CoChat

Thermoreflectance technique to measure thermal effusivity distribution with high spatial resolution

Hatori, Kimihito, Taketoshi, Naoyuki, Baba, Tetsuya, Ohta, Hiromichi · 2005 · Review of Scientific Instruments
Cited by 79

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

We have developed an apparatus to measure thermal effusivity distribution in solid materials with a high spatial resolution better than 10μm by the thermoreflectance technique and the periodic heating method. A metal film sputtered on the surface of a sample is periodically heated by a modulated laser beam. The temperature response is measured by using another thin laser beam as a thermoreflectance signal. The thermal effusivity of the sample is derived from the phase lag of the temperature response from the periodic heating. Measurements of a functionally graded material and a fiber composite material are presented as application examples of this thermal effusivity distribution measurement technique.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2130333

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Hatori, K., Taketoshi, N., Baba, T., & Ohta, H.
Venue
Review of Scientific Instruments
Published
2005-11-01
Volume
76
Issue
11
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2056442944
Cited by
79
References
2
FWCI
5.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.