The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Cooperative deformation of mineral and collagen in bone at the nanoscale
Open accessAbstract
In biomineralized tissues such as bone, the recurring structural motif at the supramolecular level is an anisotropic stiff inorganic component reinforcing the soft organic matrix. The high toughness and defect tolerance of natural biomineralized composites is believed to arise from these nanometer scale structural motifs. Specifically, load transfer in bone has been proposed to occur by a transfer of tensile strains between the stiff inorganic (mineral apatite) particles via shearing in the intervening soft organic (collagen) layers. This raises the question as to how and to what extent do the mineral particles and fibrils deform concurrently in response to tissue deformation. Here we show that both mineral nanoparticles and the enclosing mineralized fibril deform initially elastically, but to different degrees. Using in situ tensile testing with combined high brilliance synchrotron X-ray diffraction and scattering on the same sample, we show that tissue, fibrils, and mineral particles take up successively lower levels of strain, in a ratio of 12:5:2. The maximum strain seen in mineral nanoparticles (≈0.15–0.20%) can reach up to twice the fracture strain calculated for bulk apatite. The results are consistent with a staggered model of load transfer in bone matrix, exemplifying the hierarchical nature of bone deformation. We believe this process results in a mechanism of fibril–matrix decoupling for protecting the brittle mineral phase in bone, while effectively redistributing the strain energy within the bone tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Composite Materials
Clyne, T. W., & Hull, D. (2019) · Cambridge University Press eBooks · doi:10.1017/9781139050586 · Cited by 3,018
THE MATERIAL BONE: Structure-Mechanical Function Relations
Weiner, S., & Wagner, H. D. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.271 · Cited by 2,724
Materials become insensitive to flaws at nanoscale: Lessons from nature
Gao, H., Ji, B., Jäger, I. L., Arzt, E., & Fratzl, P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0631609100 · Cited by 1,922
Self-citationAn Introduction to Composite Materials
Hull, D., & Clyne, T. W. (1996) · Cambridge University Press eBooks · doi:10.1017/cbo9781139170130 · Cited by 1,450
Structure and mechanical quality of the collagen–mineral nano-composite in bone
Fratzl, P., Gupta, H. S., Paschalis, E. P., & Roschger, P. (2004) · J. Mater. Chem. · doi:10.1039/b402005g · Cited by 1,222
Self-citationBones: Structure and Mechanics
Currey, J. D. (2002) · Cited by 1,125
Bones: Structure and Mechanics
Currey, J. D. (2002) · Princeton University Press eBooks · doi:10.1515/9781400849505 · Cited by 1,000
Fantner, G. E., Hassenkam, T., Kindt, J. H., Weaver, J. C., Birkedal, H., Pechenik, L., Cutroni, J. A., Cidade, G. A. G., Stucky, G. D., Morse, D. E., et al. (2005) · Nature Materials · doi:10.1038/nmat1428 · Cited by 933
Mineralized Collagen Fibrils: A Mechanical Model with a Staggered Arrangement of Mineral Particles
Jäger, I., & Fratzl, P. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76426-5 · Cited by 793
Self-citationMechanistic fracture criteria for the failure of human cortical bone
Nalla, R. K., Kinney, J. H., & Ritchie, R. O. (2003) · Nature Materials · doi:10.1038/nmat832 · Cited by 730
Mechanical Testing of Bone and the Bone-Implant Interface
(1999) · CRC Press eBooks · doi:10.1201/9781420073560 · Cited by 709
Gao, H. (2006) · International Journal of Fracture · doi:10.1007/s10704-006-7156-4 · Cited by 466
Landis, W. J., Hodgens, K. J., Arena, J., Song, M. J., & McEwen, B. F. (1996) · Microscopy Research and Technique · doi:10.1002/(sici)1097-0029(19960201)33:2<192::aid-jemt9>3.0.co;2-v · Cited by 447
Calibration and correction of spatial distortions in 2D detector systems
Hammersley, A. P., Svensson, S. O., & Thompson, A. (1994) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/0168-9002(94)90720-x · Cited by 413
Gao, H. (2007) · Advances in Fracture Research · doi:10.1007/978-1-4020-5423-5_8 · Cited by 354
Nanoscale Deformation Mechanisms in Bone
Gupta, H. S., Wagermaier, W., Zickler, G. A., Raz-Ben Aroush, D., Funari, S. S., Roschger, P., Wagner, H. D., & Fratzl, P. (2005) · Nano Letters · doi:10.1021/nl051584b · Cited by 350
Self-citationSintering effects on the strength of hydroxyapatite
Ruys, A. J., Wei, M., Sorrell, C. C., Dickson, M. R., Brandwood, A., & Milthorpe, B. K. (1995) · Biomaterials · doi:10.1016/0142-9612(95)98859-c · Cited by 319
High-resolution AFM imaging of intact and fractured trabecular bone
Hassenkam, T., Fantner, G. E., Cutroni, J. A., Weaver, J. C., Morse, D. E., & Hansma, P. K. (2004) · Bone · doi:10.1016/j.bone.2004.02.024 · Cited by 270
SAXS and USAXS on the high brilliance beamline at the ESRF
Narayanan, T., Diat, O., & Bösecke, P. (2001) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(01)00553-8 · Cited by 267
Carden, A., Rajachar, R. M., Morris, M. D., & Kohn, D. H. (2003) · Calcified Tissue International · doi:10.1007/s00223-002-1039-0 · Cited by 201
Hierarchies in Biomineral Structures
Currey, J. D. (2005) · Science · doi:10.1126/science.1113954 · Cited by 185
Misof, K., Landis, W. J., Klaushofer, K., & Fratzl, P. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119519 · Cited by 171
Self-citationInternal strains and stresses measured in cortical bone via high-energy X-ray diffraction
Almer, J., & Stock, S. R. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.08.003 · Cited by 168
Mechanisms governing the inelastic deformation of cortical bone and application to trabecular bone
Mercer, C., He, M. Y., Wang, R., & Evans, A. G. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.08.004 · Cited by 165
Fibrillar level fracture in bone beyond the yield point
Gupta, H. S., Wagermaier, W., Zickler, G. A., Hartmann, J., Funari, S. S., Roschger, P., Wagner, H. D., & Fratzl, P. (2006) · International Journal of Fracture · doi:10.1007/s10704-006-6635-y · Cited by 101
Self-citationSynchrotron Diffraction Study of Deformation Mechanisms in Mineralized Tendon
Gupta, H. S., Messmer, P., Roschger, P., Bernstorff, S., Klaushofer, K., & Fratzl, P. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.158101 · Cited by 92
Self-citation
Cited by
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
Self-citationBone grafts and biomaterials substitutes for bone defect repair: A review
Wang, W., & Yeung, K. W. K. (2017) · Bioactive Materials · doi:10.1016/j.bioactmat.2017.05.007 · Cited by 1,938
Eliaz, N., & Metoki, N. (2017) · Materials · doi:10.3390/ma10040334 · Cited by 1,088
Biological materials: Functional adaptations and bioinspired designs
Chen, P.-Y., McKittrick, J., & Meyers, M. A. (2012) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.03.001 · Cited by 766
On the Mechanistic Origins of Toughness in Bone
Launey, M. E., Buehler, M. J., & Ritchie, R. O. (2010) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-070909-104427 · Cited by 741
Metadata
- Authors
- Gupta, H. S., Seto, J., Wagermaier, W., Zaslansky, P., Boesecke, P., & Fratzl, P.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-11-21
- Volume
- 103
- Issue
- 47
- Pages
- 17741-17746
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2150238384
- Cited by
- 644
- References
- 27
- FWCI
- 12.74
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.