The DOI matches its Crossref record.
Scanning electron microscopy of cells and tissues under fully hydrated conditions
Open accessAbstract
A capability for scanning electron microscopy of wet biological specimens is presented. A membrane that is transparent to electrons protects the fully hydrated sample from the vacuum. The result is a hybrid technique combining the ease of use and ability to see into cells of optical microscopy with the higher resolution of electron microscopy. The resolution of low-contrast materials is ≈100 nm, whereas in high-contrast materials the resolution can reach 10 nm. Standard immunogold techniques and heavy-metal stains can be applied and viewed in the fluid to improve the contrast. Images present a striking combination of whole-cell morphology with a wealth of internal details. A possibility for direct inspection of tissue slices transpires, imaging only the external layer of cells. Simultaneous imaging with photons excited by the electrons incorporates data on material distribution, indicating a potential for multilabeling and specific scintillating markers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The scanning electron microscope in microbiology and diagnosis of infectious disease
Golding, C. G., Lamboo, L. L., Beniac, D. R., & Booth, T. F. (2016) · Scientific Reports · doi:10.1038/srep26516 · Cited by 236
Graphene-enabled electron microscopy and correlated super-resolution microscopy of wet cells
Wojcik, M., Hauser, M., Li, W., Moon, S., & Xu, K. (2015) · Nature Communications · doi:10.1038/ncomms8384 · Cited by 133
Civitarese, A. E., MacLean, P. S., Carling, S., Kerr-Bayles, L., McMillan, R. P., Pierce, A., Becker, T. C., Moro, C., Finlayson, J., Lefort, N., et al. (2010) · Cell Metabolism · doi:10.1016/j.cmet.2010.04.004 · Cited by 95
Modulation of myocellular fat stores: lipid droplet dynamics in health and disease
Meex, R. C. R., Schrauwen, P., & Hesselink, M. K. C. (2009) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.91053.2008 · Cited by 65
Assessment of intramuscular triglycerides: contribution to metabolic abnormalities
Dubé, J., & Goodpaster, B. H. (2006) · Current Opinion in Clinical Nutrition & Metabolic Care · doi:10.1097/01.mco.0000241664.38385.12 · Cited by 31
Metadata
- Authors
- Thiberge, S., Nechushtan, A., Sprinzak, D., Gileadi, O., Behar, V., Zik, O., Chowers, Y., Michaeli, S., Schlessinger, J., & Moses, E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-02-26
- Volume
- 101
- Issue
- 10
- Pages
- 3346-3351
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2122390610
- Cited by
- 253
- References
- 0
- FWCI
- 6.26
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Scanning electron microscopy of cells and tissues under fully hydrated conditions. https://app.cochat.ai/papers/10.1073/pnas.0400088101
- The paper
- Thiberge, S., Nechushtan, A., Sprinzak, D., Gileadi, O., Behar, V., Zik, O., Chowers, Y., Michaeli, S., Schlessinger, J., & Moses, E. (2004). Scanning electron microscopy of cells and tissues under fully hydrated conditions. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0400088101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.