Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A novel diamagnetic lateral force calibrator (D-LFC) has been developed to directly calibrate atomic force microscope (AFM) cantilever-tip or -bead assemblies. This enables an AFM to accurately measure the lateral forces encountered in friction or biomechanical-testing experiments at a small length scale. In the process of development, deformation characteristics of the AFM cantilever assemblies under frictional loading have been analyzed and four essential response variables, i.e., force constants, of the assembly have been identified. Calibration of the lateral force constant and the “crosstalk” lateral force constant, among the four, provides the capability of measuring absolute AFM lateral forces. The D-LFC is composed of four NdFeB magnets and a diamagnetic pyrolytic graphite sheet, which can calibrate the two constants with an accuracy on the order of 0.1%. Preparation of the D-LFC and the data processing required to get the force constants is significantly simpler than any other calibration methods. The most up-to-date calibration technique, known as the “wedge method,” calibrates mainly one of the two constants and, if the crosstalk effect is properly analyzed, is primarily applicable to a sharp tip. In contrast, the D-LFC can calibrate both constants simultaneously for AFM tips or beads with any radius of curvature. These capabilities can extend the applicability of AFM lateral force measurement to studies of anisotropic multiscale friction processes and biomechanical behavior of cells and molecules under combined loading. Details of the D-LFC method as well as a comparison with the wedge method are provided in this article.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Calibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
An improved wedge calibration method for lateral force in atomic force microscopy
Varenberg, M., Etsion, I., & Halperin, G. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584082 · Cited by 427
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Variation of the Interfacial Shear Strength and Adhesion of a Nanometer-Sized Contact
Carpick, R. W., Agraït, N., Ogletree, D. F., & Salmeron, M. (1996) · Langmuir · doi:10.1021/la9509007 · Cited by 301
Diamagnetic levitation: Flying frogs and floating magnets (invited)
Simon, M. D., & Geim, A. K. (2000) · Journal of Applied Physics · doi:10.1063/1.372654 · Cited by 281
A Technique for Measuring the Force between a Colloidal Particle in Water and a Bubble
Butt, H.-J. (1994) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1994.1277 · Cited by 260
The Colloidal Probe Technique and its Application to Adhesion Force Measurements
Kappl, M., & Butt, H.-J. (2002) · Particle & Particle Systems Characterization · doi:10.1002/1521-4117(200207)19:3<129::aid-ppsc129>3.0.co;2-g · Cited by 256
Cited by
Frictional Characteristics of Atomically Thin Sheets
Lee, C., Li, Q., Kalb, W., Liu, X.-Z., Berger, H., Carpick, R. W., & Hone, J. (2010) · Science · doi:10.1126/science.1184167 · Cited by 1,811
Self-citationRobust microscale superlubricity in graphite/hexagonal boron nitride layered heterojunctions
Song, Y., Mandelli, D., Hod, O., Urbakh, M., Ma, M., & Zheng, Q. (2018) · Nature Materials · doi:10.1038/s41563-018-0144-z · Cited by 494
Carbon nanotube bundles with tensile strength over 80 GPa
Bai, Y., Zhang, R., Ye, X., Zhu, Z., Xie, H., Shen, B., Cai, D., Liu, B., Zhang, C., Jia, Z., et al. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0141-z · Cited by 449
Measurement of the cleavage energy of graphite
Wang, W., Dai, S., Li, X., Yang, J., Srolovitz, D. J., & Zheng, Q. (2015) · Nature Communications · doi:10.1038/ncomms8853 · Cited by 368
Robust microscale superlubricity under high contact pressure enabled by graphene-coated microsphere
Liu, S.-W., Wang, H.-P., Xu, Q., Ma, T.-B., Yu, G., Zhang, C., Geng, D., Yu, Z., Zhang, S., Wang, W., et al. (2017) · Nature Communications · doi:10.1038/ncomms14029 · Cited by 362
Frictional ageing from interfacial bonding and the origins of rate and state friction
Li, Q., Tullis, T. E., Goldsby, D., & Carpick, R. W. (2011) · Nature · doi:10.1038/nature10589 · Cited by 311
Self-citationLi, Q., Dong, Y., Perez, D., Martini, A., & Carpick, R. W. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.126101 · Cited by 218
Self-citationFluorination of Graphene Enhances Friction Due to Increased Corrugation
Li, Q., Liu, X.-Z., Kim, S.-P., Shenoy, V. B., Sheehan, P. E., Robinson, J. T., & Carpick, R. W. (2014) · Nano Letters · doi:10.1021/nl502147t · Cited by 174
Self-citationRobust ultra-low-friction state of graphene via moiré superlattice confinement
Zheng, X., Gao, L., Yao, Q., Li, Q., Zhang, M., Xie, X., Qiao, S., Wang, G., Ma, T., Di, Z., et al. (2016) · Nature Communications · doi:10.1038/ncomms13204 · Cited by 156
“The normal and lateral force were calibrated using the ramp mode 35 and the diamagnetic levitation spring system 36 .”
Self-citationSuperlubricity of Graphite Induced by Multiple Transferred Graphene Nanoflakes
Li, J., Gao, T., & Luo, J. (2018) · Advanced Science · doi:10.1002/advs.201700616 · Cited by 142
Superlubricity of Graphite Sliding against Graphene Nanoflake under Ultrahigh Contact Pressure
Li, J., Li, J., & Luo, J. (2018) · Advanced Science · doi:10.1002/advs.201800810 · Cited by 133
Deng, Z., Klimov, N. N., Solares, S. D., Li, T., Xu, H., & Cannara, R. J. (2013) · Langmuir · doi:10.1021/la304079a · Cited by 129
Microscale Schottky superlubric generator with high direct-current density and ultralong life
Huang, X., Xiang, X., Nie, J., Peng, D., Yang, F., Wu, Z., Jiang, H., Xu, Z., & Zheng, Q. (2021) · Nature Communications · doi:10.1038/s41467-021-22371-1 · Cited by 140
Scalable Synthesis of 2D Si Nanosheets
Lang, J., Ding, B., Zhang, S., Su, H., Ge, B., Qi, L., Gao, H., Li, X., Li, Q., & Wu, H. (2017) · Advanced Materials · doi:10.1002/adma.201701777 · Cited by 112
Self-citationQi, Y., Liu, J., Zhang, J., Dong, Y., & Li, Q. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b12916 · Cited by 99
Self-citationOrigin of Friction in Superlubric Graphite Contacts
Qu, C., Wang, K., Wang, J., Gongyang, Y., Carpick, R. W., Urbakh, M., & Zheng, Q. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.126102 · Cited by 98
Force calibration in lateral force microscopy: a review of the experimental methods
Munz, M. (2010) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/43/6/063001 · Cited by 112
Normal and Lateral Force Calibration Techniques for AFM Cantilevers
Palacio, M. L. B., & Bhushan, B. (2010) · Critical reviews in solid state and materials sciences/CRC critical reviews in solid state and materials sciences · doi:10.1080/10408430903546691 · Cited by 119
“59 copyright 2006: American Institute of Physics).”
BackgroundEasy and direct method for calibrating atomic force microscopy lateral force measurements
Liu, W., Bonin, K., & Guthold, M. (2007) · Review of Scientific Instruments · doi:10.1063/1.2745733 · Cited by 112
Pelrine, R., Wong-Foy, A., McCoy, B., Holeman, D., Mahoney, R., Myers, G., Herson, J. A., & Low, T. (2012) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2012.6225089 · Cited by 89
Superlubricity between Graphite Layers in Ultrahigh Vacuum
Liu, Y., Wang, K., Xu, Q., Zhang, J., Hu, Y., Ma, T., Zheng, Q., & Luo, J. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c05422 · Cited by 86
Observation of normal-force-independent superlubricity in mesoscopic graphite contacts
Vu, C. C., Zhang, S., Urbakh, M., Li, Q., He, Q., & Zheng, Q. (2016) · Physical review. B./Physical review. B · doi:10.1103/physrevb.94.081405 · Cited by 84
Self-citationQi, Y., Liu, J., Dong, Y., Feng, X., & Li, Q. (2018) · Carbon · doi:10.1016/j.carbon.2018.06.029 · Cited by 82
Self-citationOptical Motion Control of Maglev Graphite
Kobayashi, M., & Abe, J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja310365k · Cited by 76
Nanoscale Friction Behavior of Transition-Metal Dichalcogenides: Role of the Chalcogenide
Vazirisereshk, M. R., Hasz, K., Zhao, M., Johnson, A. T. C., Carpick, R. W., & Martini, A. (2020) · ACS Nano · doi:10.1021/acsnano.0c07558 · Cited by 77
Load and Time Dependence of Interfacial Chemical Bond-Induced Friction at the Nanoscale
Tian, K., Gosvami, N. N., Goldsby, D. L., Liu, Y., Szlufarska, I., & Carpick, R. W. (2017) · Physical Review Letters · doi:10.1103/physrevlett.118.076103 · Cited by 74
Peng, D., Wang, J., Jiang, H., Zhao, S., Wu, Z., Tian, K., Ma, M. D., & Zheng, Q. (2021) · National Science Review · doi:10.1093/nsr/nwab109 · Cited by 69
“The normal force and lateral force applied by the AFMtipwere calibratedbySader’smethod [54] and a diamagnetic calibrator [55] respectively (Supplementary Section 10).”
MethodLocal Nanoscale Heating Modulates Single-Asperity Friction
Greiner, C., Felts, J. R., Dai, Z., King, W. P., & Carpick, R. W. (2010) · Nano Letters · doi:10.1021/nl102809k · Cited by 63
Greiner, C., Felts, J. R., Dai, Z., King, W. P., & Carpick, R. W. (2012) · ACS Nano · doi:10.1021/nn300869w · Cited by 63
Structural superlubricity in graphite flakes assembled under ambient conditions
He, D. L., Ma, M. D., Song, Y., He, Q., & Zheng, Q. (2018) · Nanoscale · doi:10.1039/c7nr09628c · Cited by 62
Robust microscale structural superlubricity between graphite and nanostructured surface
Huang, X., Li, T., Wang, J., Xia, K., Tan, Z., Peng, D., Xiang, X., Liu, B., Ma, M. D., & Zheng, Q. (2023) · Nature Communications · doi:10.1038/s41467-023-38680-6 · Cited by 68
“The in situ calibration of the AFM tip was performed using the Sader method 27,28 for measuring normal direction forces and the diamagnetic levitation spring system 29 for measuring lateral direction forces.”
Mechanics of Crystalline Nanowires: An Experimental Perspective
Zhu, Y. (2016) · Applied Mechanics Reviews · doi:10.1115/1.4035511 · Cited by 63
Bennewitz, R. (2005) · Materials Today · doi:10.1016/s1369-7021(05)00845-x · Cited by 60
Wang, K., Zhang, J., Ma, T., Liu, Y., Song, A., Chen, X., Hu, Y., Carpick, R. W., & Luo, J. (2020) · Small · doi:10.1002/smll.202005607 · Cited by 57
The Origin of Moiré‐Level Stick‐Slip Behavior on Graphene/h‐BN Heterostructures
Huang, K., Qin, H., Zhang, S., Li, Q., Ouyang, W., & Liu, Y. (2022) · Advanced Functional Materials · doi:10.1002/adfm.202204209 · Cited by 60
Self-citationCharacterization of a Microscale Superlubric Graphite Interface
Wang, K., Qu, C., Wang, J., Quan, B., & Zheng, Q. (2020) · Physical Review Letters · doi:10.1103/physrevlett.125.026101 · Cited by 58
Micromechanics of friction: effects of nanometre-scale roughness
Li, Q., & Kim, K. (2008) · Proceedings of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rspa.2007.0364 · Cited by 64
“The lateral force constant was calibrated with the newly developed diamagnetic lateral force calibrator (Li et al. 2006).”
MethodSelf-citationŞahin, Ö. (2007) · Review of Scientific Instruments · doi:10.1063/1.2801009 · Cited by 59
Cross-talk correction in atomic force microscopy
Hoffmann, Á., Jungk, T., & Soergel, E. (2007) · Review of Scientific Instruments · doi:10.1063/1.2424448 · Cited by 50
Shi, R., Gao, L., Lu, H., Li, Q., Ma, T., Guo, H., Du, S., Feng, X., Zhang, S., Yanmin, L., et al. (2017) · 2D Materials · doi:10.1088/2053-1583/aa6da2 · Cited by 50
Self-citationMicroscale superlubricity of graphite under various twist angles
Wang, W. C., Shen, J., & He, Q. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.99.054103 · Cited by 47
Micromachined Graphite Rotor Based on Diamagnetic Levitation
Su, Y., Xiao, Z., Ye, Z., & Takahata, K. (2015) · IEEE Electron Device Letters · doi:10.1109/led.2015.2399493 · Cited by 45
“Diamagnetic levitation has been used for low-loss bearings [4]–[7], biomedical application [8], and atomic-force microscope calibration [9].”
BackgroundUnderstanding Interlayer Contact Conductance in Twisted Bilayer Graphene
Yu, Z., Song, A., Sun, L., Li, Y., Gao, L., Peng, H., Ma, T., Liu, Z., & Luo, J. (2019) · Small · doi:10.1002/smll.201902844 · Cited by 40
Variable-capacitance micromotor with levitated diamagnetic rotor
Liu, W., Chen, W., Zhang, W.-P., Huang, X., & Zhang, Z.-R. (2008) · Electronics Letters · doi:10.1049/el:20080528 · Cited by 39
Graphene levitation and orientation control using a magnetic field
Niu, C., Lin, F., Wang, Z. M., Bao, J., & Hu, J. (2018) · Journal of Applied Physics · doi:10.1063/1.5005539 · Cited by 41
Mechanical responses of boron-doped monolayer graphene
Dai, Z., Wang, G., Zheng, Z., Wang, Y., Zhang, S., Qi, X., Tan, P., Liu, L., Xu, Z., Li, Q., et al. (2019) · Carbon · doi:10.1016/j.carbon.2019.03.014 · Cited by 38
“Asylum Research (AR) Cypher was employed to perform friction and topography measurements in ambient conditions [31].”
MethodSelf-citationRunning-in behavior of a H-DLC/Al2O3 pair at the nanoscale
Shi, P., Sun, J., Liu, Y., Zhang, B., Zhang, J., Chen, L., & Qian, L. (2020) · Friction · doi:10.1007/s40544-020-0429-5 · Cited by 43
Comparison of friction and wear of articular cartilage on different length scales
Kienle, S., Boettcher, K., Wiegleb, L., Urban, J., Burgkart, R., Lieleg, O., & Hugel, T. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.07.027 · Cited by 38
Xie, H., Vitard, J., Haliyo, S. D., Régnier, S., & Boukallel, M. (2008) · Review of Scientific Instruments · doi:10.1063/1.2894209 · Cited by 38
Boundary Slip of Oil Molecules at MoS2 Homojunctions Governing Superlubricity
Li, J., Li, J., Yi, S., & Wang, K. (2022) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c00693 · Cited by 34
Microscale superlubricity at multiple gold–graphite heterointerfaces under ambient conditions
Li, J., Li, J., Chen, X., Liu, Y., & Luo, J. (2020) · Carbon · doi:10.1016/j.carbon.2020.01.070 · Cited by 33
Ma, M. D., Sokolov, I. M., Wang, W., Filippov, A. E., Zheng, Q., & Urbakh, M. (2015) · Physical Review X · doi:10.1103/physrevx.5.031020 · Cited by 34
AFM lateral force calibration for an integrated probe using a calibration grating
Wang, H., & Gee, M. L. (2013) · Ultramicroscopy · doi:10.1016/j.ultramic.2013.10.012 · Cited by 35
“Over the last 15 years, a variety of methods for calibrating lateral forces in AFM have been demonstrated [12, 14-34].”
MethodGraphite superlubricity enabled by triboinduced nanocontacts
Buzio, R., Gerbi, A., Bernini, C., Repetto, L., & Vanossi, A. (2021) · Carbon · doi:10.1016/j.carbon.2021.08.071 · Cited by 31
“force calibration factor , required to estimate the lateral force , was determined by means of a diamagnetic levitation spring system [35].”
MethodFriction hysteretic behavior of supported atomically thin nanofilms
Xu, C., Ye, Z., & Egberts, P. (2023) · npj 2D Materials and Applications · doi:10.1038/s41699-022-00363-z · Cited by 34
Chung, K., Pratt, J. R., & Reitsma, M. G. (2009) · Langmuir · doi:10.1021/la902488r · Cited by 33
Structural superlubricity with a contaminant-rich interface
Wang, K., He, Y., Cao, W., Wang, J., Qu, C., Chai, M., Liu, Y., Zheng, Q., & Ma, M. D. (2022) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2022.105063 · Cited by 30
Evaluation of Eddy-Current Effects on Diamagnetic Bearings for Microsystems
Chen, J., Zhou, J., Meng, G., & Zhang, W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2011346 · Cited by 29
“Such principle has been applied to the handling of diamagnetic particles and cells for laboratory-on-chip systems [9], [10], lateral-force calibration of atomic force microscopes [11], bearing solution of electrostatic glass motors for precise positioning [12], micro–nanoforce sensors [13], and accelerometers [14].”
BackgroundLateral force microscope calibration using a modified atomic force microscope cantilever
Reitsma, M. G. (2007) · Review of Scientific Instruments · doi:10.1063/1.2789653 · Cited by 29
An atomic-scale approach for biodiesel boundary lubricity characterisation
Chong, W. W. F., & Ng, J.-H. (2016) · International Biodeterioration & Biodegradation · doi:10.1016/j.ibiod.2016.03.029 · Cited by 27
A bi-stable horizontal diamagnetic levitation based low frequency vibration energy harvester
Palagummi, S., & Yuan, F. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.07.001 · Cited by 26
Khare, H. S., & Burris, D. L. (2013) · Review of Scientific Instruments · doi:10.1063/1.4804163 · Cited by 26
Diamagnetic bearings for MEMS: Performance and stability analysis
Chen, J., Zhou, J., & Meng, G. (2008) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2008.06.008 · Cited by 25
Fabrication of a graphene layer probe to measure force interactions in layered heterojunctions
Li, J., Li, J., Jiang, L., & Luo, J. (2020) · Nanoscale · doi:10.1039/c9nr09528d · Cited by 23
Lu, H., Goldman, J. L., Ding, F., Sun, Y., Pulikkathara, M. X., Khabashesku, V. N., Yakobson, B. I., & Lou, J. (2008) · Carbon · doi:10.1016/j.carbon.2008.05.010 · Cited by 23
“[19] Li Q, Rydberg A, Kim KS.”
MethodOptical power meter using radiation pressure measurement
Pinot, P., & Silvestri, Z. (2018) · Measurement · doi:10.1016/j.measurement.2018.07.087 · Cited by 22
“There are also other possible applications of PyC for measuring weak contact forces [27,28].”
BackgroundImpacts of the substrate stiffness on the anti-wear performance of graphene
Yao, Q., Qi, Y., Zhang, J., Zhang, S., Zhao, P., Wang, H., Feng, X., & Li, Q. (2019) · AIP Advances · doi:10.1063/1.5095055 · Cited by 22
Self-citationMetal Nanoparticle Harvesting by Continuous Rotating Electrodeposition and Separation
Huang, Y., Yang, C., Lang, J., Zhang, S., Feng, S., Schäfer, L., Carney, T. J., Mu, J., Lin, S., Zhou, Y., et al. (2020) · Matter · doi:10.1016/j.matt.2020.08.019 · Cited by 21
Self-citationPasquale, G. D., Iamoni, S., & Somà, A. (2013) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2012.12.018 · Cited by 21
“Li et al. [24] efficiently applied a magnetic levitated suspension system to an atomic force microscope for the calibration of the lateral force.”
A calibration method for lateral forces for use with colloidal probe force microscopy cantilevers
Quintanilla, M. A. S., & Goddard, D. T. (2008) · Review of Scientific Instruments · doi:10.1063/1.2836327 · Cited by 21
Hu, H., Wang, J., Tian, K., Zheng, Q., & Ma, M. D. (2024) · Nature Communications · doi:10.1038/s41467-024-55069-1 · Cited by 24
“The electric signal corresponding to the torsional deformation of the cantilever is recorded, and converted to the lateral force by a constant calibration factor which is obtained by the diamagnetic lateral force calibration method 41 .”
Yu, K., Peng, Y., Lang, H., Ding, S., & Huang, Y. T. (2021) · Carbon · doi:10.1016/j.carbon.2021.12.041 · Cited by 18
Optical lever calibration in atomic force microscope with a mechanical lever
Xie, H., Vitard, J., Haliyo, S. D., & Régnier, S. (2008) · Review of Scientific Instruments · doi:10.1063/1.2976108 · Cited by 19
Nanoscale friction as a function of activation energies
Chong, W. W. F., & Rahnejat, H. (2015) · Surface Topography Metrology and Properties · doi:10.1088/2051-672x/3/4/044002 · Cited by 18
Multi-agent systems using diamagnetic micro manipulation — From floating swarms to mobile sensors
Pelrine, R., Hsu, A. L., Cowan, C. K., & Wong-Foy, A. (2017) · International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS) · doi:10.1109/marss.2017.8001930 · Cited by 18
“Diamagnetic bearings have these same properties, and indeed, much of the early work in diamagnetic levitation focused on mechanical sensor applications [15, 16, 17].”
BackgroundOrtuso, R. D., & Sugihara, K. (2018) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.8b03583 · Cited by 18
Li, Q., Bi, S., Bu, J., Tang, C., Ouyang, Z., Jiang, C., & Song, J. (2019) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.9b02080 · Cited by 17
Self-citationCorrected direct force balance method for atomic force microscopy lateral force calibration
Asay, D. B., Hsiao, E., & Kim, S. H. (2009) · Review of Scientific Instruments · doi:10.1063/1.3142243 · Cited by 17
Cross-talk compensation in atomic force microscopy
Onal, C. D., Sümer, B., & Sitti, M. (2008) · Review of Scientific Instruments · doi:10.1063/1.3002483 · Cited by 17
Hamdan, S. H., Lee, C. T., Lee, M. B., Chong, W. W. F., Chong, C. T., & Sanip, S. M. (2020) · Friction · doi:10.1007/s40544-020-0428-4 · Cited by 16
Magnetic levitation and its application for low frequency vibration energy harvesting
Palagummi, S., & Yuan, F. (2016) · Elsevier eBooks · doi:10.1016/b978-0-08-100148-6.00008-1 · Cited by 19
Ye, X., Zhiguo, C., Fang, H., & Li, X. (2017) · Sensors · doi:10.3390/s17081800 · Cited by 16
“Above micro force sensors are calibrated before tests by electronic speckle pattern interferometry [58] and magnetic levitation vibrator calibration system [68,70].”
MethodDesign of Magnetic Force Field for Trajectory Control of Levitated Diamagnetic Graphite
Kang, S.-M., Kim, J.-H., Pyo, J., Cho, J. H., & Kim, T. (2018) · International Journal of Precision Engineering and Manufacturing-Green Technology · doi:10.1007/s40684-018-0036-3 · Cited by 17
Nanoscale frictional characteristics of graphene nanoribbons
Zhang, J., Lü, W., Tour, J. M., & Lou, J. (2012) · Applied Physics Letters · doi:10.1063/1.4752724 · Cited by 18
Effects of surface compliance and relaxation on the frictional properties of lamellar materials
Smolyanitsky, A., Zhu, S., Deng, Z., Li, T., & Cannara, R. J. (2014) · RSC Advances · doi:10.1039/c4ra03810j · Cited by 16
“4 [14] and a diamagnetic lateral force calibrator [15] were used to calibrate normal and lateral forces, respectively.”
New laser power sensor using diamagnetic levitation
Pinot, P., & Silvestri, Z. (2017) · Review of Scientific Instruments · doi:10.1063/1.4997961 · Cited by 15
Vibration-induced nanoscale friction modulation on piezoelectric materials
Cao, J., & Li, Q. (2022) · Friction · doi:10.1007/s40544-021-0552-y · Cited by 15
“The lateral force was calibrated using a diamagnetic levitation spring system [33].”
MethodSelf-citationYu, K., Xu, P., Peng, Y., Huang, Y. T., Lang, H., & Ding, S. (2022) · Materials Today Advances · doi:10.1016/j.mtadv.2023.100380 · Cited by 14
Wang, Y., Wang, J., Wu, T., Chen, W., Peng, D., Wu, Z., Ma, M. D., & Zheng, Q. (2024) · National Science Review · doi:10.1093/nsr/nwae019 · Cited by 19
“For each friction measurement detected by an AFM tip, the force was calibrated in situ just after the friction measurement, using the Sader method [32 ] for the normal direction and the diamagnetic lateral force calibration method [33 ] for the lateral direction.”
MethodTorsional force microscopy of van der Waals moirés and atomic lattices
Pendharkar, M., Tran, S. J., Zaborski, G., Finney, J., Sharpe, A. L., Kamat, R., Kalantre, S. S., Hocking, M. B., Bittner, N. J., Watanabe, K., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2314083121 · Cited by 27
Electrostatic in-plane structural superlubric actuator
Huang, X., Xiang, X., Li, C., Nie, J., Shao, Y., Xu, Z., & Zheng, Q. (2025) · Nature Communications · doi:10.1038/s41467-024-55078-0 · Cited by 19
“The signal was then converted to the friction by a calibration factor obtained from a diamagnetic lateral force calibration experiment 44 , and to the normal force by another calibration factor derivated from the Sader method 45,46 .”
Sha, T.-D., Pang, H., Fang, L., Liu, H., Chen, X., Liu, D., & Luo, J. (2020) · Nanotechnology · doi:10.1088/1361-6528/ab70cd · Cited by 13
“The normal spring constant of the tip was determined by the frequency method [15], and the lateral detector sensitivity of the tip was obtained using a silicon calibration grating [16] (TGX1, NT-MDT).”
MethodBifurcation of nanoscale thermolubric friction behavior for sliding on MoS2
Hasz, K., Vazirisereshk, M. R., Martini, A., & Carpick, R. W. (2021) · Physical Review Materials · doi:10.1103/physrevmaterials.5.083607 · Cited by 14
Intercalated water-induced hysteretic friction behavior of graphene, h-BN, and MoS 2
Xu, C., Ye, Z., & Egberts, P. (2023) · Applied Surface Science · doi:10.1016/j.apsusc.2023.157442 · Cited by 15
Bennewitz, R. (2014) · Nanoscience and technology · doi:10.1007/978-3-319-10560-4_1 · Cited by 13
Ultralow‐Friction at Cryogenic Temperature Induced by Hydrogen Correlated Quantum Effect
Chen, W., Wang, K., Miao, X., Zhang, J., Song, A., Chen, X., Luo, J., & Ma, T. (2024) · Small · doi:10.1002/smll.202400083 · Cited by 13
Diamagnetically levitating resonant weighing scale
Chen, X., Kothari, N., Keşkekler, A., Steeneken, P. G., & Alijani, F. (2021) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2021.112842 · Cited by 12
Diamagnetic levitation and thermal gradient driven motion of graphite
Fujimoto, M., & Koshino, M. (2019) · Physical review. B./Physical review. B · doi:10.1103/physrevb.100.045405 · Cited by 14
Ma, X., Wang, W., Xie, G., Guo, D., & Wen, S. (2020) · Micro & Nano Letters · doi:10.1049/mnl.2020.0383 · Cited by 12
Hairy-Layer Friction Reduction Mechanism in the Honeybee Abdomen
Wang, M., Chen, W., Zhao, J., Li, Y., & Yan, S. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c05500 · Cited by 15
Metadata
- Authors
- Li, Q., Kim, K.-S., & Rydberg, A.
- Affiliations
- Brown University (US)
- ORCID
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-06-01
- Volume
- 77
- Issue
- 6
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2029314957
- Cited by
- 208
- References
- 18
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 15 · 2023: 12 · 2022: 10 · 2021: 10 · 2020: 20 · 2019: 10 · 2018: 17 · 2017: 10 · 2016: 9 · 2015: 9 · 2014: 4 · 2013: 4 · 2012: 13
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 13 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 13 d)
- Locations
- Review of Scientific Instruments (publishedVersion, cc-by)
- Funders
- Rice University
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
- Keywords
- atomic force microscopy, diamagnetic levitation, wedge method, friction measurement, Nd-Fe-B permanent magnets, pyrolytic graphite
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.