Suppression of current source noise with an atomic magnetometer
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
This paper introduces a method for using an atomic magnetometer to suppress current source noise. In this method, the current noise is (i) suppressed with a lamp-pumped cesium atomic magnetometer and (ii) measured with a higher-sensitivity laser-pumped cesium atomic magnetometer. The current noise is compared before and after noise suppression at an output current of 50 mA, and the noise-suppression ratio is ∼27 dB. The noise-suppression performance can be enhanced by improving the sensitivity of the atomic magnetometer and the ability to restrain the ambient magnetic noise. This method has practical applications in metrology and fundamental physics research.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Normally, the magnetometer oscillates spontaneously at the Larmor frequency if the loop gain is unity and the loop phase shift is zero (50).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [50]
Citations
Cites
High-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Kitching, J. (2018) · Applied Physics Reviews · doi:10.1063/1.5026238 · Cited by 621
Chip-scale atomic magnetometer
Schwindt, P. D. D., Knappe, S., Shah, V., Hollberg, L., Kitching, J., Liew, L.-A., & Moreland, J. (2004) · Applied Physics Letters · doi:10.1063/1.1839274 · Cited by 481
Optically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Cates, G. D., Schaefer, S. R., & Happer, W. (1988) · Physical Review A · doi:10.1103/physreva.37.2877 · Cited by 298
Principles of Operation of the Rubidium Vapor Magnetometer
Bloom, A. L. (1962) · Applied Optics · doi:10.1364/ao.1.000061 · Cited by 282
High Sensitivity Magnetometers
(2017) · Smart Sensors, Measurement and Instrumentation · doi:10.1007/978-3-319-34070-8 · Cited by 201
Transverse spin relaxation in inhomogeneous magnetic fields
Stoller, S. D., Happer, W., & Dyson, F. J. (1991) · Physical Review A · doi:10.1103/physreva.44.7459 · Cited by 159
Nonlinear magneto-optical rotation with amplitude modulated light
Gawlik, W., Krzemień, L., Pustelny, S., Sangla, D., Zachorowski, J., Graf, M., Sushkov, A. O., & Budker, D. (2006) · Applied Physics Letters · doi:10.1063/1.2190457 · Cited by 107
Research works printed but not linked: 2
- 2007, Phase-Lock Basics
- 2013, Optical Magnetometry
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
Self-citationDual-Species All-Optical Magnetometer Based on a Cs-K Hybrid Vapor Cell
Ding, Y., Xiao, W., Zhao, Y., Wu, T., Peng, X., & Guo, H. M. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.034066 · Cited by 15
Self-citationDesign of Portable Self-Oscillating VCSEL-Pumped Cesium Atomic Magnetometer
Jin, K., Geng, X., Liang, Z., Tang, W., Xiao, J., Hu, H., Huang, G., Li, G., Yang, G., & Liang, S. (2022) · Electronics · doi:10.3390/electronics11223666 · Cited by 12
“Therefore, it is necessary to evaluate the performance of the magnetometer in an accurate magnetic field [28].”
BackgroundAn Unmanned Aerial Vehicle Magnetic Detection System for Archaeological Exploration
Yu, J., Li, J., Du, C., Peng, X., & Guo, H. (2025) · Electromagnetic Science · doi:10.23919/emsci.2025.0012 · Cited by 11
Self-citationGeng, X., Tang, W., Xie, A.-D., Xu, Z., Yang, G., Liang, S., Huang, H., Huang, G., & Li, G. (2025) · Optics Express · doi:10.1364/oe.574832 · Cited by 4
Metadata
- Authors
- Shen, L., Zhang, R., Wu, T., Peng, X., Yu, S., Chen, J., & Guo, H.
- Affiliations
- Beijing University of Posts and Telecommunications (CN)
- National University of Defense Technology (CN)
- Peking University (CN)
- Corresponding author
- Peng, Xiang
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2020-08-01
- Volume
- 91
- Issue
- 8
- Pages
- 084701-084701
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W3047322357
- Cited by
- 16
- References
- 27
- Citations by year
- 2026: 5 · 2025: 3 · 2023: 4 · 2022: 3 · 2021: 1
- FWCI
- 0.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Natural Science Foundation of China (61531003, 61571018)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Keywords
- noise reduction, atomic magnetometer, magnetometer sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Suppression of current source noise with an atomic magnetometer. https://app.cochat.ai/papers/10.1063/5.0009987
- The paper
- Shen, L., Zhang, R., Wu, T., Peng, X., Yu, S., Chen, J., & Guo, H. (2020). Suppression of current source noise with an atomic magnetometer. Review of Scientific Instruments. https://doi.org/10.1063/5.0009987
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.