Molecular Beams of Macroions. II
The DOI matches its Crossref record.
Abstract
Using the electrospray technique and nozzle–skimmer system previously described, the influence of polystyrene concentration in the sprayed solution on the magnitude and substructure of the macroion current in the molecular beam has been investigated. Other variables studied include polarity of the beam, needle–nozzle and nozzle–skimmer distances, shape of spray, etc. Attempts to produce isolated macroions in the beam by carrier gas atomization were not successful; operation at reduced pressures and elevated temperatures was not found to be advantageous. In the case of positive macroions the current–repeller-voltage curves had less substructure than in the case of negative beams, and the first stopping potential was more dependent upon the solution concentration, especially when using a relatively large nozzle–skimmer distance. For molecular weights of the polystyrene from 600 to 97 200 the relative macroion positive charge was roughly proportional to the surface area of the macroions, assuming the latter to be spheres and as calculated from the first measured stopping potential. In the case of negative beams the current at zero repeller voltage and at a solution concentration of 2.2 × 10−6 Mw was proportional to the third power of the molecular weight at the lower solute molecular weights, as is predicted for a diffusional charging process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
[21] Electrospray ionization mass spectrometry
Fred Banks, J., & Whitehouse, C. M. (1996) · Methods in Enzymology · doi:10.1016/s0076-6879(96)70023-x · Cited by 522
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
An electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Gordon, M. J., Huang, X., Pentoney, S. L., & Zare, R. N. (1988) · Science · doi:10.1126/science.242.4876.224 · Cited by 295
Smith, R. D., & Light-Wahl, K. J. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220902 · Cited by 288
From QCEIMS to QCxMS: A Tool to Routinely Calculate CID Mass Spectra Using Molecular Dynamics
Koopman, J., & Grimme, S. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.1c00098 · Cited by 80
Mokaddem, M., Gareil, P., Belgaied, J., & Varenne, A. (2009) · ELECTROPHORESIS · doi:10.1002/elps.200800480 · Cited by 45
Metadata
- Authors
- Mack, L. L., Kralik, P., Rheude, A., & Dole, M.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1970-05-15
- Volume
- 52
- Issue
- 10
- Pages
- 4977-4986
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W4254152268
- Cited by
- 156
- References
- 0
- FWCI
- 0.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.