The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Molecular Beams of Macroions
Abstract
By means of electrospraying a dilute polymer solution into an evaporation chamber, negative macroions can be produced and a molecular beam formed by sampling the gaseous mixture of macroions, solvent, and nitrogen molecules with a nozzle-skimmer system of the Kantrowitz–Gray type. The macroion current can be detected by a Faraday cage after the light ions have been repelled from the beam by negative voltages on a repeller grid. Theoretical repeller voltages which best agree with the observed are those calculated by assuming a macroion velocity within 2% of the estimated supersonic beam velocity of 743 m sec−1. Polystyrene macroions of 51 000 weight-average amu tend to form dimers and trimers in the beam while larger polystyrene macroions of 411 000 weight-average amu appear mostly to be multiply charged single species. The results demonstrate that definite mass/charge states can be formed by the electrospray technique, that a considerable monochromatization of macroion velocities in the beam takes place, and that the macroions become highly concentrated relative to low-molecular-weight solvent and nitrogen ions during the transit time in the supersonic beam.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
XX. On the equilibrium of liquid conducting masses charged with electricity
Rayleigh, L. (1882) · The London, Edinburgh, and Dublin Philosophical Magazine and Journal of Science · doi:10.1080/14786448208628425 · Cited by 1,825
Velocity Distributions in Molecular Beams from Nozzle Sources
Anderson, J. B., & Fenn, J. B. (1965) · The Physics of Fluids · doi:10.1063/1.1761320 · Cited by 458
Theory of Gel—Dose Curves for Polymers Undergoing Simultaneous Crosslinking and Scission
Saitô, O., Kang, H., & Ḋole, M. (1967) · The Journal of Chemical Physics · doi:10.1063/1.1841265 · Cited by 65
The direct observation of polymer molecules and determination of their molecular weight
Richardson, M. J. (1964) · Proceedings of the Royal Society of London A Mathematical and Physical Sciences · doi:10.1098/rspa.1964.0089 · Cited by 48
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Rapid identification of proteins by peptide-mass fingerprinting
Pappin, D. J. C., Hojrup, P., & Bleasby, A. J. (1993) · Current Biology · doi:10.1016/0960-9822(93)90195-t · Cited by 1,615
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Electrospray interface for liquid chromatographs and mass spectrometers
Whitehouse, C. M., Dreyer, R. N., Yamashita, M., & Fenn, J. B. (1985) · Analytical Chemistry · doi:10.1021/ac00280a023 · Cited by 1,512
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Dongré, A. R., Jones, J. L., Somogyi, Á., & Wysocki, V. H. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9542193 · Cited by 894
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Unraveling the Mechanism of Electrospray Ionization
Konermann, L., Ahadi, E., Rodriguez, A. D., & Vahidi, S. (2013) · Analytical Chemistry · doi:10.1021/ac302789c · Cited by 735
Definitions of terms relating to mass spectrometry (IUPAC Recommendations 2013)
Murray, K. K., Boyd, R. K., Eberlin, M. N., Langley, G. J., Li, L., & Naito, Y. (2013) · Pure and Applied Chemistry · doi:10.1351/pac-rec-06-04-06 · Cited by 687
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Charge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Electrospray Wings for Molecular Elephants (Nobel Lecture)
Fenn, J. B. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200300605 · Cited by 642
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
Fernandez de la Mora, J. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00601-7 · Cited by 528
Ion formation from charged droplets: Roles of geometry, energy, and time
Fenn, J. B. (1993) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(93)85014-o · Cited by 518
Orbitrap mass spectrometry: Instrumentation, ion motion and applications
Perry, R. H., Cooks, R. G., & Noll, R. J. (2008) · Mass Spectrometry Reviews · doi:10.1002/mas.20186 · Cited by 514
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Mass Spectrometry of Polymers and Polymer Surfaces
Hanton, S. D. (2001) · Chemical Reviews · doi:10.1021/cr9901081 · Cited by 461
Watson, A. D. (2006) · Journal of Lipid Research · doi:10.1194/jlr.r600022-jlr200 · Cited by 455
Mallet, C. R., Lu, Z., & Mazzeo, J. R. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1276 · Cited by 441
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
Enke, C. G. (1997) · Analytical Chemistry · doi:10.1021/ac970095w · Cited by 419
Protein Complexes in the Gas Phase: Technology for Structural Genomics and Proteomics
Benesch, J. L. P., Ruotolo, B. T., Simmons, D. A., & Robinson, C. V. (2007) · Chemical Reviews · doi:10.1021/cr068289b · Cited by 408
Effect of eluent on the ionization process in liquid chromatography–mass spectrometry
Kostiainen, R., & Kauppila, T. J. (2009) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.08.095 · Cited by 402
Mass Spectrometry, Review of the Basics: Electrospray, MALDI, and Commonly Used Mass Analyzers
El-Aneed, A., Cohen, A., & Banoub, J. (2009) · Applied Spectroscopy Reviews · doi:10.1080/05704920902717872 · Cited by 386
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
Droplet Dynamics and Ionization Mechanisms in Desorption Electrospray Ionization Mass Spectrometry
Venter, A., Sojka, P. E., & Cooks, R. G. (2006) · Analytical Chemistry · doi:10.1021/ac0615807 · Cited by 361
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
The Role of Mass Spectrometry in Structure Elucidation of Dynamic Protein Complexes
Sharon, M., & Robinson, C. V. (2007) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.76.061005.090816 · Cited by 357
On the mechanisms by which the charged droplets produced by electrospray lead to gas phase ions
Kebarle, P., & Peschke, M. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00598-x · Cited by 352
Przybylski, M., & Glocker, M. O. (1996) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199608061 · Cited by 351
Influence of Secondary Structure on the Fragmentation of Protonated Peptides
Tsaprailis, G., Nair, H., Somogyi, Á., Wysocki, V. H., Zhong, W., Futrell, J. H., Summerfield, S. G., & Gaskell, S. J. (1999) · Journal of the American Chemical Society · doi:10.1021/ja982980h · Cited by 350
Liquid chromatography/atmospheric pressure ionization–mass spectrometry in drug metabolism studies
Kostiainen, R., Kotiaho, T., Kuuranne, T., & Auriola, S. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.481 · Cited by 349
Wyttenbach, T., & Bowers, M. T. (2011) · The Journal of Physical Chemistry B · doi:10.1021/jp206867a · Cited by 346
Internal energy and fragmentation of ions produced in electrospray sources
Gabelica, V., & Pauw, E. D. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20027 · Cited by 338
Mechanism of Charging and Supercharging Molecules in Electrospray Ionization
Iavarone, A. T., & Williams, E. R. (2003) · Journal of the American Chemical Society · doi:10.1021/ja021202t · Cited by 324
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Estimates of Protein Surface Areas in Solution by Electrospray Ionization Mass Spectrometry
Kaltashov, I. A., & Mohimen, A. (2005) · Analytical Chemistry · doi:10.1021/ac050511+ · Cited by 319
Robinson, C. V., Chung, E. W., Kragelund, B. B., Knudsen, J., Aplin, R. T., Poulsen, F. M., & Dobson, C. M. (1996) · Journal of the American Chemical Society · doi:10.1021/ja960211x · Cited by 313
Principles of Electrospray Ionization
Wilm, M. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009407 · Cited by 311
Smith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
Cluster–surface interaction: From soft landing to implantation
Popok, V. N., Barke, I., Campbell, E. E. B., & Meiwes-Broer, K.-H. (2011) · Surface Science Reports · doi:10.1016/j.surfrep.2011.05.002 · Cited by 278
Effect of reducing disulfide-containing proteins on electrospray ionization mass spectra
Loo, J. A., Edmonds, C. G., Udseth, H. R., & Smith, R. D. (1990) · Analytical Chemistry · doi:10.1021/ac00206a009 · Cited by 274
State-of-the-art in liquid chromatography–mass spectrometry
Niessen, W. M. A. (1999) · Journal of Chromatography A · doi:10.1016/s0021-9673(99)00480-x · Cited by 267
Electrospray Ionization High-Field Asymmetric Waveform Ion Mobility Spectrometry−Mass Spectrometry
Purves, R. W., & Guevremont, R. (1999) · Analytical Chemistry · doi:10.1021/ac981380y · Cited by 265
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
Schnier, P. D., Gross, D. S., & Williams, E. R. (1995) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(95)00532-3 · Cited by 258
Of protons or proteins: “A beam's a beam for a' that.” (O.S. Burns)
Meng, C. K., Mann, M., & Fenn, J. B. (1988) · Zeitschrift für Physik D Atoms, Molecules and Clusters · doi:10.1007/bf01384871 · Cited by 254
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Sun, J., Kitova, E. N., Wang, W., & Klassen, J. S. (2006) · Analytical Chemistry · doi:10.1021/ac0522005 · Cited by 160
From QCEIMS to QCxMS: A Tool to Routinely Calculate CID Mass Spectra Using Molecular Dynamics
Koopman, J., & Grimme, S. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00098 · Cited by 80
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45
Metadata
- Authors
- Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1968-09-01
- Volume
- 49
- Issue
- 5
- Pages
- 2240-2249
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W1974732006
- Cited by
- 1,613
- References
- 4
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.