The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Frequency response of cantilever beams immersed in viscous fluids with applications to the atomic force microscope
Abstract
The vibrational characteristics of a cantilever beam are well known to strongly depend on the fluid in which the beam is immersed. In this paper, we present a detailed theoretical analysis of the frequency response of a cantilever beam, that is immersed in a viscous fluid and excited by an arbitrary driving force. Due to its practical importance in application to the atomic force microscope (AFM), we consider in detail the special case of a cantilever beam that is excited by a thermal driving force. This will incorporate the presentation of explicit analytical formulae and numerical results, which will be of value to the users and designers of AFM cantilever beams.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Mathematical Functions
McQuarrie, D. A. (1966) · American Journal of Physics · doi:10.1119/1.1972842 · Cited by 40,433
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
An Introduction to Fluid Dynamics
Batchelor, G. K. (2000) · doi:10.1017/cbo9780511800955 · Cited by 12,360
LANDAU, L. D., & LIFSHITZ, E. M. (1951) · Cited by 5,903
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194
Formulas for Stress and Strain
Roark, R. J., Young, W. C., & Plunkett, R. (1976) · Journal of Applied Mechanics · doi:10.1115/1.3423917 · Cited by 1,927
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
The Special Functions and Their Approximations
Clenshaw, C. W., & Luke, Y. L. (1972) · Mathematics of Computation · doi:10.2307/2004747 · Cited by 1,457
MICRO-ELECTRO-MECHANICAL-SYSTEMS (MEMS) AND FLUID FLOWS
Ho, C.-M., & Tai, Y.-C. (1998) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.30.1.579 · Cited by 1,254
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
Self-citationMicrofabrication of cantilever styli for the atomic force microscope
Albrecht, T. R., Akamine, S., Carver, T. E., & Quate, C. F. (1990) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.576520 · Cited by 747
Short cantilevers for atomic force microscopy
Walters, D. A., Cleveland, J. P., Thomson, N. H., Hansma, P. K., Wendman, M. A., Gurley, G., & Elings, V. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147177 · Cited by 494
Studies of vibrating atomic force microscope cantilevers in liquid
Schäffer, T. E., Cleveland, J. P., Ohnesorge, F., Walters, D. A., & Hansma, P. K. (1996) · Journal of Applied Physics · doi:10.1063/1.363308 · Cited by 311
Scan speed limit in atomic force microscopy
BUTT, H. ‐., SIEDLE, P., SEIFERT, K., FENDLER, K., SEEGER, T., BAMBERG, E., WEISENHORN, A. L., GOLDIE, K., & ENGEL, A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03280.x · Cited by 233
Characterization of application-specific probes for SPMs:
Tortonese, M., & Kirk, M. (1997) · SPIE Proceedings · doi:10.1117/12.271229 · Cited by 181
Multi-mode noise analysis of cantilevers for scanning probe microscopy
Salapaka, M. V., Bergh, H. S., Lai, J., Majumdar, A., & McFarland, E. W. (1997) · Journal of Applied Physics · doi:10.1063/1.363955 · Cited by 153
Distance-dependent noise measurements in scanning force microscopy
Roters, A., & Johannsmann, D. (1996) · Journal of Physics Condensed Matter · doi:10.1088/0953-8984/8/41/006 · Cited by 86
Damping of piezoresistive silicon accelerometers
Tschan, T., de Rooij, N., & Bezinge, A. (1992) · Sensors and Actuators A Physical · doi:10.1016/0924-4247(92)80015-u · Cited by 13
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Self-citationDynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
The emergence of multifrequency force microscopy
Garcia, R., & Herruzo, E. T. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.38 · Cited by 577
Metadata
- Authors
- Sader, J. E.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1998-07-01
- Volume
- 84
- Issue
- 1
- Pages
- 64-76
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2023401067
- Cited by
- 1,410
- References
- 19
- FWCI
- 6.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.