The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Two-color pump-probe system broadly tunable over the visible and the near infrared with sub-30fs temporal resolution
Abstract
We describe an ultrafast spectroscopy system based on two synchronized noncollinear optical parametric amplifiers (NOPAs). Each NOPA can be independently configured to generate ultrabroadband sub-10fs visible pulses, tunable 15fs visible pulses (500–720nm), tunable 15–30fs near-infrared pulses (900–1500nm), and 15–20fs blue pulses (430–480nm). This system enables to perform pump-probe experiments over nearly two octaves of spectrum with unprecedented temporal resolution. We present application examples highlighting the capability of this instrument to track excited-state dynamics occurring on the sub-100fs time scale: electron transfer in polymer-fullerene blends, intersubband energy relaxation in carbon nanotubes, and internal conversion in carotenoids.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The First Step in Vision: Femtosecond Isomerization of Rhodopsin
Schoenlein, R. W., Peteanu, L. A., Mathies, R. A., & Shank, C. V. (1991) · Science · doi:10.1126/science.1925597 · Cited by 892
Cited by
Coherent ultrafast charge transfer in an organic photovoltaic blend
Falke, S. M., Rozzi, C. A., Brida, D., Maiuri, M., Amato, M., Sommer, E., De Sio, A., Rubio, A., Cerullo, G., Molinari, E., et al. (2014) · Science · doi:10.1126/science.1249771 · Cited by 554
Self-citationVasa, P., Wang, W., Pomraenke, R., Lammers, M., Maiuri, M., Manzoni, C., Cerullo, G., & Lienau, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.340 · Cited by 473
Self-citationMarsh, R. A., Hodgkiss, J. M., Albert-Seifried, S., & Friend, R. H. (2010) · Nano Letters · doi:10.1021/nl9038289 · Cited by 290
Andrea Rozzi, C., Maria Falke, S., Spallanzani, N., Rubio, A., Molinari, E., Brida, D., Maiuri, M., Cerullo, G., Schramm, H., Christoffers, J., et al. (2013) · Nature Communications · doi:10.1038/ncomms2603 · Cited by 282
Self-citationKang, K., Koh, Y. K., Chiritescu, C., Zheng, X., & Cahill, D. G. (2008) · Review of Scientific Instruments · doi:10.1063/1.3020759 · Cited by 209
Metadata
- Authors
- Manzoni, C., Polli, D., & Cerullo, G.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-02-01
- Volume
- 77
- Issue
- 2
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2024689975
- Cited by
- 178
- References
- 1
- FWCI
- 7.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Two-color pump-probe system broadly tunable over the visible and the near infrared with sub-30fs temporal resolution. https://app.cochat.ai/papers/10.1063/1.2167128
- The paper
- Manzoni, C., Polli, D., & Cerullo, G. (2006). Two-color pump-probe system broadly tunable over the visible and the near infrared with sub-30fs temporal resolution. Review of Scientific Instruments. https://doi.org/10.1063/1.2167128
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.