Luminescence based temperature bio-imaging: Status, challenges, and perspectives
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The only way to get thermal images of living organisms without perturbing them is to use luminescent probes with temperature-dependent spectral properties. The acquisition of such thermal images becomes essential to distinguish various states of cells, to monitor thermogenesis, to study cellular activity, and to control hyperthermia therapy. Current efforts are focused on the development and optimization of luminescent reporters such as small molecules, proteins, quantum dots, and lanthanide-doped nanoparticles. However, much less attention is devoted to the methods and technologies that are required to image temperature distribution at both in vitro or in vivo levels. Indeed, rare examples can be found in the scientific literature showing technologies and materials capable of providing reliable 2D thermal images of living organisms. In this review article, examples of 2D luminescence thermometry are presented alongside new possibilities and directions that should be followed to achieve the required level of simplicity and reliability that ensure their future implementation at the clinical level. This review will inspire specialists in chemistry, physics, biology, medicine, and engineering to collaborate with materials scientists to jointly develop novel more accurate temperature probes and enable mapping of temperature with simplified technical means.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456
Molecular mechanism and physiological functions of clathrin-mediated endocytosis
McMahon, H. T., & Boucrot, E. (2011) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3151 · Cited by 2,223
Ke, G., Wang, C., Ge, Y., Zheng, N., Zhu, Z., & Yang, C. J. (2012) · Journal of the American Chemical Society · doi:10.1021/ja3082439 · Cited by 196
The role of tissue fluorescence in in vivo optical bioimaging
Lifante, J., Shen, Y., Ximendes, E., Martín Rodríguez, E., & Ortgies, D. H. (2020) · Journal of Applied Physics · doi:10.1063/5.0021854 · Cited by 43
Self-citation
Metadata
- Authors
- Bednarkiewicz, A., Drabik, J., Trejgis, K., Jaque, D., Ximendes, E., & Marciniak, L.
- Venue
- Applied Physics Reviews
- Publisher
- AIP Publishing
- Published
- 2021-03-01
- Volume
- 8
- Issue
- 1
- ISSN
- 1931-9401 (ISSN-L)
- OpenAlex
- W3134040072
- Cited by
- 158
- References
- 5
- FWCI
- 7.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Luminescence based temperature bio-imaging: Status, challenges, and perspectives. https://app.cochat.ai/papers/10.1063/5.0030295
- The paper
- Bednarkiewicz, A., Drabik, J., Trejgis, K., Jaque, D., Ximendes, E., & Marciniak, L. (2021). Luminescence based temperature bio-imaging: Status, challenges, and perspectives. Applied Physics Reviews. https://doi.org/10.1063/5.0030295
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.