Spatiotemporal dynamics of guanosine 3′,5′-cyclic monophosphate revealed by a genetically encoded, fluorescent indicator
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
To investigate the dynamics of guanosine 3′,5′-cyclic monophosphate (cGMP) in single living cells, we constructed genetically encoded, fluorescent cGMP indicators by bracketing cGMP-dependent protein kinase (cGPK), minus residues 1–77, between cyan and yellow mutants of green fluorescent protein. cGMP decreased fluorescence resonance energy transfer (FRET) and increased the ratio of cyan to yellow emissions by up to 1.5-fold with apparent dissociation constants of ≈2 μM and >100:1 selectivity for cGMP over cAMP. To eliminate constitutive kinase activity, Thr 516 of cGPK was mutated to Ala. Emission ratio imaging of the indicators transfected into rat fetal lung fibroblast (RFL)-6 showed cGMP transients resulting from activation of soluble and particulate guanylyl cyclase, respectively, by nitric oxide (NO) and C-type natriuretic peptide (CNP). Whereas all naive cells tested responded to CNP, only 68% responded to NO. Both sets of signals showed large and variable (0.5–4 min) latencies. The phosphodiesterase (PDE) inhibitor 3-isobutyl-1-methylxanthine (IBMX) did not elevate cGMP on its own but consistently amplified responses to NO or CNP, suggesting that basal activity of guanylate cyclase is very low and emphasizing the importance of PDEs in cGMP recycling. A fraction of RFL cells showed slowly propagating tides of cGMP spreading across the cell in response to delocalized application of NO. Biolistically transfected Purkinje neurons showed cGMP responses to parallel fiber activity and NO donors, confirming that single-cell increases in cGMP occur under conditions appropriate to cause synaptic plasticity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Self-citation(2009) · Mycoses · doi:10.1111/j.1439-0507.1970.tb01233.x · Cited by 1,406
Neurotrophins regulate dendritic growth in developing visual cortex
McAllister, A. K., Lo, D. C., & Katz, L. C. (1995) · Neuron · doi:10.1016/0896-6273(95)90171-x · Cited by 959
Maragos, C. M., Morley, D., Wink, D. A., Dunams, T. M., Saavedra, J. E., Hoffman, A., Bove, A. A., Isaac, L., Hrabie, J. A., & Keefer, L. K. (1991) · Journal of Medicinal Chemistry · doi:10.1021/jm00115a013 · Cited by 722
Fluorescence ratio imaging of cyclic AMP in single cells
Adams, S. R., Harootunian, A. T., Buechler, Y. J., Taylor, S. S., & Tsien, R. Y. (1991) · Nature · doi:10.1038/349694a0 · Cited by 696
Self-citationRegulation of Myosin Phosphatase by a Specific Interaction with cGMP- Dependent Protein Kinase Iα
Surks, H. K., Mochizuki, N., Kasai, Y., Georgescu, S. P., Tang, K. M., Ito, M., Lincoln, T. M., & Mendelsohn, M. E. (1999) · Science · doi:10.1126/science.286.5444.1583 · Cited by 527
A genetically encoded, fluorescent indicator for cyclic AMP in living cells
Zaccolo, M., De Giorgi, F., Cho, C. Y., Feng, L., Knapp, T., Negulescu, P. A., Taylor, S. S., Tsien, R. Y., & Pozzan, T. (2000) · Nature Cell Biology · doi:10.1038/71345 · Cited by 485
Self-citationCyclic AMP Mediates a Presynaptic Form of LTP at Cerebellar Parallel Fiber Synapses
Salin, P. A., Malenka, R. C., & Nicoll, R. A. (1996) · Neuron · doi:10.1016/s0896-6273(00)80099-9 · Cited by 437
Miyawaki, A., & Tsien, R. Y. (2000) · Methods in Enzymology · doi:10.1016/s0076-6879(00)27297-2 · Cited by 409
Self-citationOptical Imaging of Calcium Transients in Neurons and Pharyngeal Muscle of C. elegans
Kerr, R., Lev-Ram, V., Baird, G., Vincent, P., Tsien, R. Y., & Schafer, W. R. (2000) · Neuron · doi:10.1016/s0896-6273(00)81196-4 · Cited by 405
Self-citation
Cited by
Creating new fluorescent probes for cell biology
Zhang, J., Campbell, R. E., Ting, A. Y., & Tsien, R. Y. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm976 · Cited by 1,981
Self-citationFluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Studying protein dynamics in living cells
Lippincott-Schwartz, J., Snapp, E., & Kenworthy, A. (2001) · Nature Reviews Molecular Cell Biology · doi:10.1038/35073068 · Cited by 1,190
Reducing the Environmental Sensitivity of Yellow Fluorescent Protein
Griesbeck, O., Baird, G. S., Campbell, R. E., Zacharias, D. A., & Tsien, R. Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m102815200 · Cited by 1,023
Self-citationCyclic nucleotide research — still expanding after half a century
Beavo, J. A., & Brunton, L. L. (2002) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm911 · Cited by 903
Nitric oxide signalling in plants
Neill, S. J., Desikan, R., & Hancock, J. T. (2003) · New Phytologist · doi:10.1046/j.1469-8137.2003.00804.x · Cited by 874
Emerging issues of connexin channels: biophysics fills the gap
L. Harris, A. (2001) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583501003705 · Cited by 800
Genetically encoded reporters of protein kinase A activity reveal impact of substrate tethering
Zhang, J., Ma, Y., Taylor, S. S., & Tsien, R. Y. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.211566798 · Cited by 597
Self-citationDimerization: An Emerging Concept for G Protein–Coupled Receptor Ontogeny and Function
Angers, S., Salahpour, A., & Bouvier, M. (2002) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev.pharmtox.42.091701.082314 · Cited by 586
Persistent cAMP-Signals Triggered by Internalized G-Protein–Coupled Receptors
Calebiro, D., Nikolaev, V. O., Gagliani, M. C., de Filippis, T., Dees, C., Tacchetti, C., Persani, L., & Lohse, M. J. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000172 · Cited by 574
Fluorescent proteins as a toolkit for in vivo imaging
Chudakov, D. M., Lukyanov, S., & Lukyanov, K. A. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.10.005 · Cited by 498
Greenwald, E. C., Mehta, S., & Zhang, J. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00333 · Cited by 495
Visualization of the Spatial and Temporal Dynamics of Intracellular Signaling
Miyawaki, A. (2003) · Developmental Cell · doi:10.1016/s1534-5807(03)00060-1 · Cited by 455
Ponsioen, B., Zhao, J., Riedl, J., Zwartkruis, F., van der Krogt, G., Zaccolo, M., Moolenaar, W. H., Bos, J. L., & Jalink, K. (2004) · EMBO reports · doi:10.1038/sj.embor.7400290 · Cited by 444
Cyclic GMP signaling in cardiovascular pathophysiology and therapeutics
Tsai, E. J., & Kass, D. A. (2009) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2009.02.009 · Cited by 420
Dynamics of cAMP-Dependent Protein Kinase
Johnson, D. A., Akamine, P., Radzio-Andzelm, E., Madhusudan, & Taylor, S. S. (2001) · Chemical Reviews · doi:10.1021/cr000226k · Cited by 393
Fischmeister, R., Castro, L. R. V., Abi-Gerges, A., Rochais, F., Jurevičius, J., Leroy, J., & Vandecasteele, G. (2006) · Circulation Research · doi:10.1161/01.res.0000246118.98832.04 · Cited by 367
Genetically Encodable Fluorescent Biosensors for Tracking Signaling Dynamics in Living Cells
Newman, R. H., Fosbrink, M. D., & Zhang, J. (2011) · Chemical Reviews · doi:10.1021/cr100002u · Cited by 353
Lohse, M. J., Nuber, S., & Hoffmann, C. (2012) · Pharmacological Reviews · doi:10.1124/pr.110.004309 · Cited by 307
Fluorescent indicators for imaging protein phosphorylation in single living cells
Sato, M., Ozawa, T., Inukai, K., Asano, T., & Umezawa, Y. (2002) · Nature Biotechnology · doi:10.1038/nbt0302-287 · Cited by 280
Mongillo, M., Tocchetti, C. G., Terrin, A., Lissandron, V., Cheung, Y.-F., Dostmann, W. R., Pozzan, T., Kass, D. A., Paolocci, N., Houslay, M. D., et al. (2006) · Circulation Research · doi:10.1161/01.res.0000200178.34179.93 · Cited by 278
Self-citationCyclic Guanosine Monophosphate Compartmentation in Rat Cardiac Myocytes
Castro, L. R. V., Verde, I., Cooper, D. M. F., & Fischmeister, R. (2006) · Circulation · doi:10.1161/circulationaha.105.599241 · Cited by 274
Endocannabinoids Control the Induction of Cerebellar LTD
Safo, P. K., & Regehr, W. G. (2005) · Neuron · doi:10.1016/j.neuron.2005.09.020 · Cited by 263
van Roessel, P., & Brand, A. H. (2002) · Nature Cell Biology · doi:10.1038/ncb0102-e15 · Cited by 233
van Rheenen, J., Langeslag, M., & Jalink, K. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74307-6 · Cited by 225
Measuring protein conformational changes by FRET/LRET
Heyduk, T. (2002) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(02)00332-4 · Cited by 224
Fluorescent biosensors of protein function
VanEngelenburg, S. B., & Palmer, A. E. (2008) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2008.01.020 · Cited by 208
Detection and quantification of nitric oxide–derived oxidants in biological systems
Möller, M. N., Rios, N., Trujillo, M., Radi, R., Denicola, A., & Alvarez, B. (2019) · Journal of Biological Chemistry · doi:10.1074/jbc.rev119.006136 · Cited by 187
Fluorescent sensors for rapid monitoring of intracellular cGMP
Nikolaev, V. O., Gambaryan, S., & Lohse, M. J. (2006) · Nature Methods · doi:10.1038/nmeth816 · Cited by 177
Flavoprotein Autofluorescence Imaging of Neuronal Activation in the Cerebellar Cortex In Vivo
Reinert, K. C., Dunbar, R. L., Gao, W., Chen, G., & Ebner, T. J. (2004) · Journal of Neurophysiology · doi:10.1152/jn.01275.2003 · Cited by 172
Biochemistry of Mobile Zinc and Nitric Oxide Revealed by Fluorescent Sensors
Pluth, M. D., Tomat, E., & Lippard, S. J. (2011) · Annual Review of Biochemistry · doi:10.1146/annurev-biochem-061009-091643 · Cited by 171
“Increases in endogenous NO were observed by the FRET construct cygnet-2 (130).”
Stangherlin, A., Gesellchen, F., Zoccarato, A., Terrin, A., Fields, L. A., Berrera, M., Surdo, N. C., Craig, M. A., Smith, G., Hamilton, G., et al. (2011) · Circulation Research · doi:10.1161/circresaha.110.230698 · Cited by 165
Nausch, L. W. M., Ledoux, J., Bonev, A. D., Nelson, M. T., & Dostmann, W. R. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710387105 · Cited by 164
Self-citationKurokawa, K., Mochizuki, N., Ohba, Y., Mizuno, H., Miyawaki, A., & Matsuda, M. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m104341200 · Cited by 163
Cortese-Krott, M. M., Fernandez, B. O., Santos, J. L. T., Mergia, E., Grman, M., Nagy, P., Kelm, M., Butler, A., & Feelisch, M. (2014) · Redox Biology · doi:10.1016/j.redox.2013.12.031 · Cited by 153
Fluorescent Protein Applications in Microscopy
Straight, A. F. (2007) · Methods in Cell Biology · doi:10.1016/s0091-679x(06)81006-x · Cited by 24
“A number of diVerent biosensors based on this energy transfer system have now been used to detect cyclic-AMP, sugars, protease activity, kinase activity, and more (Fig. 8; Fehr et al., 2005; Honda et al., 2001; Luo et al., 2001; Sato et al., 2000; Zaccolo et al., 2000).”
Background
Metadata
- Authors
- Honda, A., Adams, S. R., Sawyer, C. L., Lev-Ram, V., Tsien, R. Y., & Dostmann, W. R. G.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2001-02-27
- Volume
- 98
- Issue
- 5
- Pages
- 2437-2442
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2156715387
- Cited by
- 266
- References
- 28
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.