The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Bioreactor-based bone tissue engineering: The influence of dynamic flow on osteoblast phenotypic expression and matrix mineralization
Open accessAbstract
An important issue in tissue engineering concerns the possibility of limited tissue ingrowth in tissue-engineered constructs because of insufficient nutrient transport. We report a dynamic flow culture system using high-aspect-ratio vessel rotating bioreactors and 3D scaffolds for culturing rat calvarial osteoblast cells. 3D scaffolds were designed by mixing lighter-than-water (density, <1g/ml) and heavier-than-water (density, >1g/ml) microspheres of 85:15 poly(lactide- co -glycolide). We quantified the rate of 3D flow through the scaffolds by using a particle-tracking system, and the results suggest that motion trajectories and, therefore, the flow velocity around and through scaffolds in rotating bioreactors can be manipulated by varying the ratio of heavier-than-water to lighter-than-water microspheres. When rat primary calvarial cells were cultured on the scaffolds in bioreactors for 7 days, the 3D dynamic flow environment affected bone cell distribution and enhanced cell phenotypic expression and mineralized matrix synthesis within tissue-engineered constructs compared with static conditions. These studies provide a foundation for exploring the effects of dynamic flow on osteoblast function and provide important insight into the design and optimization of 3D scaffolds suitable in bioreactors for in vitro tissue engineering of bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Bone graft materials. An overview of the basic science.
Bauer, T. W., & Muschler, G. F. (2000) · PubMed · Cited by 1,073
Bone Graft Materials: An Overview of the Basic Science
Bauer, T. W., & Muschler, G. F. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00003 · Cited by 998
Bone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds
Ishaug, S. L., Crane, G. M., Miller, M. J., Yasko, A. W., Yaszemski, M. J., & Mikos, A. G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<17::aid-jbm3>3.0.co;2-o · Cited by 833
Three-dimensional culture of rat calvarial osteoblasts in porous biodegradable polymers
Ishaug-Riley, S. L., Crane-Kruger, G. M., Yaszemski, M. J., & Mikos, A. G. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00021-0 · Cited by 496
Goldstein, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00280-5 · Cited by 476
Chondrogenesis in a Cell-Polymer-Bioreactor System
Freed, L. E., Hollander, A. P., Martin, I., Barry, J. R., Langer, R., & Vunjak-Novakovic, G. (1998) · Experimental Cell Research · doi:10.1006/excr.1998.4010 · Cited by 433
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Self-citationLaurencin, C., Khan, Y., & El-Amin, S. F. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.49 · Cited by 716
Self-citationEngineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
Biomaterials for Bone Regenerative Engineering
Yu, X., Tang, X., Gohil, S. V., & Laurencin, C. T. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400760 · Cited by 418
Self-citationDatta, N., P. Pham, Q., Sharma, U., Sikavitsas, V. I., Jansen, J. A., & Mikos, A. G. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505661103 · Cited by 411
Metadata
- Authors
- Yu, X., Botchwey, E. A., Levine, E. M., Pollack, S. R., & Laurencin, C. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-07-26
- Volume
- 101
- Issue
- 31
- Pages
- 11203-11208
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2129086150
- Cited by
- 296
- References
- 32
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioreactor-based bone tissue engineering: The influence of dynamic flow on osteoblast phenotypic expression and matrix mineralization. https://app.cochat.ai/papers/10.1073/pnas.0402532101
- The paper
- Yu, X., Botchwey, E. A., Levine, E. M., Pollack, S. R., & Laurencin, C. T. (2004). Bioreactor-based bone tissue engineering: The influence of dynamic flow on osteoblast phenotypic expression and matrix mineralization. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0402532101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.