A magnetically shielded room with ultra low residual field and gradient
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
A versatile and portable magnetically shielded room with a field of (700 ± 200) pT within a central volume of 1 m × 1 m × 1 m and a field gradient less than 300 pT/m, achieved without any external field stabilization or compensation, is described. This performance represents more than a hundredfold improvement of the state of the art for a two-layer magnetic shield and provides an environment suitable for a next generation of precision experiments in fundamental physics at low energies; in particular, searches for electric dipole moments of fundamental systems and tests of Lorentz-invariance based on spin-precession experiments. Studies of the residual fields and their sources enable improved design of future ultra-low gradient environments and experimental apparatus. This has implications for developments of magnetometry beyond the femto-Tesla scale in, for example, biomagnetism, geosciences, and security applications and in general low-field nuclear magnetic resonance (NMR) measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CPT violation and the standard model
Colladay, D., & Kostelecký, V. A. (1997) · Physical Review D · doi:10.1103/physrevd.55.6760 · Cited by 1,779
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Trodden, M. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.1463 · Cited by 521
(2013) · doi:10.1017/cbo9780511846380 · Cited by 286
Cited by
Electric dipole moments of atoms, molecules, nuclei, and particles
Chupp, T. E., Fierlinger, P., Ramsey-Musolf, M. J., & Singh, J. T. (2019) · Reviews of Modern Physics · doi:10.1103/revmodphys.91.015001 · Cited by 450
Self-citationA lightweight magnetically shielded room with active shielding
Holmes, N., Rea, M., Chalmers, J., Leggett, J., Edwards, L. J., Nell, P., Pink, S., Patel, P., Wood, J., Murby, N., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-17346-1 · Cited by 121
Self-citationA 90-Channel Triaxial Magnetoencephalography System Using Optically Pumped Magnetometers
Rea, M., Boto, E., Holmes, N., Hill, R., Osborne, J., Rhodes, N., Leggett, J., Rier, L., Bowtell, R., Shah, V., et al. (2022) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14890 · Cited by 102
Minimizing magnetic fields for precision experiments
Altarev, I., Fierlinger, P., Lins, T., Marino, M. G., Nießen, B., Petzoldt, G., Reisner, M., Stuiber, S., Sturm, M., Taggart Singh, J., et al. (2015) · Journal of Applied Physics · doi:10.1063/1.4922671 · Cited by 66
Self-citationActive Magnetic-Field Stabilization with Atomic Magnetometer
Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H. (2020) · Sensors · doi:10.3390/s20154241 · Cited by 32
Metadata
- Authors
- Altarev, I., Babcock, E., Beck, D., Burghoff, M., Chesnevskaya, S., Chupp, T., Degenkolb, S., Fan, I., Fierlinger, P., Frei, A., Gutsmiedl, E., Knappe-Grüneberg, S., Kuchler, F., Lauer, T., Link, P., Lins, T., Marino, M., McAndrew, J., Niessen, B., Paul, S., Petzoldt, G., Schläpfer, U., Schnabel, A., Sharma, S., Singh, J., Stoepler, R., Stuiber, S., Sturm, M., Taubenheim, B., Trahms, L., Voigt, J., & Zechlau, T.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2014-07-01
- Volume
- 85
- Issue
- 7
- Pages
- 075106-075106
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2011875433
- Cited by
- 107
- References
- 4
- FWCI
- 3.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.