doi:10.1103/q312-kf83 · Cited by 5
Distributed current source reconstruction of magnetocadiography and its accuracy analysis
Wang, W., Chen, Z., Yu-Zhang, L., Zhang, S., Xie, X., & Shi-Qin, J. (2013) · Acta Physica Sinica · doi:10.7498/aps.62.148703 · Cited by 5
Basic Technology and Clinical Application Technique of Magnetocardiograph
Kandori, A. (2005) · IEEJ Transactions on Fundamentals and Materials · doi:10.1541/ieejfms.125.81 · Cited by 5
The Commercialization of SQUIDs
Fagaly, R. L. (2014) · IEEE Transactions on Applied Superconductivity · doi:10.1109/tasc.2014.2364212 · Cited by 5
Impact of SQUIDs on functional imaging in neuroscience
Penna, S. D., Pizzella, V., & Romani, G. L. (2014) · Superconductor Science and Technology · doi:10.1088/0953-2048/27/4/044004 · Cited by 5
Right ventricular volume unloading evaluated by tangential magnetocardiography
Terada, Y., Mitsui, T., Sato, M., Horigome, H., & Tsukada, K. (2000) · The Japanese Journal of Thoracic and Cardiovascular Surgery · doi:10.1007/bf03218080 · Cited by 5
A high-Tc dc-SQUID-based single-channel MCG and its per-formance
Wang, H. (2002) · Chinese Science Bulletin · doi:10.1360/02tb9406 · Cited by 5
First results for a novel superconducting imaging-surface sensor array
Kraus, R. H., Flynn, E. R., Espy, M. A., Matlashov, A. N., Overton, W. C., Peters, M. V., & Ruminer, P. (1999) · IEEE Transactions on Applied Superconductivity · doi:10.1109/77.783643 · Cited by 5
Magnetocardiac signal analysis based on multiple time windows beamformer method
Wei-Yuan, W., Shi-Qin, J., Da-Fang, Z., Jia-Chen, Z., Yu-Rui, Y., & Wei-wei, Q. (2014) · Acta Physica Sinica · doi:10.7498/aps.63.248702 · Cited by 5
Chaikovsky, I. A., Прімін, М. А., & Kazmirchuk, A. P. (2021) · Visnik Nacional noi academii nauk Ukrai ni · doi:10.15407/visn2021.02.033 · Cited by 5
Chaikovsky, I. A. (2006) · DuEPublico (University of Duisburg-Essen) · Cited by 5
Characteristics of magnetocardiography and electrocardiography in the time-frequency domain
Liu, X., Pei, L., Zhang, S., Yin, W., & Dai, Y.-D. (2011) · Chinese Science Bulletin · doi:10.1007/s11434-010-4066-7 · Cited by 5
An Economical Magnetocardiogram System Based on High- T c SQUIDs
Li, Z., Xue-Min, Z., Li-hua, Z., Xu-guang, H., Ren, Y.-F., Geng-Hua, C., Yang, Q., & Ji, F. (2006) · Chinese Physics Letters · doi:10.1088/0256-307x/23/8/097 · Cited by 5
A SQUID gradiometer module with large junction shunt resistors
Qiu, Y., Liu, C., Zhang, S., Zhang, G., Wang, Y., Li, H., Zeng, J., Kong, X., & Xie, X. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/8/088503 · Cited by 5
What is ‘healing energy’? Part 2: measuring the fields of life
Oschman, J. L. (1997) · Journal of Bodywork and Movement Therapies · doi:10.1016/s1360-8592(97)80013-7 · Cited by 5
Magnetocardiography Throws Its Hat in the Ring
Steinberg, J. S., & Levitt, H. L. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00418.x · Cited by 5
Ilmoniemi, R. J. (1994) · Elsevier eBooks · doi:10.1016/b978-0-12-160262-8.50008-6 · Cited by 5
Electric and Magnetic Shielding with Superconductors
Cabrera, B., & Hamilton, W. O. (1973) · Springer eBooks · doi:10.1007/978-1-4615-8978-5_7 · Cited by 5
Chaikovsky, I. A., Kazmirchyk, A., Sofienko, S., Liu, Y.-B., Zhou, Y.-F., Feng, X., Xu, L., & Huang, Y. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.104924 · Cited by 4
Experience with a multichannel system for biomagnetic study
Schneider, S., Abraham‐Fuchs, K., Reichenberger, H., Seifert, H., Hoenig, H. E., & Röhrlein, G. (1993) · Physiological Measurement · doi:10.1088/0967-3334/14/4a/010 · Cited by 4
Hat die Magnetokardiografie eine klinische Zukunft?
Esperer, H.-D. (1997) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/bf03042618 · Cited by 4
Calculation of the magnetic field due to a bioelectric current dipole in an ellipsoid
Irimia, A. (2008) · Applications of Mathematics · doi:10.1007/s10492-008-0016-y · Cited by 4
Metadata
- Authors
- Cohen, D., Edelsack, E. A., & Zimmerman, J. E.
- Affiliations
- Massachusetts Institute of Technology (US)
- Office of Naval Research (US)
- Philco-Ford (United States) (US)
- ORCID
- Cohen, David
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1970-04-01
- Volume
- 16
- Issue
- 7
- Pages
- 278-280
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2055429396
- Cited by
- 361
- References
- 6
- Citations by year
- 2026: 7 · 2025: 6 · 2024: 9 · 2023: 6 · 2022: 9 · 2021: 5 · 2020: 9 · 2019: 8 · 2018: 8 · 2017: 5 · 2016: 2 · 2015: 4 · 2014: 8 · 2013: 13 · 2012: 7
- FWCI
- 14.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Keywords
- magnetocardiography, SQUID magnetometer, superconducting magnetometer, cardiac magnetic field, magnetic shielding, noise sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.