Shape transitions of fluid vesicles and red blood cells in capillary flows
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
The dynamics of fluid vesicles and red blood cells (RBCs) in cylindrical capillary flow is studied by using a three-dimensional mesoscopic simulation approach. As flow velocity increases, a model RBC is found to transit from a nonaxisymmetric discocyteto an axisymmetric parachute shape (coaxial with the flow axis), while a fluid vesicle is found to transit from a discocyte to a prolate ellipsoid. Both shape transitions reduce the flow resistance. The critical velocities of the shape transitions are linearly dependent on the bending rigidity and on the shear modulus of the membrane. Slipper-like shapes of the RBC model are observed around the transition velocities. Our results are in good agreement with experiments on RBCs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastic Properties of Lipid Bilayers: Theory and Possible Experiments
Helfrich, W. (1973) · Zeitschrift für Naturforschung C · doi:10.1515/znc-1973-11-1209 · Cited by 6,141
Configurations of fluid membranes and vesicles
Seifert, U. (1997) · Advances in Physics · doi:10.1080/00018739700101488 · Cited by 1,650
Mesoscopic model for solvent dynamics
Malevanets, A., & Kapral, R. (1999) · The Journal of Chemical Physics · doi:10.1063/1.478857 · Cited by 1,027
Red Cell Deformability and its Relevance to Blood Flow
Chien, S. (1987) · Annual Review of Physiology · doi:10.1146/annurev.ph.49.030187.001141 · Cited by 570
Mohandas, N., & Evans, E. (1994) · Annual Review of Biophysics and Biomolecular Structure · doi:10.1146/annurev.bb.23.060194.004035 · Cited by 560
Defects in flexible membranes with crystalline order
Seung, H. S., & Nelson, D. R. (1988) · Physical Review A · doi:10.1103/physreva.38.1005 · Cited by 555
Biophysical aspects of blood flow in the microvasculature
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1996) · Cardiovascular Research · doi:10.1016/s0008-6363(96)00065-x · Cited by 553
Lim H. W., G., Wortis, M., & Mukhopadhyay, R. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.202617299 · Cited by 520
Stochastic rotation dynamics: A Galilean-invariant mesoscopic model for fluid flow
Ihle, T., & Kroll, D. M. (2001) · Physical Review E · doi:10.1103/physreve.63.020201 · Cited by 505
Shelby, J. P., White, J., Ganesan, K., Rathod, P. K., & Chiu, D. T. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2433968100 · Cited by 433
Cited by
Computer Simulation of Liquids
Allen, M. P., & Tildesley, D. J. (2017) · doi:10.1093/oso/9780198803195.001.0001 · Cited by 20,945
Physical Principles of Nanoparticle Cellular Endocytosis
Zhang, S., Gao, H., & Bao, G. (2015) · ACS Nano · doi:10.1021/acsnano.5b03184 · Cited by 1,103
Real-time deformability cytometry: on-the-fly cell mechanical phenotyping
Otto, O., Rosendahl, P., Mietke, A., Golfier, S., Herold, C., Klaue, D., Girardo, S., Pagliara, S., Ekpenyong, A., Jacobi, A., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3281 · Cited by 736
Hill, R. A., Tong, L., Yuan, P., Murikinati, S., Gupta, S., & Grutzendler, J. (2015) · Neuron · doi:10.1016/j.neuron.2015.06.001 · Cited by 722
A Multiscale Red Blood Cell Model with Accurate Mechanics, Rheology, and Dynamics
Fedosov, D. A., Caswell, B., & Karniadakis, G. E. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.02.002 · Cited by 618
(2009) · JuSER (Forschungszentrum Jülich) · Cited by 465
Accurate Coarse-Grained Modeling of Red Blood Cells
Pivkin, I. V., & Karniadakis, G. E. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.118105 · Cited by 391
Predicting human blood viscosity in silico
Fedosov, D. A., Pan, W., Caswell, B., Gompper, G., & Karniadakis, G. E. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1101210108 · Cited by 371
Self-citationClogging of microfluidic systems
Dressaire, E., & Sauret, A. (2017) · Soft Matter · doi:10.1039/c6sm01879c · Cited by 370
Schwarz, U. S., & Safran, S. A. (2013) · Reviews of Modern Physics · doi:10.1103/revmodphys.85.1327 · Cited by 361
Multiparticle Collision Dynamics: Simulation of Complex Systems on Mesoscales
Kapral, R. (2008) · Advances in Chemical Physics · doi:10.1002/9780470371572.ch2 · Cited by 333
Fluid lipid membranes: From differential geometry to curvature stresses
Deserno, M. (2015) · Chemistry and Physics of Lipids · doi:10.1016/j.chemphyslip.2014.05.001 · Cited by 328
Numerical Simulation of Flowing Blood Cells
Freund, J. B. (2014) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-010313-141349 · Cited by 323
Biological and synthetic membranes: What can be learned from a coarse-grained description?
MULLER, M., KATSOV, K., & SCHICK, M. (2006) · Physics Reports · doi:10.1016/j.physrep.2006.08.003 · Cited by 320
Adaptive locomotion of artificial microswimmers
Huang, H.-W., Uslu, F. E., Katsamba, P., Lauga, E., Sakar, M. S., & Nelson, B. J. (2019) · Science Advances · doi:10.1126/sciadv.aau1532 · Cited by 304
Flow-induced clustering and alignment of vesicles and red blood cells in microcapillaries
McWhirter, J. L., Noguchi, H., & Gompper, G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0811484106 · Cited by 300
Self-citationTuned, driven, and active soft matter
Menzel, A. M. (2015) · Physics Reports · doi:10.1016/j.physrep.2014.10.001 · Cited by 295
Multiscale modeling of blood flow: from single cells to blood rheology
Fedosov, D. A., Noguchi, H., & Gompper, G. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0497-9 · Cited by 277
Self-citationSemidilute Polymer Solutions at Equilibrium and under Shear Flow
Huang, C.-C., Winkler, R. G., Sutmann, G., & Gompper, G. (2010) · Macromolecules · doi:10.1021/ma101836x · Cited by 182
Self-citationVeerapaneni, S. K., Gueyffier, D., Zorin, D., & Biros, G. (2009) · Journal of Computational Physics · doi:10.1016/j.jcp.2008.11.036 · Cited by 173
“In addition, vesicle mechanics have been used as models for red blood cells [22] [24] and drug-carrying capsules [34].”
MethodThe Fluid Mechanics of Cancer and Its Therapy
Koumoutsakos, P., Pivkin, I., & Milde, F. (2013) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101102 · Cited by 129
“…modeling approaches have been used for them (Boal et al. 1992; Discher et al. 1998; Eggleton & Popel 1998; Fedosov et al. 2010; Freund & Orescanin 2011; Hansen et al. 1997; Li et al. 2005, 2007; Liu & Liu 2006; Noguchi & Gompper 2005; Pozrikidis 2005; Skotheim & Secomb 2007; Wu & Aidun 2010).”
MethodNanocosmetics and Nanomedicines
(2011) · doi:10.1007/978-3-642-19792-5 · Cited by 116
Red blood cell dynamics: from cell deformation to ATP release
Wan, J., Forsyth, A. M., & Stone, H. A. (2011) · Integrative Biology · doi:10.1039/c1ib00044f · Cited by 88
Liu, J., Liu, J., Mu, W., Ma, Q., Zhai, X., Jin, B., Liu, Y., & Zhang, N. (2024) · ACS Nano · doi:10.1021/acsnano.4c02380 · Cited by 74
Metadata
- Authors
- Noguchi, H., & Gompper, G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-09-26
- Volume
- 102
- Issue
- 40
- Pages
- 14159-14164
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2060933310
- Cited by
- 580
- References
- 33
- FWCI
- 11.10
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.