The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Oxygen plasma treatment for reducing hydrophobicity of a sealed polydimethylsiloxane microchannel
Open accessAbstract
Rapid prototyping of polydimethylsiloxane (PDMS) is often used to build microfluidic devices. However, the inherent hydrophobic nature of the material limits the use of PDMS in many applications. While different methods have been developed to transform the hydrophobic PDMS surface to a hydrophilic surface, the actual implementation proved to be time consuming due to differences in equipment and the need for characterization. This paper reports a simple and easy protocol combining a second extended oxygen plasma treatments and proper storage to produce usable hydrophilic PDMS devices. The results show that at a plasma power of 70 W, an extended treatment of over 5 min would allow the PDMS surface to remain hydrophilic for more than 6 h. Storing the treated PDMS devices in de-ionized water would allow them to maintain their hydrophilicity for weeks. Atomic force microscopy analysis shows that a longer oxygen plasma time produces a smoother surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Poly(dimethylsiloxane) as a Material for Fabricating Microfluidic Devices
McDonald, J. C., & Whitesides, G. M. (2002) · Accounts of Chemical Research · doi:10.1021/ar010110q · Cited by 2,454
Microfluidic methods for generating continuous droplet streams
Christopher, G. F., & Anna, S. L. (2007) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/40/19/r01 · Cited by 860
Bhattacharya, S., Datta, A., Berg, J. M., & Gangopadhyay, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844746 · Cited by 859
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
Polyethylene glycol-coated biocompatible surfaces
Alcantar, N. A., Aydil, E. S., & Israelachvili, J. N. (2000) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(20000905)51:3<343::aid-jbm7>3.0.co;2-d · Cited by 634
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Hillborg, H., Ankner, J. F., Gedde, U. W., Smith, G. D., Yasuda, H. K., & Wikström, K. (2000) · Polymer · doi:10.1016/s0032-3861(00)00039-2 · Cited by 511
On the aging of oxygen plasma-treated polydimethylsiloxane surfaces
Morra, M., Occhiello, E., Marola, R., Garbassi, F., Humphrey, P., & Johnson, D. (1990) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(90)90038-p · Cited by 477
Fabrication of microfluidic devices using polydimethylsiloxane
Friend, J., & Yeo, L. (2010) · Biomicrofluidics · doi:10.1063/1.3259624 · Cited by 425
Plasma treatment of polydimethylsiloxane
Owen, M. J., & Smith, P. J. (1994) · Journal of Adhesion Science and Technology · doi:10.1163/156856194x00942 · Cited by 410
Thermal aging and reduced hydrophobic recovery of polydimethylsiloxane
Eddington, D. T., Puccinelli, J. P., & Beebe, D. J. (2006) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2005.04.037 · Cited by 330
Tóth, A., Bertóti, I., Blazsó, M., Bánhegyi, G., Bognar, A., & Szaplonczay, P. (1994) · Journal of Applied Polymer Science · doi:10.1002/app.1994.070520914 · Cited by 168
Kim, J., Chaudhury, M. K., Owen, M. J., & Orbeck, T. (2001) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2001.7909 · Cited by 159
Xiao, D., Zhang, H., & Wirth, M. J. (2002) · Langmuir · doi:10.1021/la0205553 · Cited by 158
Fabrication of reconfigurable protein matrices by cracking
Zhu, X. A., Mills, K. L., Peters, P. R., Bahng, J. H., Liu, E. H., Shim, J., Naruse, K., CSETE, M. E., Thouless, M. D., & Takayama, S. (2005) · Nature Materials · doi:10.1038/nmat1365 · Cited by 138
The Stability of Radio-Frequency Plasma-Treated Polydimethylsiloxane Surfaces
Chen, I.-J., & Lindner, E. (2007) · Langmuir · doi:10.1021/la0627720 · Cited by 123
Microfabricated devices for fluid mixing and their application for chemical synthesis
Kakuta, M., Bessoth, F. G., & Manz, A. (2001) · The Chemical Record · doi:10.1002/tcr.1023 · Cited by 112
Cited by
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
3D Printing of Transparent and Conductive Heterogeneous Hydrogel–Elastomer Systems
Tian, K., Bae, J., Bakarich, S. E., Yang, C., Gately, R. D., Spinks, G. M., in het Panhuis, M., Suo, Z., & Vlassak, J. J. (2017) · Advanced Materials · doi:10.1002/adma.201604827 · Cited by 419
Active droplet sorting in microfluidics: a review
Xi, H.-D., Zheng, H., Guo, W., Gañán-Calvo, A. M., Ai, Y., Tsao, C.-W., Zhou, J., Li, W., Huang, Y., Nguyen, N.-T., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01435f · Cited by 369
Self-citationTsao, C.-W. (2016) · Micromachines · doi:10.3390/mi7120225 · Cited by 367
Metadata
- Authors
- Tan, S. H., Nguyen, N.-T., Chua, Y. C., & Kang, T. G.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2010-09-01
- Volume
- 4
- Issue
- 3
- Pages
- 32204-32204
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W1965500282
- Cited by
- 440
- References
- 19
- FWCI
- 4.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.