CoChat

Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system

Open access
Li, Q., Kim, K.-S., Rydberg, A. · 2006 · Review of Scientific Instruments

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

A novel diamagnetic lateral force calibrator (D-LFC) has been developed to directly calibrate atomic force microscope (AFM) cantilever-tip or -bead assemblies. This enables an AFM to accurately measure the lateral forces encountered in friction or biomechanical-testing experiments at a small length scale. In the process of development, deformation characteristics of the AFM cantilever assemblies under frictional loading have been analyzed and four essential response variables, i.e., force constants, of the assembly have been identified. Calibration of the lateral force constant and the “crosstalk” lateral force constant, among the four, provides the capability of measuring absolute AFM lateral forces. The D-LFC is composed of four NdFeB magnets and a diamagnetic pyrolytic graphite sheet, which can calibrate the two constants with an accuracy on the order of 0.1%. Preparation of the D-LFC and the data processing required to get the force constants is significantly simpler than any other calibration methods. The most up-to-date calibration technique, known as the “wedge method,” calibrates mainly one of the two constants and, if the crosstalk effect is properly analyzed, is primarily applicable to a sharp tip. In contrast, the D-LFC can calibrate both constants simultaneously for AFM tips or beads with any radius of curvature. These capabilities can extend the applicability of AFM lateral force measurement to studies of anisotropic multiscale friction processes and biomechanical behavior of cells and molecules under combined loading. Details of the D-LFC method as well as a comparison with the wedge method are provided in this article.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.2209953

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Cited by

See all 208

Metadata

Authors
Li, Q., Kim, K.-S., & Rydberg, A.
Affiliations
Brown University (US)
Venue
Review of Scientific Instruments
Published
2006-06-01
Volume
77
Issue
6
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2029314957
Cited by
208
References
18
Citations by year
2026: 10 · 2025: 11 · 2024: 15 · 2023: 12 · 2022: 10 · 2021: 10 · 2020: 20 · 2019: 10 · 2018: 17 · 2017: 10 · 2016: 9 · 2015: 9 · 2014: 4 · 2013: 4 · 2012: 13
FWCI
5.38
Type
journal article
Language
en
Open access
Licence
Locations
Review of Scientific Instruments (publishedVersion, cc-by)
Funders
Rice University
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
Keywords
atomic force microscopy, diamagnetic levitation, wedge method, friction measurement, Nd-Fe-B permanent magnets, pyrolytic graphite

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.