The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
Abstract
The vibrational characteristics of a cantilever beam are well known to strongly depend on the fluid in which the beam is immersed. In this paper, we present a detailed theoretical analysis of the frequency response of a cantilever beam, that is immersed in a viscous fluid and excited by an arbitrary driving force. Due to its practical importance in application to the atomic force microscope (AFM), we consider in detail the special case of a cantilever beam that is excited by a thermal driving force. This will incorporate the presentation of explicit analytical formulae and numerical results, which will be of value to the users and designers of AFM cantilever beams.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions
McQuarrie, D. A. (1966) · American Journal of Physics · doi:10.1119/1.1972842 · Cited by 40,433
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Cited by
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Self-citationComparison of calibration methods for atomic-force microscopy cantilevers
Burnham, N. A., Chen, X., Hodges, C. S., Matei, G. A., Thoreson, E. J., Roberts, C. J., Davies, M. C., & Tendler, S. J. B. (2003) · Nanotechnology · doi:10.1088/0957-4484/14/1/301 · Cited by 458
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Rodrı́guez, T. R., & Garcı́a, R. (2004) · Applied Physics Letters · doi:10.1063/1.1642273 · Cited by 295
Monotonic Damping in Nanoscopic Hydration Experiments
Labuda, A., Kobayashi, K., Suzuki, K., Yamada, H., & Grütter, P. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.066102 · Cited by 38
Metadata
- Authors
- Sader, J. E.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1998-07-01
- Volume
- 84
- Issue
- 1
- Pages
- 64-76
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2023401067
- Cited by
- 1,410
- References
- 3
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope. https://app.cochat.ai/papers/10.1063/1.368002
- The paper
- Sader, J. E. (1998). Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope. Journal of Applied Physics. https://doi.org/10.1063/1.368002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.