Photoconductive response correction for detectors of terahertz radiation
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Photoconductive detectors are convenient devices for detecting pulsed terahertz radiation. We have optimized Fe+ ion-damaged InP materials for photoconductive detector signal to noise performance using dual-energy doses in the range from 2.5×1012 to 1.0×1016 cm−2. Ion implantation allowed the production of semiconducting materials with free-carrier lifetimes between 0.5 and 2.1 ps, which were measured by optical pump terahertz probe spectroscopy. The time resolved photoconductivity of the detector substrates was acquired as a function of time after excitation by 2 nJ pulses from a laser oscillator. These data, when combined with a deconvolution algorithm, provide an excellent spectral response correction to the raw photocurrent signal recorded by the photoconductive detectors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Picosecond photoconducting Hertzian dipoles
Auston, D. H., Cheung, K. P., & Smith, P. R. (1984) · Applied Physics Letters · doi:10.1063/1.95174 · Cited by 1,037
Ultrabroadband photoconductive detection: Comparison with free-space electro-optic sampling
Kono, S., Tani, M., & Sakai, K. (2001) · Applied Physics Letters · doi:10.1063/1.1394719 · Cited by 114
Cited by
A Review of the Terahertz Conductivity of Bulk and Nano-Materials
Lloyd-Hughes, J., & Jeon, T.-I. (2012) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-012-9905-y · Cited by 503
Self-citationTerahertz time-domain spectroscopy
Koch, M., Mittleman, D. M., Ornik, J., & Castro-Camus, E. (2023) · Nature Reviews Methods Primers · doi:10.1038/s43586-023-00232-z · Cited by 410
Self-citationTerahertz-time domain spectrometer with 90 dB peak dynamic range
Vieweg, N., Rettich, F., Deninger, A., Roehle, H., Dietz, R., Göbel, T., & Schell, M. (2014) · Journal of Infrared Millimeter and Terahertz Waves · doi:10.1007/s10762-014-0085-9 · Cited by 203
“played a dominant role in the SNR budget [26, 31].”
BackgroundPhotoconductive terahertz detectors with 105 dB peak dynamic range made of rhodium doped InGaAs
Kohlhaas, R. B., Breuer, S., Nellen, S., Liebermeister, L., Schell, M., Semtsiv, M. P., Masselink, W. T., & Globisch, B. (2019) · Applied Physics Letters · doi:10.1063/1.5095714 · Cited by 68
Chopra, N., & Lloyd-Hughes, J. (2025) · ACS Photonics · doi:10.1021/acsphotonics.4c01934 · Cited by 8
Self-citation
Metadata
- Authors
- Castro-Camus, E., Fu, L., Lloyd-Hughes, J., Tan, H. H., Jagadish, C., & Johnston, M. B.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2008-09-01
- Volume
- 104
- Issue
- 5
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2019122843
- Cited by
- 65
- References
- 3
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.