Microfluidic endothelial cell culture model to replicate disturbed flow conditions seen in atherosclerosis susceptible regions
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Atherosclerotic lesions occur non-randomly at vascular niches in bends and bifurcations where fluid flow can be characterized as “disturbed” (low shear stress with both forward and retrograde flow). Endothelial cells (ECs) at these locations experience significantly lower average shear stress without change in the levels of pressure or strain, which affects the local balance in mechanical stresses. Common in vitro models of atherosclerosis focus primarily on shear stress without accounting for pressure and strain loading. To overcome this limitation, we used our microfluidic endothelial cell culture model (ECCM) to achieve accurate replication of pressure, strain, and shear stress waveforms associated with both normal flow seen in straight sections of arteries and disturbed flow seen in the abdominal aorta in the infrarenal segment at the wall distal to the inferior mesenteric artery (IMA), which is associated with high incidence of atherosclerotic lesion formation. Human aortic endothelial cells (HAECs) were cultured within the ECCM under both normal and disturbed flow and evaluated for cell shape, cytoskeletal alignment, endothelial barrier function, and inflammation using immunofluorescence microscopy and flow cytometry. Results clearly demonstrate quantifiable differences between cells cultured under disturbed flow conditions, which are cuboidal with short and randomly oriented actin microfilaments and show intermittent expression of β-Catenin and cells cultured under normal flow. However, in the absence of pro-inflammatory stimulation, the levels of expression of activation markers: intra cellular adhesion molecule-1 (ICAM-1), vascular cell adhesion molecule-1 (VCAM-1), platelet endothelial cell adhesion molecule-1 (PECAM-1), and vascular endothelial cell growth factor – receptor 2 (VEGF-R2) known to be involved in the initiation of plaque formation were only slightly higher in HAECs cultured under disturbed flow in comparison to cells cultured under normal flow.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Cited by
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272
Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology
Dessalles, C. A., Leclech, C., Castagnino, A., & Barakat, A. I. (2021) · Communications Biology · doi:10.1038/s42003-021-02285-w · Cited by 230
Costa, P. F., Albers, H. J., Linssen, J. E. A., Middelkamp, H. H. T., van der Hout, L., Passier, R., van den Berg, A., Malda, J., & van der Meer, A. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00202e · Cited by 226
Khodabandehlou, K., Masehi-Lano, J. J., Poon, C., Wang, J., & Chung, E. J. (2017) · Experimental Biology and Medicine · doi:10.1177/1535370217693116 · Cited by 91
Thrombosis-on-a-chip: prospective impact of microphysiological models of vascular thrombosis
Pandian, N. K. R., Mannino, R. G., Lam, W. A., & Jain, A. (2018) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.12.001 · Cited by 56
Shin, Y., Lim, S., Kim, J., Jeon, J. S., Yoo, H., & Gweon, B. (2019) · Lab on a Chip · doi:10.1039/c9lc00352e · Cited by 26
Metadata
- Authors
- Estrada, R., Giridharan, G. A., Nguyen, M.-D., Prabhu, S. D., & Sethu, P.
- Venue
- Biomicrofluidics
- Publisher
- AIP Publishing
- Published
- 2011-09-01
- Volume
- 5
- Issue
- 3
- Pages
- 32006-3200611
- ISSN
- 1932-1058 (ISSN-L)
- OpenAlex
- W2073723194
- Cited by
- 75
- References
- 1
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.