Full correlation from picoseconds to seconds by time-resolved and time-correlated single photon detection
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We present an advanced time-correlated single photon counting (TCSPC) technique that delivers traditional fluorescence correlation (FCS) or cross correlation (FCCS) and fluorescence lifetime data simultaneously. Newly developed electronics allow for detection and registration of single photon events over time periods of hours with picoseconds accuracy. Subsequent software-correlation yields correlation curves covering more than 12 orders of magnitude in time. At the same time, the original data, containing all information accessible by single photon counting techniques, can be analyzed conventionally according to common single molecule fluorescence techniques. Potential applications of the new technique using pulsed or cw laser excitation are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correlation between Photons in two Coherent Beams of Light
BROWN, R. H., & TWISS, R. Q. (1956) · Nature · doi:10.1038/177027a0 · Cited by 2,573
Margittai, M., Widengren, J., Schweinberger, E., Schröder, G. F., Felekyan, S., Haustein, E., König, M., Fasshauer, D., Grubmüller, H., Jahn, R., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2331232100 · Cited by 290
Self-citation
Cited by
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Self-citationFluorescence Correlation Spectroscopy: Novel Variations of an Established Technique
Haustein, E., & Schwille, P. (2007) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.biophys.36.040306.132612 · Cited by 548
Single-Molecule Fluorescence Studies of Protein Folding and Conformational Dynamics
Michalet, X., Weiss, S., & Jäger, M. (2006) · Chemical Reviews · doi:10.1021/cr0404343 · Cited by 525
Efficient coupling of photons to a single molecule and the observation of its resonance fluorescence
Wrigge, G., Gerhardt, I., Hwang, J., Zumofen, G., & Sandoghdar, V. (2008) · Nature Physics · doi:10.1038/nphys812 · Cited by 343
Metadata
- Authors
- Felekyan, S., Kühnemuth, R., Kudryavtsev, V., Sandhagen, C., Becker, W., & Seidel, C. A. M.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2005-07-21
- Volume
- 76
- Issue
- 8
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1981104867
- Cited by
- 155
- References
- 2
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.