The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
A genetically encoded fluorescent sensor of ERK activity
Open accessAbstract
The activity of the ERK has complex spatial and temporal dynamics that are important for the specificity of downstream effects. However, current biochemical techniques do not allow for the measurement of ERK signaling with fine spatiotemporal resolution. We developed a genetically encoded, FRET-based sensor of ERK activity (the extracellular signal-regulated kinase activity reporter, EKAR), optimized for signal-to-noise ratio and fluorescence lifetime imaging. EKAR selectively and reversibly reported ERK activation in HEK293 cells after epidermal growth factor stimulation. EKAR signals were correlated with ERK phosphorylation, required ERK activity, and did not report the activities of JNK or p38. EKAR reported ERK activation in the dendrites and nucleus of hippocampal pyramidal neurons in brain slices after theta-burst stimuli or trains of back-propagating action potentials. EKAR therefore permits the measurement of spatiotemporal ERK signaling dynamics in living cells, including in neuronal compartments in intact tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sun, H., Charles, C. H., Lau, L. F., & Tonks, N. K. (1993) · Cell · doi:10.1016/0092-8674(93)90383-2 · Cited by 1,156
Locally dynamic synaptic learning rules in pyramidal neuron dendrites
Harvey, C. D., & Svoboda, K. (2007) · Nature · doi:10.1038/nature06416 · Cited by 625
Self-citationJacobs, D., Glossip, D., Xing, H., Muslin, A. J., & Kornfeld, K. (1999) · Genes & Development · doi:10.1101/gad.13.2.163 · Cited by 439
Lu, P.-J., Zhou, X. Z., Liou, Y.-C., Noel, J. P., & Lu, K. P. (2002) · Journal of Biological Chemistry · doi:10.1074/jbc.c100228200 · Cited by 244
Cited by
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Improving FRET dynamic range with bright green and red fluorescent proteins
Lam, A. J., St-Pierre, F., Gong, Y., Marshall, J. D., Cranfill, P. J., Baird, M. A., McKeown, M. R., Wiedenmann, J., Davidson, M. W., Schnitzer, M. J., et al. (2012) · Nature Methods · doi:10.1038/nmeth.2171 · Cited by 732
Hirata, E., Girotti, M. R., Viros, A., Hooper, S., Spencer-Dene, B., Matsuda, M., Larkin, J., Marais, R., & Sahai, E. (2015) · Cancer Cell · doi:10.1016/j.ccell.2015.03.008 · Cited by 593
Development of an optimized backbone of FRET biosensors for kinases and GTPases
Komatsu, N., Aoki, K., Yamada, M., Yukinaga, H., Fujita, Y., Kamioka, Y., & Matsuda, M. (2011) · Molecular Biology of the Cell · doi:10.1091/mbc.e11-01-0072 · Cited by 577
Imaging Intracellular pH in Live Cells with a Genetically Encoded Red Fluorescent Protein Sensor
Tantama, M., Hung, Y. P., & Yellen, G. (2011) · Journal of the American Chemical Society · doi:10.1021/ja202902d · Cited by 408
Metadata
- Authors
- Harvey, C. D., Ehrhardt, A. G., Cellurale, C., Zhong, H., Yasuda, R., Davis, R. J., & Svoboda, K.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-12-09
- Volume
- 105
- Issue
- 49
- Pages
- 19264-19269
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2040172334
- Cited by
- 345
- References
- 4
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A genetically encoded fluorescent sensor of ERK activity. https://app.cochat.ai/papers/10.1073/pnas.0804598105
- The paper
- Harvey, C. D., Ehrhardt, A. G., Cellurale, C., Zhong, H., Yasuda, R., Davis, R. J., & Svoboda, K. (2008). A genetically encoded fluorescent sensor of ERK activity. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0804598105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.