CoChat

Carrier lifetime measurement in n− 4H-SiC epilayers

Klein, P. B. · 2008 · Journal of Applied Physics
Cited by 176

The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.

Abstract

The effects of measurement technique and measurement conditions (e.g., injection level, temperature) on measured carrier lifetimes in n− 4H-SiC epilayers are investigated both experimentally and through detailed carrier dynamics simulations to better understand differences between reported lifetimes. Three common, optically based techniques are compared: time resolved photoluminescence, transient free carrier absorption, and microwave photoconductivity decay. From the details of these measurement techniques it is shown from both theory and experiment that for the limits of high or low injection, these techniques can reflect very different lifetimes. The effect of measurement conditions on the carrier lifetime was approached by simulating the carrier dynamics assuming a dominant Z1/Z2 defect in order to calculate the evolution of the lifetimes and the carrier and defect charge state concentrations for arbitrary injection level or temperature, as a closed-form solution to this problem does not exist. The simulated behavior was found to be in reasonable agreement with experiment and the resulting values for the electron and hole capture cross sections for the 0/+ transition of Z1/Z2 were found to be σn2≈(2−4)×10−15 cm2 and σp2≈(1−2)×10−14 cm2, respectively. The simulations provide insight into the dominant processes controlling the lifetime and identify four distinct stages of decay. A simple expression for the ratio of high- to low-injection lifetimes is presented which compares well with experiment. The temperature dependence of the lifetime is found to be relatively weak below 500 K and thermally activated immediately above this temperature due to electron emission from the Z0 state. Electron emission from Z− and hole emission become important only at higher temperatures. Simulations with both Z1/Z2 and EH6/EH7 defects suggest the latter does not contribute significantly to the lifetime in as-grown epilayers, due primarily to a small capture cross section for holes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.2837105

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 16 references

Cited by

Metadata

Authors
Klein, P. B.
Venue
Journal of Applied Physics
Published
2008-02-01
Volume
103
Issue
3
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2029011367
Cited by
176
References
16
FWCI
10.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.