Carrier lifetime measurement in n− 4H-SiC epilayers
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The effects of measurement technique and measurement conditions (e.g., injection level, temperature) on measured carrier lifetimes in n− 4H-SiC epilayers are investigated both experimentally and through detailed carrier dynamics simulations to better understand differences between reported lifetimes. Three common, optically based techniques are compared: time resolved photoluminescence, transient free carrier absorption, and microwave photoconductivity decay. From the details of these measurement techniques it is shown from both theory and experiment that for the limits of high or low injection, these techniques can reflect very different lifetimes. The effect of measurement conditions on the carrier lifetime was approached by simulating the carrier dynamics assuming a dominant Z1/Z2 defect in order to calculate the evolution of the lifetimes and the carrier and defect charge state concentrations for arbitrary injection level or temperature, as a closed-form solution to this problem does not exist. The simulated behavior was found to be in reasonable agreement with experiment and the resulting values for the electron and hole capture cross sections for the 0/+ transition of Z1/Z2 were found to be σn2≈(2−4)×10−15 cm2 and σp2≈(1−2)×10−14 cm2, respectively. The simulations provide insight into the dominant processes controlling the lifetime and identify four distinct stages of decay. A simple expression for the ratio of high- to low-injection lifetimes is presented which compares well with experiment. The temperature dependence of the lifetime is found to be relatively weak below 500 K and thermally activated immediately above this temperature due to electron emission from the Z0 state. Electron emission from Z− and hole emission become important only at higher temperatures. Simulations with both Z1/Z2 and EH6/EH7 defects suggest the latter does not contribute significantly to the lifetime in as-grown epilayers, due primarily to a small capture cross section for holes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Semiconductor Material and Device Characterization
Schroder, D. K. (2005) · Wiley eBooks · doi:10.1002/0471749095 · Cited by 7,435
Statistics of the Recombinations of Holes and Electrons
Shockley, W., & Read, W. T. (1952) · Physical Review · doi:10.1103/physrev.87.835 · Cited by 6,589
Electron-Hole Recombination in Germanium
Hall, R. N. (1952) · Physical Review · doi:10.1103/physrev.87.387 · Cited by 2,776
(1995) · Choice Reviews Online · doi:10.5860/choice.32-5716 · Cited by 1,699
(1992) · Semiconductors and Semimetals · doi:10.1016/s0080-8784(08)62508-9 · Cited by 598
Sproul, A. B. (1994) · Journal of Applied Physics · doi:10.1063/1.357521 · Cited by 433
Deep Defect Centers in Silicon Carbide Monitored with Deep Level Transient Spectroscopy
Dalibor, T., Pensl, G., Matsunami, H., Kimoto, T., Choyke, W. J., Schöner, A., & Nordell, N. (1997) · physica status solidi (a) · doi:10.1002/1521-396x(199707)162:1<199::aid-pssa199>3.0.co;2-0 · Cited by 432
Lifetime-limiting defects in n− 4H-SiC epilayers
Klein, P. B., Shanabrook, B. V., Huh, S. W., Polyakov, A. Y., Skowronski, M., Sumakeris, J. J., & O’Loughlin, M. J. (2006) · Applied Physics Letters · doi:10.1063/1.2170144 · Cited by 222
Self-citationInvestigation of carrier lifetime in 4H-SiC epilayers and lifetime control by electron irradiation
Danno, K., Nakamura, D., & Kimoto, T. (2007) · Applied Physics Letters · doi:10.1063/1.2740580 · Cited by 221
Reduction of traps and improvement of carrier lifetime in 4H-SiC epilayers by ion implantation
Storasta, L., & Tsuchida, H. (2007) · Applied Physics Letters · doi:10.1063/1.2472530 · Cited by 199
Electrically active defects in n-type 4H–silicon carbide grown in a vertical hot-wall reactor
Zhang, J., Storasta, L., Bergman, J. P., Son, N. T., & Janzén, E. (2003) · Journal of Applied Physics · doi:10.1063/1.1543240 · Cited by 192
Investigation of deep levels in n-type 4H-SiC epilayers irradiated with low-energy electrons
Danno, K., & Kimoto, T. (2006) · Journal of Applied Physics · doi:10.1063/1.2401658 · Cited by 168
Negative-U centers in 4 H silicon carbide
Hemmingsson, C. G., Son, N. T., Ellison, A., Zhang, J., & Janzén, E. (1998) · Physical Review B · doi:10.1103/physrevb.58.r10119 · Cited by 166
Alfieri, G., Monakhov, E. V., Svensson, B. G., & Linnarsson, M. K. (2005) · Journal of Applied Physics · doi:10.1063/1.2009816 · Cited by 129
Transient Recombination of Excess Carriers in Semiconductors
Wertheim, G. K. (1958) · Physical Review · doi:10.1103/physrev.109.1086 · Cited by 129
The minority carrier lifetime of n-type 4H- and 6H-SiC epitaxial layers
Kordina, O., Bergman, J. P., Hallin, C., & Janzén, E. (1996) · Applied Physics Letters · doi:10.1063/1.117804 · Cited by 89
Cited by
Li, C., Luo, H., Li, C., Li, W., Yang, H., & He, X. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2890303 · Cited by 59
“The defect Z1/2 in 4H-SiC is a common intrinsic type of defect, which means it is stable and can be found in all the SiC power MOSFETs [28].”
Background
Metadata
- Authors
- Klein, P. B.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2008-02-01
- Volume
- 103
- Issue
- 3
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2029011367
- Cited by
- 176
- References
- 16
- FWCI
- 10.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.