The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Targeted imaging using ultrasound
Open accessAbstract
The discipline of medical imaging is expanding to include both traditional anatomic modalities and new techniques for the functional assessment of the presence and extent of disease. Current FDA‐approved ultrasound contrast agents are micron‐sized bubbles with a stabilizing shell. Microbubble contrast agents can be used to estimate microvascular flow rate in a manner similar to dynamic contrast‐enhanced magnetic resonance imaging (MRI). The concentration of these agents within the vasculature, reticulo‐endothelial, or lymphatic systems produces an effective passive targeting of these areas. Liquid‐filled nanoparticles and liposomes have also demonstrated echogenicity and are under evaluation as ultrasound contrast agents. Actively targeted ultrasound relies on specially designed contrast agents to localize the targeted molecular signature or physiologic system. These agents typically remain within the vascular space, and therefore possible targets include molecular markers on thrombus, endothelial cells, and leukocytes. The purpose of this review is to summarize the requirements, challenges, current progress, and future directions of targeted imaging with ultrasound. J. Magn. Reson. Imaging 2002;16:362–377. © 2002 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adhesion receptors of the immune system
Springer, T. A. (1990) · Nature · doi:10.1038/346425a0 · Cited by 6,477
RGD AND OTHER RECOGNITION SEQUENCES FOR INTEGRINS
Ruoslahti, E. (1996) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.12.1.697 · Cited by 3,191
Flacke, S., Fischer, S., Scott, M. J., Fuhrhop, R. J., Allen, J. S., McLean, M., Winter, P., Sicard, G. A., Gaffney, P. J., Wickline, S. A., et al. (2001) · Circulation · doi:10.1161/hc3601.094303 · Cited by 515
A Novel Site-Targeted Ultrasonic Contrast Agent With Broad Biomedical Application
Lanza, G. M., Wallace, K. D., Scott, M. J., Cacheris, W. P., Abendschein, D. R., Christy, D. H., Sharkey, A. M., Miller, J. G., Gaffney, P. J., & Wickline, S. A. (1996) · Circulation · doi:10.1161/01.cir.94.12.3334 · Cited by 406
Cited by
New-Concept Chemotherapy by Nanoparticles of Biodegradable Polymers: Where Are We Now?
Feng, S.-S. (2006) · Nanomedicine · doi:10.2217/17435889.1.3.297 · Cited by 1,951
Nanotech approaches to drug delivery and imaging
Sahoo, S. K., & Labhasetwar, V. (2003) · Drug Discovery Today · doi:10.1016/s1359-6446(03)02903-9 · Cited by 1,203
Schutt, E. G., Klein, D. H., Mattrey, R. M., & Riess, J. G. (2003) · Angewandte Chemie International Edition · doi:10.1002/anie.200200550 · Cited by 543
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Drug-loaded nano/microbubbles for combining ultrasonography and targeted chemotherapy
Gao, Z., Kennedy, A. M., Christensen, D. A., & Rapoport, N. Y. (2008) · Ultrasonics · doi:10.1016/j.ultras.2007.11.002 · Cited by 316
Metadata
- Authors
- Dayton, P. A., & Ferrara, K. W.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2002-09-25
- Volume
- 16
- Issue
- 4
- Pages
- 362-377
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2063484869
- Cited by
- 233
- References
- 4
- FWCI
- 12.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Targeted imaging using ultrasound. https://app.cochat.ai/papers/10.1002/jmri.10173
- The paper
- Dayton, P. A., & Ferrara, K. W. (2002). Targeted imaging using ultrasound. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.10173
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.