CoChat

Terahertz radiation and the skin: a review

Open access
Nikitkina, Angelina I., Bikmulina, Polina Y., Gafarova, Elvira R., Kosheleva, Nastasia V., Efremov, Yuri M., Bezrukov, Evgeny A., Butnaru, Denis V., Dolganova, Irina N., Chernomyrdin, Nikita V., Cherkasova, Olga P., Gavdush, Arsenii A., Timashev, Peter S. · 2021 · Journal of Biomedical Optics
Cited by 173

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

SIGNIFICANCE: Terahertz (THz) radiation has demonstrated a great potential in biomedical applications over the past three decades, mainly due to its non-invasive and label-free nature. Among all biological specimens, skin tissue is an optimal sample for the application of THz-based methods because it allows for overcoming some intrinsic limitations of the technique, such as a small penetration depth (0.1 to 0.3 mm for the skin, on average). AIM: We summarize the modern research results achieved when THz technology was applied to the skin, considering applications in both imaging/detection and treatment/modulation of the skin constituents. APPROACH: We perform a review of literature and analyze the recent research achievements in THz applications for skin diagnosis and investigation. RESULTS: The reviewed results demonstrate the possibilities of THz spectroscopy and imaging, both pulsed and continuous, for diagnosis of skin melanoma and non-melanoma cancer, dysplasia, scars, and diabetic condition, mainly based on the analysis of THz optical properties. The possibility of modulating cell activity and treatment of various diseases by THz-wave exposure is shown as well. CONCLUSIONS: The rapid development of THz technologies and the obtained research results for skin tissue highlight the potential of THz waves as a research and therapeutic instrument. The perspectives on the use of THz radiation are related to both non-invasive diagnostics and stimulation and control of different processes in a living skin tissue for regeneration and cancer treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1117/1.jbo.26.4.043005

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 173

Metadata

Authors
Nikitkina, A. I., Bikmulina, P. Y., Gafarova, E. R., Kosheleva, N. V., Efremov, Y. M., Bezrukov, E. A., Butnaru, D. V., Dolganova, I. N., Chernomyrdin, N. V., Cherkasova, O. P., Gavdush, A. A., & Timashev, P. S.
Venue
Journal of Biomedical Optics
Published
2021-02-13
Volume
26
Issue
04
Pages
1-26
ISSN
1083-3668 (ISSN-L)
OpenAlex
W3132538708
Cited by
173
References
8
FWCI
8.79
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Terahertz radiation and the skin: a review. https://app.cochat.ai/papers/10.1117/1.jbo.26.4.043005
The paper
Nikitkina, A. I., Bikmulina, P. Y., Gafarova, E. R., Kosheleva, N. V., Efremov, Y. M., Bezrukov, E. A., Butnaru, D. V., Dolganova, I. N., Chernomyrdin, N. V., Cherkasova, O. P., Gavdush, A. A., & Timashev, P. S. (2021). Terahertz radiation and the skin: a review. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.26.4.043005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.