Analyzing shear stress-induced alignment of actin filaments in endothelial cells with a microfluidic assay
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The physiology of vascular endothelial cells is strongly affected by fluid shear stress on their surface. In this study, a microfluidic assay was employed to analyze the alignment of actin filaments in endothelial cells in response to shear stress. When cells were cultured in microfluidic channels and subjected to shear stress, the alignment of filaments in the channel direction was significantly higher than in static cultures. By adding inhibitory drugs, the roles of several signaling proteins in the process of alignment were determined. Thus, it is shown how microfluidic technology can be employed to provide a mechanistic insight into cell physiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Cited by
Griep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
Self-citationLee, H., & Cho, D.-W. (2016) · Lab on a Chip · doi:10.1039/c6lc00450d · Cited by 363
Microfluidic organ-on-chip technology for blood-brain barrier research
van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2016) · Tissue Barriers · doi:10.1080/21688370.2016.1142493 · Cited by 333
Self-citationOrgans-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Metadata
- Authors
- van der Meer, A. D., Poot, A. A., Feijen, J., & Vermes, I.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2010-03
- Volume
- 4
- Issue
- 1
- Pages
- 011103
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2086088255
- Cited by
- 108
- References
- 1
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analyzing shear stress-induced alignment of actin filaments in endothelial cells with a microfluidic assay. https://app.cochat.ai/papers/10.1063/1.3366720
- The paper
- van der Meer, A. D., Poot, A. A., Feijen, J., & Vermes, I. (2010). Analyzing shear stress-induced alignment of actin filaments in endothelial cells with a microfluidic assay. Biomicrofluidics. https://doi.org/10.1063/1.3366720
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.