High-performance soft x-ray spectromicroscopy beamline at SSRF
Abstract
The Shanghai Synchrotron Radiation Facility (SSRF) is the first third-generation synchrotron facility in China and operated at an electron energy of 3.5 GeV. One of the seven beamlines in the first construction phase is devoted to soft x-ray spectromicroscopy and is equipped with an elliptically polarized undulator light source, a plane grating monochromator, and a scanning transmission x-ray microscope end station. Initial results reveal the high performance of this beamline, with an energy resolving power estimated to be over 10 000 at the argon L-edge and a spatial resolution better than 30 nm.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
Magnetic vortex core reversal by excitation with short bursts of an alternating field
Waeyenberge, B. V., Puzic, A., Stoll, H., Chou, K. W., Tyliszczak, T., Hertel, R., Fähnle, M., Brückl, H., Rott, K., Reiß, G., et al. (2006) · Nature · doi:10.1038/nature05240 · Cited by 861 · see citing works
Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source
Kilcoyne, A. L. D., Tyliszczak, T., Steele, W. F., Fakra, S. C., Hitchcock, P., Franck, K. D., Anderson, E. H., Harteneck, B. D., Rightor, E. G., Mitchell, G. E., et al. (2003) · Journal of Synchrotron Radiation · doi:10.1107/s0909049502017739 · Cited by 692 · see citing works
KING, G. C., Tronc, M., Read, F. H., et al. (1977) · Journal of Physics B Atomic and Molecular Physics · doi:10.1088/0022-3700/10/12/026 · Cited by 483 · see citing works
K-shell excitation spectra of CO, N2 and O2
Hitchcock, A. P., & Brion, C. E. (1980) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(80)80001-6 · Cited by 371 · see citing works
The plane grating and elliptical mirror: A new optical configuration for monochromators
Petersen, H. (1982) · Optics Communications · doi:10.1016/0030-4018(82)90040-2 · Cited by 256 · see citing works
Soft X-ray spectromicroscopy beamline at the CLS: Commissioning results
Kaznatcheev, K., Karunakaran, C., Lanke, U. D., et al. (2007) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2007.08.083 · Cited by 253 · see citing works
Reference energies for inner shell electron energy-loss spectroscopy
Sodhi, R. N. S., & Brion, C. E. (1984) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/0368-2048(84)80050-x · Cited by 249 · see citing works
Time-Resolved Imaging of Spin Transfer Switching: Beyond the Macrospin Concept
Acremann, Y., Strachan, J. P., Chembrolu, V., et al. (2006) · Physical Review Letters · doi:10.1103/physrevlett.96.217202 · Cited by 178 · see citing works
Exceptional preservation of fossil plant spores in high-pressure metamorphic rocks
Bernard, S., Benzerara, K., Beyssac, O., Menguy, N., Guyot, F., BROWNJR, G., & Goffé, B. (2007) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2007.07.041 · Cited by 151 · see citing works
A critical comparison of selected 1s and 2p core hole widths
Prince, K. C., Vondráček, M., Karvonen, J., Coreno, M., Camilloni, R., Avaldi, L., & de Simone, M. (1999) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/s0368-2048(98)00436-8 · Cited by 129 · see citing works
Carbon speciation in airborne particulate matter with C (1s) NEXAFS spectroscopy
Braun, A. (2005) · Journal of Environmental Monitoring · doi:10.1039/b508910g · Cited by 69 · see citing works
Kato, M., Morishita, Y., Oura, M., et al. (2007) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2007.06.003 · Cited by 61 · see citing works
Zhang, X. Z., Xu, Z., Tai, R., et al. (2010) · Journal of Synchrotron Radiation · doi:10.1107/s0909049510031250 · Cited by 53 · see citing works
Self-citationPimpale, A. V., Deshpande, S. K., & Bhide, V. G. (1991) · Applied Optics · doi:10.1364/ao.30.001591 · Cited by 22 · see citing works
Scanning soft X-ray spectromicroscopy at the Pohang Light Source: commissioning results
Shin, H., & Lee, M. K. (2001) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(01)00517-4 · Cited by 18 · see citing works
A new monochromator for the energy range 5 ⩽ ω ⩽ 1000
Jark, W. H., Haelbich, R. ‐., Hogrefe, H., et al. (1983) · Nuclear Instruments and Methods in Physics Research · doi:10.1016/0167-5087(83)91142-0 · Cited by 17 · see citing works
The new scanning transmission X-ray microscope at BESSY II
Wiesemann, U. (2000) · AIP conference proceedings · doi:10.1063/1.1291185 · Cited by 17 · see citing works
Kenney, J. M., Morrison, G. R., Browne, M. T., et al. (1989) · Journal of Physics E Scientific Instruments · doi:10.1088/0022-3735/22/4/006 · Cited by 14 · see citing works
Twinmic: A European twin microscope station combining full-field imaging and scanning microscopy
Kaulich, B., Bacescu, D., Cocco, D., et al. (2003) · Journal de Physique IV (Proceedings) · doi:10.1051/jp4:200300039 · Cited by 14 · see citing works
Soft x‐ray microscopy at the NSLS
Beetz, T., Feser, M., Fleckenstein, H., et al. (2003) · Synchrotron Radiation News · doi:10.1080/08940880308603016 · Cited by 8 · see citing works
Study of automobile exhaust particles by spectromicroscopy
Yang, C., Guo, Z., Xz, Z., et al. (2010) · doi:10.13538/j.1001-8042/nst.21.261-265 · Cited by 2 · see citing works
Self-citationSRN 98: XII National conference on synchrotron radiation application
Kuzin, M. V. (1999) · Synchrotron Radiation News · doi:10.1080/08940889908260966 · Cited by 1 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Nrf2 attenuates ferroptosis-mediated IIR-ALI by modulating TERT and SLC7A11
Dong, H., Xia, Y., Jin, S., Xue, C., Wang, Y., Hu, R., & Jiang, H. (2021) · Cell Death & Disease · doi:10.1038/s41419-021-04307-1 · Cited by 196 · see citing works
Self-citationExtreme ultraviolet lithography
Kazazis, D., Santaclara, J. G., van Schoot, J., Mochi, I., & Ekinci, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00361-z · Cited by 149 · see citing works
Interference lithography at EUV and soft X-ray wavelengths: Principles, methods, and applications
Mojarad, N., Gobrecht, J., & Ekinci, Y. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2015.03.047 · Cited by 114 · see citing works
- Authors
- Xue, C., Wang, Y., Guo, Z., Wu, Y., Zhen, X., Chen, M., Chen, J., Xue, S., Peng, Z., Lu, Q., & Tai, R.
- Affiliations
- Chinese Academy of Sciences (CN)
- Chinese Academy of Sciences 1 Shanghai Institute of Applied Physics, , Shanghai Synchrotron Radiation Facility, Shanghai 201800, China
- Chinese Academy of Sciences 2 Changchun Institute of Optics, Fine Mechanics and Physics, , Changchun 130033, China
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2010-10-01
- Volume
- 81
- Issue
- 10
- Pages
- 103502-103502
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2038630857
- Cited by
- 54
- References
- 22
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 3 · 2020: 2 · 2019: 7 · 2018: 3 · 2017: 6 · 2016: 7 · 2015: 7 · 2014: 1 · 2013: 5 · 2012: 2
- FWCI
- 2.14
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Warwick
- Topics
- Physical Sciences › Physics and Astronomy › Radiation › Advanced X-ray Imaging Techniques
- Physical Sciences › Physics and Astronomy › Radiation › X-ray Spectroscopy and Fluorescence Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Particle Accelerators and Free-Electron Lasers
- Keywords
- soft X-ray spectromicroscopy, synchrotron beamlines, Shanghai Synchrotron Radiation Facility, elliptically polarized undulator, plane grating monochromator, spatial resolution
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review