Cited by 54Advanced X-ray Imaging TechniquesX-ray Spectroscopy and Fluorescence AnalysisParticle Accelerators and Free-Electron Lasers

High-performance soft x-ray spectromicroscopy beamline at SSRF

Xue, Chaofan, Wang, Yong, Guo, Zhi, Wu, Yanqing, Zhen, Xiangjun, Chen, Min, Chen, Jiahua, Xue, Song +3 more·2010·Review of Scientific Instruments

Abstract

The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source, a plane grating monochromator, and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline, with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm.

Integrity signals

Registry

Crossref · 10.1063/1.3491837

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Xue, C., Wang, Y., Guo, Z., Wu, Y., Zhen, X., Chen, M., Chen, J., Xue, S., Peng, Z., Lu, Q., & Tai, R.
Affiliations
  • Chinese Academy of Sciences (CN)
  • Chinese Academy of Sciences 1 Shanghai Institute of Applied Physics, , Shanghai Synchrotron Radiation Facility, Shanghai 201800, China
  • Chinese Academy of Sciences 2 Changchun Institute of Optics, Fine Mechanics and Physics, , Changchun 130033, China
Venue
Review of Scientific Instruments
Published
2010-10-01
Volume
81
Issue
10
Pages
103502-103502
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2038630857
Cited by
54
References
22
Citations by year
2026: 2 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 7 · 2018: 3 · 2017: 6 · 2016: 7 · 2015: 7 · 2014: 1 · 2013: 5 · 2012: 2
FWCI
2.14
Type
journal article
Language
en
Open access
closed
Locations
  • Review of Scientific Instruments (publishedVersion)
  • PubMed (publishedVersion)
Funders
University of Warwick
Topics
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
  • Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Particle Accelerators and Free-Electron Lasers
Keywords
soft X-ray spectromicroscopy, synchrotron beamlines, Shanghai Synchrotron Radiation Facility, elliptically polarized undulator, plane grating monochromator, spatial resolution

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.