CoChat

Materials become insensitive to flaws at nanoscale: Lessons from nature

Open access
Gao, Huajian, Ji, Baohua, Jäger, Ingomar L., Arzt, Eduard, Fratzl, Peter · 2003 · Proceedings of the National Academy of Sciences

The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.

Abstract

Natural materials such as bone, tooth, and nacre are nanocomposites of proteins and minerals with superior strength. Why is the nanometer scale so important to such materials? Can we learn from this to produce superior nanomaterials in the laboratory? These questions motivate the present study where we show that the nanocomposites in nature exhibit a generic mechanical structure in which the nanometer size of mineral particles is selected to ensure optimum strength and maximum tolerance of flaws (robustness). We further show that the widely used engineering concept of stress concentration at flaws is no longer valid for nanomaterial design.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0631609100

Cites

24 of 24 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

2 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 24 references

Research works printed but not linked: 2

  1. Taylor J D. Palaeontology. 1973;16:519–534. [Google Scholar]
  2. Kessler H, Ballarini R, Mullen R L, Kuhn L T, Heuer A H. Comput Mater Sci. 1996;5:157–166. [Google Scholar]

Cited by

Items 401–500 of 1,000

Metadata

Authors
Gao, H., Ji, B., Jäger, I. L., Arzt, E., & Fratzl, P.
Affiliations
Austrian Academy of Sciences (AT)
Venue
Proceedings of the National Academy of Sciences
Published
2003-05-05
Volume
100
Issue
10
Pages
5597-5600
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W2040957028
Cited by
1,922
References
24
Citations by year
2026: 74 · 2025: 91 · 2024: 74 · 2023: 89 · 2022: 95 · 2021: 109 · 2020: 129 · 2019: 103 · 2018: 93 · 2017: 93 · 2016: 105 · 2015: 112 · 2014: 81 · 2013: 87 · 2012: 101
FWCI
24.62
Type
journal article
Language
en
Open access
Locations
  • Proceedings of the National Academy of Sciences (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
  • Max Planck Institute for Plasma Physics (submittedVersion)
  • Max Planck Digital Library (submittedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion)
Funders
  • National Natural Science Foundation of China
  • Tsinghua University
  • Max-Planck-Gesellschaft
  • Changjiang Scholar Program of Chinese Ministry of Education
Topics
  • Physical Sciences › Materials Science › Biomaterials › Calcium Carbonate Crystallization and Inhibition
  • Physical Sciences › Materials Science › Metals and Alloys › Microstructure and mechanical properties
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
Keywords
nanocomposites, fracture toughness, flaw tolerance, stress concentration, bone, teeth, nacre, biomimetic materials, mechanical strength, nanomaterial design
MeSH terms
Animals, Bone and Bones, Minerals, Miniaturization, Ostreidae, Sensitivity and Specificity, Stress, Mechanical, Tooth, Vertebrates

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.