Cited by 209Thermography and Photoacoustic TechniquesLaser-Matter Interactions and ApplicationsSpectroscopy Techniques in Biomedical and Chemical Research

Two-tint pump-probe measurements using a femtosecond laser oscillator and sharp-edged optical filters

Kang, Kwangu, Koh, Yee Kan, Chiritescu, Catalin, Zheng, Xuan, Cahill, David G.·2008·Review of Scientific Instruments

Abstract

We describe a simple approach for rejecting unwanted scattered light in two types of time-resolved pump-probe measurements, time-domain thermoreflectance (TDTR) and time-resolved incoherent anti-Stokes Raman scattering (TRIARS). Sharp edged optical filters are used to create spectrally distinct pump and probe beams from the broad spectral output of a femtosecond Ti:sapphire laser oscillator. For TDTR, the diffusely scattered pump light is then blocked by a third optical filter. For TRIARS, depolarized scattering created by the pump is shifted in frequency by ≈250 cm−1 relative to the polarized scattering created by the probe; therefore, spectral features created by the pump and probe scattering can be easily distinguished.

Integrity signals

Registry

Crossref · 10.1063/1.3020759

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Over the past two decades, TDTR has emerged and evolved as a reliable, powerful, and versatile technique to measure thermal properties of a wide range of bulk and thin film materials and their interfaces.

    “Over the past two decades, ultrafast laser-based time-domain thermoreflectance (TDTR) has emerged and evolved as a reliable, powerful, and versatile technique to measure the thermal properties of a wide range of bulk and thin film materials and their interfaces.”
  • The two-tint and two-color approaches can effectively filter the reflected pump beam but at a significant sacrifice of laser power.

    “Both the two-tint and the two-color approach can effectively filter the reflected pump beam but at a significant sacrifice of the laser power.”
  • The two-tint method has a high demand on laser stability in both intensity and wavelength; otherwise fluctuations in laser wavelength translate into fluctuations in the power intensities of the pump and probe beams and appear as noise in TDTR measurements.

    “In addition, the two-tint method has a high demand on the laser stability in both the intensity and the wavelength (like the one reported in Ref. 23 ). Otherwise, the fluctuations in the laser wavelength would translate into fluctuations in the power intensities of the pump and probe beams and appear as noise in TDTR measurements (like the one reported in Ref. 95 ).”

Cited by

Sorted by citations

Authors
Kang, K., Koh, Y. K., Chiritescu, C., Zheng, X., & Cahill, D. G.
Affiliations
University of Illinois Urbana-Champaign (US)
Venue
Review of Scientific Instruments
Published
2008-11-01
Volume
79
Issue
11
Pages
114901-114901
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2050181169
Cited by
209
References
0
Citations by year
2026: 6 · 2025: 14 · 2024: 11 · 2023: 11 · 2022: 9 · 2021: 17 · 2020: 19 · 2019: 15 · 2018: 17 · 2017: 21 · 2016: 16 · 2015: 5 · 2014: 12 · 2013: 9 · 2012: 12
FWCI
8.01
Type
journal article
Language
en
Open access
closed
Locations
  • Review of Scientific Instruments (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
Keywords
time-domain thermoreflectance, femtosecond Ti:sapphire laser

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review