Recent advances in materials and flexible electronics for peripheral nerve interfaces
Open accessThe DOI matches its Crossref record; 77 of the 79 references it cites were found in a registry or an index.
Abstract
Peripheral nerve interfaces are a central technology in advancing bioelectronic medicines because these medical devices can record and modulate the activity of nerves that innervate visceral organs. Peripheral nerve interfaces that use electrical signals for recording or stimulation have advanced our collective understanding of the peripheral nervous system. Furthermore, devices such as cuff electrodes and multielectrode arrays of various form factors have been implanted in the peripheral nervous system of humans in several therapeutic contexts. Substantive advances have been made using devices composed of off-the-shelf commodity materials. However, there is also a demand for improved device performance including extended chronic reliability, enhanced biocompatibility, and increased bandwidth for recording and stimulation. These aspirational goals manifest as much needed improvements in device performance including: increasing mechanical compliance (reducing Young's modulus and increasing extensibility); improving the barrier properties of encapsulation materials; reducing impedance and increasing the charge injection capacity of electrode materials; and increasing the spatial resolution of multielectrode arrays. These proposed improvements require new materials and novel microfabrication strategies. This mini-review highlights selected recent advances in flexible electronics for peripheral nerve interfaces. The foci of this mini-review include novel materials for flexible and stretchable substrates, non-conventional microfabrication techniques, strategies for improved device packaging, and materials to improve signal transduction across the tissue-electrode interface. Taken together, this article highlights challenges and opportunities in materials science and processing to improve the performance of peripheral nerve interfaces and advance bioelectronic medicine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures




Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These implants are constructed from a library of materials that are readily absorbed into the body such as silk and polyurethanes for insulation and magnesium for electrical conductors.”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Bettinger 2018
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In recent years, profiting from the academic interest and deep exploration in neuroscience, flexible implantable stimulators with various mechanisms (electrical,[521–523] optogenetic,[524,525] ultrasonic,[526,527] magnetic[528]) are being developed as non-pharmacological treatment options.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [527]
The cited source says what the claim attributes to it.
In the citing paper
“They are designed to dissolve post-implantation after a period has elapsed removing the need for surgery to remove the implant.”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Bettinger 2018
The cited source says what the claim attributes to it.
In the citing paper
“For example, Hoffmann etal. state that there has yet be a standardised method for quality electrical encapsulation, though composite bilayers are offering a potential solution (Bettinger 2018; Hoffmann etal. 2006).”
From Peripheral nerve bionic interface: a review of electrodes (2019) · cites this paper as Bettinger 2018
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Dissolvable films of silk fibroin for ultrathin conformal bio-integrated electronics
Kim, D.-H., Viventi, J., Amsden, J. J., Xiao, J., Vigeland, L., Kim, Y.-S., Blanco, J. A., Panilaitis, B., Frechette, E. S., Contreras, D., et al. (2010) · Nature Materials · doi:10.1038/nmat2745 · Cited by 1,721
Embedded 3D Printing of Strain Sensors within Highly Stretchable Elastomers
Muth, J. T., Vogt, D. M., Truby, R. L., Mengüç, Y., Kolesky, D. B., Wood, R. J., & Lewis, J. A. (2014) · Advanced Materials · doi:10.1002/adma.201400334 · Cited by 1,611
Transfer printing by kinetic control of adhesion to an elastomeric stamp
Meitl, M. A., Zhu, Z.-T., Kumar, V., Lee, K. J., Feng, X., Huang, Y. Y., Adesida, I., Nuzzo, R. G., & Rogers, J. A. (2006) · Nature Materials · doi:10.1038/nmat1532 · Cited by 1,548
A tough biodegradable elastomer
Wang, Y., Ameer, G. A., Sheppard, B. J., & Langer, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0602-602 · Cited by 1,314
A Physically Transient Form of Silicon Electronics
Hwang, S.-W., Tao, H., Kim, D.-H., Cheng, H., Song, J.-K., Rill, E., Brenckle, M. A., Panilaitis, B., Won, S. M., Kim, Y.-S., et al. (2012) · Science · doi:10.1126/science.1226325 · Cited by 1,286
Calculation of interfacial tension in polymer systems
Wu, S. (1971) · Journal of Polymer Science Part C: Polymer Symposia · doi:10.1002/polc.5070340105 · Cited by 1,198
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
“Green” electronics: biodegradable and biocompatible materials and devices for sustainable future
Irimia-Vladu, M. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60235d · Cited by 1,044
3D Printing of Free Standing Liquid Metal Microstructures
Ladd, C., So, J., Muth, J., & Dickey, M. D. (2013) · Advanced Materials · doi:10.1002/adma.201301400 · Cited by 926
Research works printed but not linked: 2
- Grill WM, Mortimer JT. Neural and connective tissue response to long-term implantation of multiple contact nerve cuff electrodes. J Biomed Mater Res. 2000;50:215–26. · doi:10.1002/(sici)1097-4636(200005)50:2<215::aid-jbm17>3.0.co;2-a
- Xie X, et al. Long-term reliability of Al 2 O 3 and Parylene C bilayer encapsulated Utah electrode array based neural interfaces for chronic implantation. J Neural Eng. 2014b;11:026016. · DOI · Paper page
Cited by
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Stretchable electrochemical energy storage devices
Mackanic, D. G., Chang, T.-H., Huang, Z., Cui, Y., & Bao, Z. (2020) · Chemical Society Reviews · doi:10.1039/d0cs00035c · Cited by 335
Water-responsive supercontractile polymer films for bioelectronic interfaces
Yi, J., Zou, G., Huang, J., Ren, X., Tian, Q., Yu, Q., Wang, P., Yuan, Y., Tang, W., Wang, C., et al. (2023) · Nature · doi:10.1038/s41586-023-06732-y · Cited by 240
Bai, W., Shin, J. H., Fu, R., Kandela, I. K., Lu, D., Ni, X., Park, Y., Liu, Z., Hang, T., Wu, D., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0435-y · Cited by 149
Recent Progress in Materials Chemistry to Advance Flexible Bioelectronics in Medicine
Balakrishnan, G., Song, J., Mou, C., & Bettinger, C. J. (2021) · Advanced Materials · doi:10.1002/adma.202106787 · Cited by 136
Self-citation
Metadata
- Authors
- Bettinger, C. J.
- Affiliations
- Carnegie Mellon University (US)
- Corresponding author
- Bettinger, Christopher J.
- Venue
- Bioelectronic Medicine
- Published
- 2018-05-23
- Volume
- 4
- Issue
- 1
- Pages
- 6-6
- ISSN
- 2332-8886 (ISSN-L)
- PMC
- PMC7098226
- OpenAlex
- W2805175178
- Semantic Scholar
- 4a967a97c3653980298d16543c89ce0f531f8fef
- Cited by
- 77
- References
- 79
- Citations by year
- 2026: 6 · 2025: 10 · 2024: 7 · 2023: 10 · 2022: 14 · 2021: 13 · 2020: 8 · 2019: 9
- FWCI
- 0.97
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/4.0/ (tdm)
- creativecommons.org/licenses/by/4.0/ (vor)
- Locations
- Bioelectronic Medicine (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Defense Advanced Research Projects Agency (D14AP00040)
- Division of Materials Research (DMR1542196)
- National Institutes of Health (R21NS095250)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Keywords
- peripheral nerve interfaces, flexible electronics, stretchable substrates, cuff electrodes, microelectrode arrays, biocompatibility, electrode-tissue interface, microfabrication, device packaging, encapsulation materials, electrode materials
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent advances in materials and flexible electronics for peripheral nerve interfaces. https://app.cochat.ai/papers/10.1186/s42234-018-0007-6
- The paper
- Bettinger, C. J. (2018). Recent advances in materials and flexible electronics for peripheral nerve interfaces. Bioelectronic Medicine. https://doi.org/10.1186/s42234-018-0007-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.