CoChat

Recent advances in materials and flexible electronics for peripheral nerve interfaces

Open access
Bettinger, Christopher J. · 2018 · Bioelectronic Medicine

The DOI matches its Crossref record; 77 of the 79 references it cites were found in a registry or an index.

Abstract

Peripheral nerve interfaces are a central technology in advancing bioelectronic medicines because these medical devices can record and modulate the activity of nerves that innervate visceral organs. Peripheral nerve interfaces that use electrical signals for recording or stimulation have advanced our collective understanding of the peripheral nervous system. Furthermore, devices such as cuff electrodes and multielectrode arrays of various form factors have been implanted in the peripheral nervous system of humans in several therapeutic contexts. Substantive advances have been made using devices composed of off-the-shelf commodity materials. However, there is also a demand for improved device performance including extended chronic reliability, enhanced biocompatibility, and increased bandwidth for recording and stimulation. These aspirational goals manifest as much needed improvements in device performance including: increasing mechanical compliance (reducing Young's modulus and increasing extensibility); improving the barrier properties of encapsulation materials; reducing impedance and increasing the charge injection capacity of electrode materials; and increasing the spatial resolution of multielectrode arrays. These proposed improvements require new materials and novel microfabrication strategies. This mini-review highlights selected recent advances in flexible electronics for peripheral nerve interfaces. The foci of this mini-review include novel materials for flexible and stretchable substrates, non-conventional microfabrication techniques, strategies for improved device packaging, and materials to improve signal transduction across the tissue-electrode interface. Taken together, this article highlights challenges and opportunities in materials science and processing to improve the performance of peripheral nerve interfaces and advance bioelectronic medicine.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s42234-018-0007-6

Cites

77 of 77 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig. 1 Peripheral nerve interfaces (PNI) consisting of both inserted probes and cuff electrodes damage the target tissue and alter the underlying physiology. Utah slant electrodes (left) inserted into feline sciatic nerves induces inflammation, glial scarring, and rearrangement of the fascicles as shown by histology. Retraction of nerve fibers (green) is shown in the transverse axis while rearrangement of the fibers is shown in the longitudinal axis. This figure is adapted from the following sources and used with permission: Grill et al. (copyright 2000 John Wiley & Sons) (Grill & Mortimer, 2000); Christensen et al. (copyright 2014, Springer) (Christensen et al., 2014)
Fig. 1 Peripheral nerve interfaces (PNI) consisting of both inserted probes and cuff electrodes damage the target tissue and alter the underlying physiology. Utah slant electrodes (left) inserted into feline sciatic nerves induces inflammation, glial scarring, and rearrangement of the fascicles as shown by histology. Retraction of nerve fibers (green) is shown in the transverse axis while rearrangement of the fibers is shown in the longitudinal axis. This figure is adapted from the following sources and used with permission: Grill et al. (copyright 2000 John Wiley & Sons) (Grill & Mortimer, 2000); Christensen et al. (copyright 2014, Springer) (Christensen et al., 2014)CC BY · PubMed Central
Fig. 2 There are several important dimensions to consider in the design of peripheral nerve interfaces (PNI) with improved performance. 1) The electrode density can be improved through advances in device fabrication and manufacturing. The resolution of recording can also be improved by new form factors and materials that anchor the device in close proximity to the target tissue. 2) Electrodes can be fabricated on dynamic and smart materials that adopt unique shapes, respond to stimuli, or manage the in vivo tissue response. 3) PNI can be fabricated on flexible and stretchable substrates to match the mechanical properties of the target tissue. Elastomeric substrates such as silicones can match the properties of tissues in the spinal cord. Substrate materials with increased compliance will be required to match the mechanical properties of nerves in the PNS with smaller diameters. This figure is adapted from the following sources and used with permission: Cutrone et al. (copyright 2015, Institute of Physics)(Cutrone et al., 2015); Minev et al. (copyright 2015, American Association for the Advancement of Science) (Minev et al., 2015)
Fig. 2 There are several important dimensions to consider in the design of peripheral nerve interfaces (PNI) with improved performance. 1) The electrode density can be improved through advances in device fabrication and manufacturing. The resolution of recording can also be improved by new form factors and materials that anchor the device in close proximity to the target tissue. 2) Electrodes can be fabricated on dynamic and smart materials that adopt unique shapes, respond to stimuli, or manage the in vivo tissue response. 3) PNI can be fabricated on flexible and stretchable substrates to match the mechanical properties of the target tissue. Elastomeric substrates such as silicones can match the properties of tissues in the spinal cord. Substrate materials with increased compliance will be required to match the mechanical properties of nerves in the PNS with smaller diameters. This figure is adapted from the following sources and used with permission: Cutrone et al. (copyright 2015, Institute of Physics)(Cutrone et al., 2015); Minev et al. (copyright 2015, American Association for the Advancement of Science) (Minev et al., 2015)CC BY · PubMed Central
Fig. 3 Modulus matching can guide the design of flexible and biointegrated electronic devices. The mechanical properties of various classes of materials used in microfabricated electronic devices (top) and organs in the human body (bottom) are plotted on a logarithmic spectrum of mechanical modulus. Materials traditionally used in microelectronic device fabrication (e.g. silicon, oxides, and metals) exhibit Young’s moduli that are orders of magnitude larger than the excitable tissues with which they are intended to interface including the peripheral nervous system. There are opportunities to engineer PNI with stretchable and ultracompliant electrode materials that can better match the mechanical properties of the target tissue
Fig. 3 Modulus matching can guide the design of flexible and biointegrated electronic devices. The mechanical properties of various classes of materials used in microfabricated electronic devices (top) and organs in the human body (bottom) are plotted on a logarithmic spectrum of mechanical modulus. Materials traditionally used in microelectronic device fabrication (e.g. silicon, oxides, and metals) exhibit Young’s moduli that are orders of magnitude larger than the excitable tissues with which they are intended to interface including the peripheral nervous system. There are opportunities to engineer PNI with stretchable and ultracompliant electrode materials that can better match the mechanical properties of the target tissueCC BY · PubMed Central
Fig. 4 Peripheral nerve interfaces (PNI) that use organic electrodes offer at least two prominent advantages compared to interfaces composed of traditional inorganic materials. Silicon-based substrates are depicted here as an example. First, organic electrodes obviate the formation of oxide layers, which facilitates charge transport thereby potentially reducing the size of the electrode and improving spatial resolution. Second, organic electrodes, such as those composed of conducting poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrene sulfonate) (PSS), can support both electronic and ionic transport. Organic electrodes therefore have the potential to transduce ionic signals emanating from neurons into electronic signals, which can be recorded by microelectronic devices (or vice versa). This figure is adapted from the following source and used with permission: Rivnay et al. (copyright 2014, American Chemical Society) (Rivnay et al., 2014)
Fig. 4 Peripheral nerve interfaces (PNI) that use organic electrodes offer at least two prominent advantages compared to interfaces composed of traditional inorganic materials. Silicon-based substrates are depicted here as an example. First, organic electrodes obviate the formation of oxide layers, which facilitates charge transport thereby potentially reducing the size of the electrode and improving spatial resolution. Second, organic electrodes, such as those composed of conducting poly(3,4-ethylenedioxythiophene) (PEDOT) doped with poly(styrene sulfonate) (PSS), can support both electronic and ionic transport. Organic electrodes therefore have the potential to transduce ionic signals emanating from neurons into electronic signals, which can be recorded by microelectronic devices (or vice versa). This figure is adapted from the following source and used with permission: Rivnay et al. (copyright 2014, American Chemical Society) (Rivnay et al., 2014)CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 77 references

Research works printed but not linked: 2

  1. Grill WM, Mortimer JT. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. J Biomed Mater Res. 2000;50:215–26. · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.0.co;2-a
  2. Xie X, et al. Long-term reliability of Al 2 O 3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation. J Neural Eng. 2014b;11:026016. · DOI · Paper page

Cited by

See all 85

Metadata

Authors
Bettinger, C. J.
Affiliations
Carnegie Mellon University (US)
Corresponding author
Bettinger, Christopher J.
Venue
Bioelectronic Medicine
Published
2018-05-23
Volume
4
Issue
1
Pages
6-6
ISSN
2332-8886 (ISSN-L)
OpenAlex
W2805175178
Cited by
77
References
79
Citations by year
2026: 6 · 2025: 10 · 2024: 7 · 2023: 10 · 2022: 14 · 2021: 13 · 2020: 8 · 2019: 9
FWCI
0.97
Type
journal article
Language
en
Open access
Licence
Locations
  • Bioelectronic Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Defense Advanced Research Projects Agency (D14AP00040)
  • Division of Materials Research (DMR1542196)
  • National Institutes of Health (R21NS095250)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
Keywords
peripheral nerve interfaces, flexible electronics, stretchable substrates, cuff electrodes, microelectrode arrays, biocompatibility, electrode-tissue interface, microfabrication, device packaging, encapsulation materials, electrode materials

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Recent advances in materials and flexible electronics for peripheral nerve interfaces. https://app.cochat.ai/papers/10.1186/s42234-018-0007-6
The paper
Bettinger, C. J. (2018). Recent advances in materials and flexible electronics for peripheral nerve interfaces. Bioelectronic Medicine. https://doi.org/10.1186/s42234-018-0007-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.