The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Bioreactor-based bone tissue engineering: The influence of dynamic flow on osteoblast phenotypic expression and matrix mineralization
Open accessAbstract
An important issue in tissue engineering concerns the possibility of limited tissue ingrowth in tissue-engineered constructs because of insufficient nutrient transport. We report a dynamic flow culture system using high-aspect-ratio vessel rotating bioreactors and 3D scaffolds for culturing rat calvarial osteoblast cells. 3D scaffolds were designed by mixing lighter-than-water (density, <1g/ml) and heavier-than-water (density, >1g/ml) microspheres of 85:15 poly(lactide- co -glycolide). We quantified the rate of 3D flow through the scaffolds by using a particle-tracking system, and the results suggest that motion trajectories and, therefore, the flow velocity around and through scaffolds in rotating bioreactors can be manipulated by varying the ratio of heavier-than-water to lighter-than-water microspheres. When rat primary calvarial cells were cultured on the scaffolds in bioreactors for 7 days, the 3D dynamic flow environment affected bone cell distribution and enhanced cell phenotypic expression and mineralized matrix synthesis within tissue-engineered constructs compared with static conditions. These studies provide a foundation for exploring the effects of dynamic flow on osteoblast function and provide important insight into the design and optimization of 3D scaffolds suitable in bioreactors for in vitro tissue engineering of bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosmann, T. (1983) · Journal of Immunological Methods · doi:10.1016/0022-1759(83)90303-4 · Cited by 56,104
Langer, R., & Vacanti, J. P. (1993) · Science · doi:10.1126/science.8493529 · Cited by 9,893
Calcium Phosphate Ceramics as Hard Tissue Prosthetics
JARCHO, M. (1981) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198106000-00037 · Cited by 2,014
A model for the excitation of osteocytes by mechanical loading-induced bone fluid shear stresses
Weinbaum, S., Cowin, S. C., & Zeng, Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90010-8 · Cited by 1,277
Bone graft materials. An overview of the basic science.
Bauer, T. W., & Muschler, G. F. (2000) · PubMed · Cited by 1,073
Bone Graft Materials: An Overview of the Basic Science
Bauer, T. W., & Muschler, G. F. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00003 · Cited by 998
Bone formation by three-dimensional stromal osteoblast culture in biodegradable polymer scaffolds
Ishaug, S. L., Crane, G. M., Miller, M. J., Yasko, A. W., Yaszemski, M. J., & Mikos, A. G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199707)36:1<17::aid-jbm3>3.0.co;2-o · Cited by 833
Three-dimensional culture of rat calvarial osteoblasts in porous biodegradable polymers
Ishaug-Riley, S. L., Crane-Kruger, G. M., Yaszemski, M. J., & Mikos, A. G. (1998) · Biomaterials · doi:10.1016/s0142-9612(98)00021-0 · Cited by 496
Goldstein, A. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00280-5 · Cited by 476
Chondrogenesis in a Cell-Polymer-Bioreactor System
Freed, L. E., Hollander, A. P., Martin, I., Barry, J. R., Langer, R., & Vunjak-Novakovic, G. (1998) · Experimental Cell Research · doi:10.1006/excr.1998.4010 · Cited by 433
Sikavitsas, V. I., Bancroft, G. N., & Mikos, A. G. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10150 · Cited by 388
Iliac crest autogenous bone grafting: donor site complications.
Seiler, J. G., & Johnson, J. (2000) · PubMed · Cited by 275
Tissue engineered microsphere-based matrices for bone repair:
Borden, M., Attawia, M., Khan, Y., & Laurencin, C. T. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00137-5 · Cited by 270
Self-citationPhysical mechanisms of cell damage in microcarrier cell culture bioreactors
Cherry, R. S., & Papoutsakis, E. T. (1988) · Biotechnology and Bioengineering · doi:10.1002/bit.260320808 · Cited by 250
Bone tissue engineering in a rotating bioreactor using a microcarrier matrix system
Botchwey, E. A., Pollack, S. R., Levine, E. M., & Laurencin, C. T. (2001) · Journal of Biomedical Materials Research · doi:10.1002/1097-4636(200105)55:2<242::aid-jbm1011>3.0.co;2-d · Cited by 236
Self-citationReconstruction of bone using calcium phosphate bone cements: A critical review
Schmitz, J. P., Hollinger, J. O., & Milam, S. B. (1999) · Journal of Oral and Maxillofacial Surgery · doi:10.1016/s0278-2391(99)90338-5 · Cited by 217
Tissue engineered bone: Measurement of nutrient transport in three‐dimensional matrices
Botchwey, E. A., Dupree, M. A., Pollack, S. R., Levine, E. M., & Laurencin, C. T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10111 · Cited by 207
Self-citationKomarova, S. V., Ataullakhanov, F. I., & Globus, R. K. (2000) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2000.279.4.c1220 · Cited by 204
Three-dimensional degradable porous polymer-ceramic matrices for use in bone repair
Devin, J. E., Attawia, M. A., & Laurencin, C. T. (1996) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856296x00435 · Cited by 174
Self-citationTissue engineered bone-regeneration using degradable polymers: The formation of mineralized matrices
Laurencin, C. T., Attawia, M. A., Elgendy, H. E., & Herbert, K. M. (1996) · Bone · doi:10.1016/s8756-3282(96)00132-9 · Cited by 168
Self-citationTissue Engineering: Biomedical Applications
Langer, R., Vacanti, J. P., Vacanti, C. A., Atala, A., Freed, L. E., & Vunjak‐Novakovic, G. (1995) · Tissue Engineering · doi:10.1089/ten.1995.1.151 · Cited by 151
Hydrodynamic shear stress and mass transport modulation of endothelial cell metabolism
Nollert, M. U., Diamond, S. L., & McIntire, L. V. (1991) · Biotechnology and Bioengineering · doi:10.1002/bit.260380605 · Cited by 146
Bone formation by osteoblast-like cells in a three-dimensional cell culture
Casser-Bette, M., Murray, A. B., Closs, E. I., Erfle, V., & Schmidt, J. (1990) · Calcified Tissue International · doi:10.1007/bf02555824 · Cited by 124
Development of Technologies Aiding Large-Tissue Engineering
Eiselt, P., Kim, B., Chacko, B., Isenberg, B. C., Peters, M. C., Greene, K. G., Roland, W. D., Loebsack, A. B., Burg, K. J. L., Culberson, C., et al. (1998) · Biotechnology Progress · doi:10.1021/bp970135h · Cited by 112
Granet, C., Laroche, N., Vico, L., Alexandre, C., & Lafage‐Proust, M. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523224 · Cited by 106
Becker, J. L., Prewett, T. L., Spaulding, G. F., & Goodwin, T. J. (1993) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240510307 · Cited by 91
Prewett, T. L., Goodwin, T. J., & Spaulding, G. F. (1993) · Methods in Cell Science · doi:10.1007/bf02387287 · Cited by 74
Skeletal muscle satellite cells cultured in simulated microgravity
Molnar, G., Schroedl, N. A., Gonda, S. R., & Hartzell, C. R. (1997) · In Vitro Cellular & Developmental Biology - Animal · doi:10.1007/s11626-997-0010-9 · Cited by 66
Qiu, Q., Ducheyne, P., Gao, H., & AYYASWAMY, P. S. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.19 · Cited by 65
Numerical Model and Experimental Validation of Microcarrier Motion in a Rotating Bioreactor
Pollack, S. R., Meaney, D. F., Levine, E. M., Litt, M., & Johnston, E. D. (2000) · Tissue Engineering · doi:10.1089/107632700750022161 · Cited by 62
Self-citationUse of microgravity bioreactors for development of an in vitro rat salivary gland cell culture model
Lewis, M. L., Moriarity, D. M., & Campbell, P. S. (1993) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240510305 · Cited by 35
Utilization of microgravity bioreactors for differentiation of mammalian skeletal tissue
Klement, B. J., & Spooner, B. S. (1993) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240510303 · Cited by 33
Cited by
Bone Tissue Engineering: Recent Advances and Challenges
Amini, A. R., Laurencin, C. T., & Nukavarapu, S. P. (2012) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v40.i5.10 · Cited by 2,336
Self-citationLaurencin, C., Khan, Y., & El-Amin, S. F. (2006) · Expert Review of Medical Devices · doi:10.1586/17434440.3.1.49 · Cited by 716
Self-citationEngineered Microenvironments for Controlled Stem Cell Differentiation
Burdick, J. A., & Vunjak-Novakovic, G. (2009) · Tissue Engineering Part A · doi:10.1089/ten.tea.2008.0131 · Cited by 485
Biomaterials for Bone Regenerative Engineering
Yu, X., Tang, X., Gohil, S. V., & Laurencin, C. T. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400760 · Cited by 418
Self-citationDatta, N., P. Pham, Q., Sharma, U., Sikavitsas, V. I., Jansen, J. A., & Mikos, A. G. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0505661103 · Cited by 411
Metadata
- Authors
- Yu, X., Botchwey, E. A., Levine, E. M., Pollack, S. R., & Laurencin, C. T.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-07-26
- Volume
- 101
- Issue
- 31
- Pages
- 11203-11208
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2129086150
- Cited by
- 296
- References
- 32
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.