Continuous inertial focusing, ordering, and separation of particles in microchannels
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Under laminar flow conditions, when no external forces are applied, particles are generally thought to follow fluid streamlines. Contrary to this perspective, we observe that flowing particles migrate across streamlines in a continuous, predictable, and accurate manner in microchannels experiencing laminar flows. The migration is attributed to lift forces on particles that are observed when inertial aspects of the flow become significant. We identified symmetric and asymmetric channel geometries that provide additional inertial forces that bias particular equilibrium positions to create continuous streams of ordered particles precisely positioned in three spatial dimensions. We were able to order particles laterally, within the transverse plane of the channel, with >80-nm accuracy, and longitudinally, in regular chains along the direction of flow. A fourth dimension of rotational alignment was observed for discoidal red blood cells. Unexpectedly, ordering appears to be independent of particle buoyant direction, suggesting only minor centrifugal contributions. Theoretical analysis indicates the physical principles are operational over a range of channel and particle length scales. The ability to differentially order particles of different sizes, continuously, at high rates, and without external forces in microchannels is expected to have a broad range of applications in continuous bioparticle separation, high-throughput cytometry, and large-scale filtration systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous Particle Separation Through Deterministic Lateral Displacement
Huang, L. R., Cox, E. C., Austin, R. H., & Sturm, J. C. (2004) · Science · doi:10.1126/science.1094567 · Cited by 1,634
Berger, S. A., Talbot, L., & Yao, L. S. (1983) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.15.010183.002333 · Cited by 1,363
Microfluidic sorting in an optical lattice
MacDonald, M. P., Spalding, G. C., & Dholakia, K. (2003) · Nature · doi:10.1038/nature02144 · Cited by 1,246
Radial Particle Displacements in Poiseuille Flow of Suspensions
SEGRÉ, G., & SILBERBERG, A. (1961) · Nature · doi:10.1038/189209a0 · Cited by 1,206
Field-Flow Fractionation: Analysis of Macromolecular, Colloidal, and Particulate Materials
Giddings, J. C. (1993) · Science · doi:10.1126/science.8502990 · Cited by 1,141
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Self-citationDeterministic hydrodynamics: Taking blood apart
Davis, J. A., Inglis, D. W., Morton, K. J., Lawrence, D. A., Huang, L. R., Chou, S. Y., Sturm, J. C., & Austin, R. H. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0605967103 · Cited by 622
Particle Motions in a Viscous Fluid
Leal, L. G. (1980) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.12.010180.002251 · Cited by 520
Marker-specific sorting of rare cells using dielectrophoresis
Hu, X., Bessette, P. H., Qian, J., Meinhart, C. D., Daugherty, P. S., & Soh, H. T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507719102 · Cited by 428
Continuous microfluidic immunomagnetic cell separation
Inglis, D. W., Riehn, R., Austin, R. H., & Sturm, J. C. (2004) · Applied Physics Letters · doi:10.1063/1.1823015 · Cited by 353
Sudarsan, A. P., & Ugaz, V. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0507976103 · Cited by 324
Gravity-Driven Microfluidic Particle Sorting Device with Hydrodynamic Separation Amplification
Huh, D., Bahng, J. H., Ling, Y., Wei, H.-H., Kripfgans, O. D., Fowlkes, J. B., Grotberg, J. B., & Takayama, S. (2007) · Analytical Chemistry · doi:10.1021/ac061542n · Cited by 315
Wall-induced forces on a rigid sphere at finite Reynolds number
ZENG, L., BALACHANDAR, S., & FISCHER, P. (2005) · Journal of Fluid Mechanics · doi:10.1017/s0022112005004738 · Cited by 275
Geometrical focusing of cells in a microfluidic device: An approach to separate blood plasma
Faivre, M., Abkarian, M., Bickraj, K., & Stone, H. A. (2006) · Biorheology: The Official Journal of the International Society of Biorheology · doi:10.1177/0006355x2006043002001 · Cited by 196
Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array
Choi, S., & Park, J.-K. (2005) · Lab on a Chip · doi:10.1039/b505088j · Cited by 186
A three-dimensional dielectrophoretic particle focusing channel for microcytometry applications
Yu, C., Vykoukal, J., Vykoukal, D. M., Schwartz, J. A., Shi, L., & Gascoyne, P. R. C. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844839 · Cited by 158
Cited by
Di Carlo, D. (2009) · Lab on a Chip · doi:10.1039/b912547g · Cited by 1,627
Self-citationSingle-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Ozkumur, E., Shah, A. M., Ciciliano, J. C., Emmink, B. L., Miyamoto, D. T., Brachtel, E., Yu, M., Chen, P.-I., Morgan, B., Trautwein, J., et al. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005616 · Cited by 1,086
Self-citationWyatt Shields IV, C., Reyes, C. D., & López, G. P. (2015) · Lab on a Chip · doi:10.1039/c4lc01246a · Cited by 1,036
Fundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017
Metadata
- Authors
- Di Carlo, D., Irimia, D., Tompkins, R. G., & Toner, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-11-27
- Volume
- 104
- Issue
- 48
- Pages
- 18892-18897
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2006197460
- Cited by
- 1,708
- References
- 16
- FWCI
- 24.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.