Stiff subcircuit islands of diamondlike carbon for stretchable electronics
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Stretchable electronics on elastomeric substrates requires fragile and brittle device materials to be placed on stiff, mechanical distinct subcircuit islands. We deposited a diamondlike carbon (DLC) film at room temperature on a silicone substrate by pulsed laser ablation, and patterned the film into an array of 200×200μm2 islands. When the substrate was uniaxially stretched to a strain of 25%, the islands remained adherent to the substrate and only deformed by ∼5%, while the exposed substrate stretched by more than 30%. A row of 11 DLC islands interconnected with gold stretchable metallization maintained end-to-end electrical conduction during a mechanical cycle to 20% tensile strain. This demonstration of electrically interconnected stiff islands on silicone illustrates two important steps toward fully integrated, elastically stretchable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Cited by
Soft Microfluidic Assemblies of Sensors, Circuits, and Radios for the Skin
Xu, S., Zhang, Y., Jia, L., Mathewson, K. E., Jang, K.-I., Kim, J., Fu, H., Huang, X., Chava, P., Wang, R., et al. (2014) · Science · doi:10.1126/science.1250169 · Cited by 1,199
Finite deformation mechanics in buckled thin films on compliant supports
Jiang, H., Khang, D.-Y., Song, J., Sun, Y., Huang, Y., & Rogers, J. A. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702927104 · Cited by 721
Materials for stretchable electronics
Wagner, S., & Bauer, S. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.37 · Cited by 449
Self-citationDesign of metal interconnects for stretchable electronic circuits
Gonzalez, M., Axisa, F., Bulcke, M. V., Brosteaux, D., Vandevelde, B., & Vanfleteren, J. (2008) · Microelectronics Reliability · doi:10.1016/j.microrel.2008.03.025 · Cited by 405
“Common metal conductors used in the electronic industry have very limited elastic ranges; therefore a metallization design is crucial to allow stretchability of the conductors going up to 100%.”
BackgroundHarris, K. D., Elias, A. L., & Chung, H.-J. (2016) · Journal of Materials Science · doi:10.1007/s10853-015-9643-3 · Cited by 403
Strain-insensitive intrinsically stretchable transistors and circuits
Wang, W., Wang, S., Rastak, R., Ochiai, Y., Niu, S., Jiang, Y., Arunachala, P. K., Zheng, Y., Xu, J., Matsuhisa, N., et al. (2021) · Nature Electronics · doi:10.1038/s41928-020-00525-1 · Cited by 360
Kim, R.-H., Bae, M.-H., Kim, D. G., Cheng, H., Kim, B. H., Kim, D.-H., Li, M., Wu, J., Du, F., Kim, H.-S., et al. (2011) · Nano Letters · doi:10.1021/nl202000u · Cited by 334
Stretchable transistors and functional circuits for human-integrated electronics
Dai, Y., Hu, H., Wang, M., Xu, J., & Wang, S. (2021) · Nature Electronics · doi:10.1038/s41928-020-00513-5 · Cited by 315
Stretchable electronics based on Ag-PDMS composites
Larmagnac, A., Eggenberger, S., Janossy, H., & Vörös, J. (2014) · Scientific Reports · doi:10.1038/srep07254 · Cited by 296
Buckling of a stiff thin film on a compliant substrate in large deformation
Song, J., Jiang, H., Liu, Z. J., Khang, D. Y., Huang, Y., Rogers, J. A., Lu, C., & Koh, C. G. (2008) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2008.01.023 · Cited by 282
Mechanics of ultra-stretchable self-similar serpentine interconnects
Zhang, Y., Fu, H., Su, Y., Xu, S., Cheng, H., Fan, J. A., Hwang, K.-C., Rogers, J. A., & Huang, Y. (2013) · Acta Materialia · doi:10.1016/j.actamat.2013.09.020 · Cited by 230
Flexible Organic Transistors for Biosensing: Devices and Applications
Song, J., Liu, H., Zhao, Z., Lin, P., & Yan, F. (2024) · Advanced Materials · doi:10.1002/adma.202300034 · Cited by 220
Mechanics of stretchable electronics and soft machines
Suo, Z. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.32 · Cited by 216
Self-citationArrays of Ultracompliant Electrochemical Dry Gel Cells for Stretchable Electronics
Kaltenbrunner, M., Kettlgruber, G., Siket, C., Schwödiauer, R., & Bauer, S. (2010) · Advanced Materials · doi:10.1002/adma.200904068 · Cited by 165
Silicone substrate with in situ strain relief for stretchable thin-film transistors
Graz, I. M., Cotton, D. P. J., Robinson, A., & Lacour, S. P. (2011) · Applied Physics Letters · doi:10.1063/1.3570661 · Cited by 111
Self-citationRecent advances in materials and flexible electronics for peripheral nerve interfaces
Bettinger, C. J. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0007-6 · Cited by 77
Metadata
- Authors
- Lacour, S. P., Wagner, S., Narayan, R. J., Li, T., & Suo, Z.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2006-07-01
- Volume
- 100
- Issue
- 1
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2099803111
- Cited by
- 118
- References
- 1
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.