A Shielded Facility for Low-Level Magnetic Measurements
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A facility has been constructed for the detection and measurement of time-varying magnetic fields of ∼10−9 G amplitude, in a bandwidth of 0.5 to 100 000 cps. The facility includes a shielded room and magnetic detector, which now consists of a copper coil, eventually to be cooled in liquid helium, feeding a parametric amplifier; it will initially be used to investigate bioelectric current flow in human heart muscles by mapping the time-varying fields outside the body. The shielded room now has two layers of 0.060 in. Moly-Permalloy, and a third inner layer of 0.19 in. aluminum enclosing a 86 in.×88 in.×88 in. volume will soon be installed. Measured shielding factors are given; at present magnetic ``shaking'' is used to produce a shielding factor of ∼400 in the 0–5 cps range, which rises rapidly with increasing frequency.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“a major milestone in MCG was the invention of the first superconducting quantum interference device (SQUID) (10) and the installation of SQUID within the magnetically shielded room (MSR) of the Massachusetts Institute of Technology (MIT) that radically reduce external electromagnetic interference by at least a factor of about 1,000 (11, 12)”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [11]
Citations
Cites
Design of a room-size magnetic shield
Patton, B. J., & Fitch, J. L. (1962) · Journal of Geophysical Research Atmospheres · doi:10.1029/jz067i003p01117 · Cited by 44
ENHANCEMENT OF FERROMAGNETIC SHIELDING AGAINST LOW-FREQUENCY MAGNETIC FIELDS
Cohen, D. (1967) · Applied Physics Letters · doi:10.1063/1.1754854 · Cited by 38
Self-citationEffect of a Superposed Alternating Field on Apparent Magnetic Permeability and Hysteresis Loss
Spooner, T. (1925) · Physical Review · doi:10.1103/physrev.25.527 · Cited by 20
XXXVI. Observations on the different theories of philosophers to explain the phænomena of combustion
Portal, C. (1803) · The Philosophical Magazine · doi:10.1080/14786440308676258 · Cited by 1
Research works printed but not linked: 3
- 1933, Phil. Mag., 15, 202
- 1915, Verhandl. Deut. Physik. Ges., 17, 369
- 1957, Z. Angew. Phys., 9, 111
Cited by
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Design, construction, and performance of a large-volume magnetic shield
Kelha, V., Pukki, J., Peltonen, R., Penttinen, A., Ilmoniemi, R., & Heino, J. (1982) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1982.1061780 · Cited by 209
Large-volume conventional magnetic shields
Cohen, D. (1970) · Revue de Physique Appliquée · doi:10.1051/rphysap:019700050105300 · Cited by 78
Self-citationClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
“Providing a significant improvement in sensitivity and spatial resolution of MF measurements, a major milestone in MCG was the invention of the first superconducting quantum interference device (SQUID) (10) and the installation of SQUID within the magnetically shielded room (MSR) of the Massachusetts Institute of Tech…”
BackgroundVoigt, J., Knappe-Grüneberg, S., Schnabel, A., Körber, R., & Burghoff, M. (2013) · Metrology and Measurement Systems · doi:10.2478/mms-2013-0021 · Cited by 50
“Mu-metal [8].”
Magnetic shield for wide-bandwidth magnetic measurements for nondestructive testing and biomagnetism
Ma, Y. P., & Wikswo, J. P. (1991) · Review of Scientific Instruments · doi:10.1063/1.1142195 · Cited by 45
Hoenig, H. E., Daalmans, G., Folberth, W., Reichenberger, H., Schneider, S., & Seifert, H. (1989) · Cryogenics · doi:10.1016/0011-2275(89)90154-9 · Cited by 42
A magnetic shielded room designed for magnetoencephalography
Sullivan, G. W., Lewis, P. S., George, J. P., & Flynn, E. R. (1989) · Review of Scientific Instruments · doi:10.1063/1.1141016 · Cited by 30
Okada, Y. C., Shah, B. P., & Huang, J.-C. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.301736 · Cited by 25
Instruments and techniques in paleomagnetism and rock magnetism
Collinson, D. W. (1975) · Reviews of Geophysics · doi:10.1029/rg013i005p00659 · Cited by 23
Special Magnetic Measurement Techniques
Foner, S. (1967) · Journal of Applied Physics · doi:10.1063/1.1709685 · Cited by 23
Detection and Analysis of Magnetic Fields Produced by Bioelectric Currents in Humans
Cohen, D. (1969) · Journal of Applied Physics · doi:10.1063/1.1657527 · Cited by 24
Self-citationGrossräumige magnetische abschirmungen
Mager, A. (1975) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(75)90129-8 · Cited by 13
Fundamentals of Magnetic Measurements
(2011) · Series in sensors · doi:10.1201/b10979-3 · Cited by 11
Medical applications of magnetism
Frei, E. H. (1970) · C R C Critical Reviews in Solid State Sciences · doi:10.1080/10408437008243423 · Cited by 10
Large-Volume, Magnetically Shielded Room
Scott, G. R., & Frohlich, C. (1985) · Topics in geobiology · doi:10.1007/978-1-4613-0313-8_8 · Cited by 9
Review of measurements of magnetic fields produced by natural ion currents in humans
Cohen, D. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066764 · Cited by 11
Self-citationInstrumentation for biomagnetism
Duret, D., & Karp, P. (1983) · Il Nuovo Cimento D · doi:10.1007/bf02455917 · Cited by 8
Optimization of Anisotropic Magnetic Shielding
Goto, E., & Soma, T. (1987) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/temc.1987.304374 · Cited by 7
Tashiro, K. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_1 · Cited by 7
Biomagnetism: an application of superconductivity
Carelli, P., & Pizzella, V. (1992) · Superconductor Science and Technology · doi:10.1088/0953-2048/5/7/001 · Cited by 8
Rosen, A., Inouye, G. T., Morse, A., & Judge, D. L. (1972) · Journal of Applied Physics · doi:10.1063/1.1661415 · Cited by 7
Brisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Pf�tzner, H. (1979) · International Journal of Biometeorology · doi:10.1007/bf01553099 · Cited by 6
Device Photolithography: The Electron Beam Pattern Generator
Samaroo, W. R., Raamot, J., Parry, P. D., & Robertson, G. (1970) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1970.tb02514.x · Cited by 6
A high performance static magnetic shielded room for detecting biomagnetic nanoparticles
Wang, Q., Song, T., Wang, M., & Zhang, G. (2010) · Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC) · doi:10.1109/apemc.2010.5475568 · Cited by 5
Liu, X., Wu, C., Zhang, L., Tong, W., & Zheng, S. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3203456 · Cited by 9
“, aluminum and copper, to prevent the mag- 32 netic permeation of their inner part, following the magnetic 33 field shunt principle and eddy current effect [7].”
BackgroundOpen-Type Magnetic Shield Structure and its Performance
Fujikura, M., Segawa, K., Chikuma, K., Fujisaki, K., Mino, J., 森田, 哲., Saito, T., Hirano, H., & Shinnoh, T. (2008) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2008.2002376 · Cited by 4
“Because the height of the shield body is 3 times as long as the side of the bottom, leakage from the bottom or the top is negligible [4], [12].”
BackgroundSuperconducting instrumentation for biomagnetism
Romani, G. L. (1979) · International Journal of Refrigeration · doi:10.1016/0140-7007(79)90086-0 · Cited by 4
Study of Open-Type Magnetically Shielded Room for MRI
Kamata, K., Tamari, Y., Temma, S., Goto, K., & Yunokuchi, K. (2018) · IEEJ Transactions on Electronics Information and Systems · doi:10.1541/ieejeiss.138.799 · Cited by 2
Shielding Effect of Double-Layered Open-Type Magnetic Shield Structure
Hirano, H., Saito, T., Shinnoh, T., Fujikura, M., & Chikuma, K. (2009) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2009.2022023 · Cited by 1
Study of open‐type magnetically shielded room for MRI
Kamata, K., Tamari, Y., Temma, S., Goto, K., & Yunokuchi, K. (2018) · Electronics and Communications in Japan · doi:10.1002/ecj.12131 · Cited by 1
11. Superconducting Device Technology
(1974) · Methods of experimental physics · doi:10.1016/s0076-695x(08)60184-2 · Cited by 1
Magnetic Shield Refinements For Low Temperature VSLI Packaging
Vance, R. D., & Griffith, W. F. (1983) · Information Display · doi:10.1002/j.2637-496x.1983.tb01627.x · Cited by 1
Ogose, S., Mori, S., & Sekii, T. (2019) · The Open Biomedical Engineering Journal · doi:10.2174/1874120701913010011
Recent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Lu, Y., Li, J., & Zhang, T. (2026) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ae8a63
Metadata
- Authors
- Cohen, D.
- Affiliations
- University of Illinois Chicago (US)
- Corresponding author
- Cohen, David
- ORCID
- Cohen, David
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1967-03-01
- Volume
- 38
- Issue
- 3
- Pages
- 1295-1296
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2071716225
- Cited by
- 38
- References
- 4
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 2 · 2019: 1 · 2018: 2 · 2016: 1 · 2013: 1
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Physics (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Measurements
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- magnetic shielding, time-dependent magnetic field, parametric amplifiers, liquid helium cooling, shielding factor, myocardium
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.