A rapid method for the analysis of perfluorinated alkyl substances in serum by hybrid solid-phase extraction
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Environmental context: Although the environmental occurrence of perfluoroalkyl substances was first reported almost 20 years ago, there are continuing concerns about human exposure to these potentially toxic chemicals. Such concerns have necessitated the development of reliable methods for rapid determination of perfluoroalkyl substances in human serum. This article describes a rapid and sensitive analytical method suitable for monitoring human exposure to perfluoroalkyl substances. A method for the analysis of 13 perfluorinated alkyl substances (PFASs) in human serum was developed based on hybrid solid-phase extraction (hybrid-SPE) and ultrahigh-performance liquid chromatography–tandem mass spectrometry (UPLC-MS/MS). Serum PFASs were extracted using hybrid-SPE-phospholipid cartridge after precipitating proteins and other endogenous biological interferences with 1 % ammonium formate in methanol. The average intra-day accuracy (measured as percent recoveries from fortified samples) and precision of the method (measured as relative standard deviation [RSD, %] between analyses) were 88.7–117 % and 1.0–13.4 %, respectively. The average inter-day precision was 2.8–6.9 %. The method was sensitive, with limits of quantification (LOQs) in the range of 0.05 to 0.09 ng mL-1 for all 13 PFASs. The applicability of this method was tested by analysing serum-certified standard reference material and proficiency test samples. In an hour, 100 samples can be processed by hybrid-SPE, and the instrumental run time is 5 min per sample. The developed method is rapid, inexpensive, accurate, precise, and extremely sensitive for the analysis of PFASs in human serum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hu, X. C., Andrews, D. Q., Lindstrom, A. B., Bruton, T. A., Schaider, L. A., Grandjean, P., Lohmann, R., Carignan, C. C., Blum, A., Balan, S. A., et al. (2016) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.6b00260 · Cited by 1,333
Calafat, A. M., Wong, L.-Y., Kuklenyik, Z., Reidy, J. A., & Needham, L. L. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.10598 · Cited by 1,247
Perfluorooctanesulfonate and related fluorochemicals in human blood from several countries
Kannan, K., Corsolini, S., Falandysz, J., Fillmann, G., Kumar, K. S., Loganathan, B. G., Mohd, M. A., Olivero, J., Wouwe, N. V., Yang, J. H., et al. (2004) · Environmental Science & Technology · doi:10.1021/es0493446 · Cited by 1,056
Self-citationCompound-specific, quantitative characterization of organic fluorochemicals in biological matrices
Hansen, K. J., Clemen, L. A., Ellefson, M. E., & Johnson, H. O. (2001) · Environmental Science & Technology · doi:10.1021/es001489z · Cited by 923
Cited by
Oh, J., Shin, H.-M., Kannan, K., Calafat, A. M., Schmidt, R. J., Hertz-Picciotto, I., & Bennett, D. H. (2024) · Environmental Science & Technology · doi:10.1021/acs.est.3c08928 · Cited by 29
Self-citationTaibl, K. R., Liang, D., Dunlop, A. L., Barr, D. B., Smith, M. R., Steenland, K., Tan, Y., Ryan, P. B., Panuwet, P., Everson, T., et al. (2023) · Environmental Pollution · doi:10.1016/j.envpol.2023.121331 · Cited by 28
Self-citationThompson, M., Eatman, J. A., Dunlop, A. L., Barr, D. B., Kannan, K., Corwin, E. J., Ryan, P. B., Panuwet, P., Yakimavets, V., Taibl, K. R., et al. (2024) · Chemosphere · doi:10.1016/j.chemosphere.2024.142052 · Cited by 9
Self-citation
Metadata
- Authors
- Honda, M., Robinson, M., & Kannan, K.
- Venue
- Environmental Chemistry
- Publisher
- CSIRO Publishing
- Published
- 2018-05-08
- Volume
- 15
- Issue
- 2
- Pages
- 92-99
- ISSN
- 1448-2517 (ISSN-L)
- 1449-8979
- OpenAlex
- W2801125508
- Cited by
- 72
- References
- 4
- FWCI
- 2.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.