CoChat

Comprehensive biocompatibility of nontoxic and high-output flexible energy harvester using lead-free piezoceramic thin film

Open access
Jeong, Chang Kyu, Han, Jae Hyun, Palneedi, Haribabu, Park, Hyewon, Hwang, Geon-Tae, Joung, Boyoung, Kim, Seong-Gon, Shin, Hong Ju, Kang, Il-Suk, Ryu, Jungho, Lee, Keon Jae · 2017 · APL Materials
Cited by 151

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Flexible piezoelectric energy harvesters have been regarded as an overarching candidate for achieving self-powered electronic systems for environmental sensors and biomedical devices using the self-sufficient electrical energy. In this research, we realize a flexible high-output and lead-free piezoelectric energy harvester by using the aerosol deposition method and the laser lift-off process. We also investigated the comprehensive biocompatibility of the lead-free piezoceramic device using ex-vivo ionic elusion and in vivo bioimplantation, as well as in vitro cell proliferation and histologic inspection. The fabricated LiNbO3-doped (K,Na)NbO3 (KNN) thin film-based flexible energy harvester exhibited an outstanding piezoresponse, and average output performance of an open-circuit voltage of ∼130 V and a short-circuit current of ∼1.3 μA under normal bending and release deformation, which is the best record among previously reported flexible lead-free piezoelectric energy harvesters. Although both the KNN and Pb(Zr,Ti)O3 (PZT) devices showed short-term biocompatibility in cellular and histological studies, excessive Pb toxic ions were eluted from the PZT in human serum and tap water. Moreover, the KNN-based flexible energy harvester was implanted into a porcine chest and generated up to ∼5 V and 700 nA from the heartbeat motion, comparable to the output of previously reported lead-based flexible energy harvesters. This work can compellingly serve to advance the development of piezoelectric energy harvesting for actual and practical biocompatible self-powered biomedical applications beyond restrictions of lead-based materials in long-term physiological and clinical aspects.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.4976803

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 151

Metadata

Authors
Jeong, C. K., Han, J. H., Palneedi, H., Park, H., Hwang, G.-T., Joung, B., Kim, S.-G., Shin, H. J., Kang, I.-S., Ryu, J., & Lee, K. J.
Venue
APL Materials
Published
2017-02-22
Volume
5
Issue
7
ISSN
2166-532X (ISSN-L)
OpenAlex
W2590948541
Cited by
151
References
6
FWCI
15.82
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comprehensive biocompatibility of nontoxic and high-output flexible energy harvester using lead-free piezoceramic thin film. https://app.cochat.ai/papers/10.1063/1.4976803
The paper
Jeong, C. K., Han, J. H., Palneedi, H., Park, H., Hwang, G.-T., Joung, B., Kim, S.-G., Shin, H. J., Kang, I.-S., Ryu, J., & Lee, K. J. (2017). Comprehensive biocompatibility of nontoxic and high-output flexible energy harvester using lead-free piezoceramic thin film. APL Materials. https://doi.org/10.1063/1.4976803

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.