The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
PolLux: A new facility for soft x-ray spectromicroscopy at the Swiss Light Source
Open accessAbstract
We report on the successful installation and operation of a scanning transmission x-ray microspectroscope (STXM) at the PolLux facility at the Swiss Light Source. This integration of an advanced STXM with improved sample handling capabilities and a novel beamline provides unique capabilities. PolLux uses linearly or circularly polarized x-rays from a bending magnet with an extended photon energy range (200–1400 eV). It is therefore well suited to determine a sample’s quantitative chemical composition, molecular orientation, or thickness of organic as well as condensed matter materials. The local magnetic state of magnetic thin films is accessible through fast helicity switching by steering the electron beam off axis through the bending magnet. Ex vacuo girder movers allow fast and highly reproducible (<1 μm) alignment of the instrument with respect to the photon beam. The present spatial resolution is ∼20 nm, limited by the zone plates utilized. The instrument has the stability and positional resolution to operate with much higher resolution optics as it becomes available. In addition to characterization experiments, we present several typical examples from materials research and environmental science to exemplify the capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285
Microbubbles in medical imaging: current applications and future directions
Lindner, J. R. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1417 · Cited by 872
Magnetic vortex core reversal by excitation with short bursts of an alternating field
Van Waeyenberge, B., Puzic, A., Stoll, H., Chou, K. W., Tyliszczak, T., Hertel, R., Fähnle, M., Brückl, H., Rott, K., Reiss, G., et al. (2006) · Nature · doi:10.1038/nature05240 · Cited by 861
Self-citationInterferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source
Kilcoyne, A. L. D., Tyliszczak, T., Steele, W. F., Fakra, S., Hitchcock, P., Franck, K., Anderson, E., Harteneck, B., Rightor, E. G., Mitchell, G. E., et al. (2003) · Journal of Synchrotron Radiation · doi:10.1107/s0909049502017739 · Cited by 692
Self-citationSoft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672
Chemical Contrast in X-Ray Microscopy and Spatially Resolved XANES Spectroscopy of Organic Specimens
Ade, H., Zhang, X., Cameron, S., Costello, C., Kirz, J., & Williams, S. (1992) · Science · doi:10.1126/science.1439809 · Cited by 373
Self-citationUrquhart, S. G., & Ade, H. (2002) · The Journal of Physical Chemistry B · doi:10.1021/jp0255379 · Cited by 299
Self-citationCalibrated NEXAFS spectra of some common polymers
Dhez, O., Ade, H., & Urquhart, S. G. (2003) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/s0368-2048(02)00237-2 · Cited by 298
Self-citationAde, H., & Hitchcock, A. P. (2008) · Polymer · doi:10.1016/j.polymer.2007.10.030 · Cited by 286
Self-citationSoft X-ray spectromicroscopy beamline at the CLS: Commissioning results
Kaznatcheev, K. V., Karunakaran, C., Lanke, U. D., Urquhart, S. G., Obst, M., & Hitchcock, A. P. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.08.083 · Cited by 250
Targeted imaging using ultrasound
Dayton, P. A., & Ferrara, K. W. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10173 · Cited by 233
Cluster analysis of soft X-ray spectromicroscopy data
Lerotic, M., Jacobsen, C., Schäfer, T., & Vogt, S. (2004) · Ultramicroscopy · doi:10.1016/j.ultramic.2004.01.008 · Cited by 201
Time-Resolved Imaging of Spin Transfer Switching: Beyond the Macrospin Concept
Acremann, Y., Strachan, J. P., Chembrolu, V., Andrews, S. D., Tyliszczak, T., Katine, J. A., Carey, M. J., Clemens, B. M., Siegmann, H. C., & Stöhr, J. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.217202 · Cited by 176
Self-citationSchumacher, M., Christl, I., Scheinost, A. C., Jacobsen, C., & Kretzschmar, R. (2005) · Environmental Science & Technology · doi:10.1021/es050099f · Cited by 160
Exceptional preservation of fossil plant spores in high-pressure metamorphic rocks
Bernard, S., Benzerara, K., Beyssac, O., Menguy, N., Guyot, F., BROWNJR, G., & Goffé, B. (2007) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2007.07.041 · Cited by 151
Hopkins, R. J., Tivanski, A. V., Marten, B. D., & Gilles, M. K. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.03.009 · Cited by 133
Carbon speciation in airborne particulate matter with C (1s) NEXAFS spectroscopy
Braun, A. (2005) · Journal of Environmental Monitoring · doi:10.1039/b508910g · Cited by 67
The PolLux Microspectroscopy Beam line at the Swiss Light Source
Flechsig, U., Quitmann, C., Raabe, J., Böge, M., Fink, R., & Ade, H. W. (2007) · AIP conference proceedings · doi:10.1063/1.2436109 · Cited by 47
Self-citationScanning soft X-ray spectromicroscopy at the Pohang Light Source: commissioning results
Shin, H., & Lee, M. K. (2001) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(01)00517-4 · Cited by 18
The new scanning transmission X-ray microscope at BESSY II
Wiesemann, U. (2000) · AIP conference proceedings · doi:10.1063/1.1291185 · Cited by 17
Kenney, J. M., Morrison, G. R., Browne, M. T., et al. (1989) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/22/4/006 · Cited by 14
Twinmic: A European twin microscope station combining full-field imaging and scanning microscopy
Kaulich, B., Bacescu, D., Cocco, D., et al. (2003) · Journal de Physique IV (Proceedings) · doi:10.1051/jp4:200300039 · Cited by 14
Soft x‐ray microscopy at the NSLS
Beetz, T., Feser, M., Fleckenstein, H., et al. (2003) · Synchrotron Radiation News · doi:10.1080/08940880308603016 · Cited by 8
Cited by
Liati, A., Schreiber, D., Alpert, P. A., Liao, Y., Brem, B. T., Corral Arroyo, P., Hu, J., Jonsdottir, H. R., Ammann, M., & Dimopoulos Eggenschwiler, P. (2019) · Environmental Pollution · doi:10.1016/j.envpol.2019.01.078 · Cited by 75
Foetisch, A., Filella, M., Watts, B., Vinot, L.-H., & Bigalke, M. (2022) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.127804 · Cited by 58
He, X., Mukherjee, S., Watkins, S., Chen, M., Qin, T., Thomsen, L., Ade, H., & McNeill, C. R. (2014) · The Journal of Physical Chemistry C · doi:10.1021/jp501222w · Cited by 44
Self-citationFoetisch, A., Filella, M., Watts, B., Bragoni, M., & Bigalke, M. (2023) · Microplastics and Nanoplastics · doi:10.1186/s43591-023-00066-2 · Cited by 21
Metadata
- Authors
- Raabe, J., Tzvetkov, G., Flechsig, U., Böge, M., Jaggi, A., Sarafimov, B., Vernooij, M. G. C., Huthwelker, T., Ade, H., Kilcoyne, D., Tyliszczak, T., Fink, R. H., & Quitmann, C.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2008-11-01
- Volume
- 79
- Issue
- 11
- Pages
- 113704-113704
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2018951073
- Cited by
- 269
- References
- 23
- FWCI
- 15.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.