The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
A sensitive, versatile microfluidic assay for bacterial chemotaxis
Open accessAbstract
We have developed a microfluidic assay for bacterial chemotaxis in which a gradient of chemoeffectors is established inside a microchannel via diffusion between parallel streams of liquid in laminar flow. The random motility and chemotactic responses to l -aspartate, l -serine, l -leucine, and Ni 2+ of WT and chemotactic-mutant strains of Escherichia coli were measured. Migration of the cells was quantified by counting the cells accumulating in each of 22 outlet ports. The sensitivity of the assay is attested to by the significant response of WT cells to 3.2 nM l -aspartate, a concentration three orders of magnitude lower than the detection limit in the standard capillary assay. The response to repellents was as robust and easily recorded as the attractant response. A surprising discovery was that l -leucine is sensed by Tar as an attractant at low concentrations and by Tsr as a repellent at higher concentrations. This assay offers superior performance and convenience relative to the existing assays to measure bacterial tactic responses, and it is flexible enough to be used in a wide range of different applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Crank, J. (1956) · CERN Document Server (European Organization for Nuclear Research) · Cited by 18,978
Park, G. S. (1975) · Polymer · doi:10.1016/0032-3861(75)90130-5 · Cited by 14,967
Escherichia coli and Salmonella :cellular and molecular biology
Neidhardt, F. C. (1996) · ASM Press eBooks · Cited by 8,197
Guzman, L. M., Belin, D., Carson, M. J., & Beckwith, J. (1995) · Journal of Bacteriology · doi:10.1128/jb.177.14.4121-4130.1995 · Cited by 4,935
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Berg, H. C. (2025) · Princeton University Press eBooks · doi:10.1515/9780691279886 · Cited by 2,367
Chemotaxis in Escherichia coli analysed by Three-dimensional Tracking
BERG, H. C., & BROWN, D. A. (1972) · Nature · doi:10.1038/239500a0 · Cited by 2,231
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Adler, J. (1976) · Surface Membrane Receptors · doi:10.1007/978-1-4684-2772-1_29 · Cited by 1,275
The Gradient-Sensing Mechanism in Bacterial Chemotaxis
Macnab, R. M., & Koshland, D. E. (1972) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.69.9.2509 · Cited by 917
Li Jeon, N., Baskaran, H., Dertinger, S. K. W., Whitesides, G. M., Van De Water, L., & Toner, M. (2002) · Nature Biotechnology · doi:10.1038/nbt712 · Cited by 917
ADLER, J. (1973) · Journal of General Microbiology · doi:10.1099/00221287-74-1-77 · Cited by 794
Flagellar rotation and the mechanism of bacterial motility
SILVERMAN, M., & SIMON, M. (1974) · Nature · doi:10.1038/249073a0 · Cited by 723
Adler, J. (1969) · Science · doi:10.1126/science.166.3913.1588 · Cited by 667
Non-genetic individuality: chance in the single cell
Spudich, J. L., & Koshland, D. E. (1976) · Nature · doi:10.1038/262467a0 · Cited by 534
Microfluidic Diffusion-Based Separation and Detection
Weigl, B. H., & Yager, P. (1999) · Science · doi:10.1126/science.283.5400.346 · Cited by 502
Gradients of substrate-bound laminin orient axonal specification of neurons
Dertinger, S. K. W., Jiang, X., Li, Z., Murthy, V. N., & Whitesides, G. M. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.192457199 · Cited by 446
Isolation and behavior of Escherichia coli deletion mutants lacking chemotaxis functions
Parkinson, J. S., & Houts, S. E. (1982) · Journal of Bacteriology · doi:10.1128/jb.151.1.106-113.1982 · Cited by 415
Berg, H. C., & Turner, L. (1990) · Biophysical Journal · doi:10.1016/s0006-3495(90)82436-x · Cited by 356
Mesibov, R., Ordal, G. W., & Adler, J. (1973) · The Journal of General Physiology · doi:10.1085/jgp.62.2.203 · Cited by 283
Design and Characterization of Immobilized Enzymes in Microfluidic Systems
Mao, H., Yang, T., & Cremer, P. S. (2002) · Analytical Chemistry · doi:10.1021/ac010822u · Cited by 235
Self-citationFord, R. M., Phillips, B. R., Quinn, J. A., & Lauffenburger, D. A. (1991) · Biotechnology and Bioengineering · doi:10.1002/bit.260370707 · Cited by 108
A NarX–Tar chimera mediates repellent chemotaxis to nitrate and nitrite
Ward, S. M., Delgado, A., Gunsalus, R. P., & Manson, M. D. (2002) · Molecular Microbiology · doi:10.1046/j.1365-2958.2002.02902.x · Cited by 66
Self-citationWay, S. M. V., Hosking, E. R., Braun, T. F., & Manson, M. D. (2000) · Journal of Molecular Biology · doi:10.1006/jmbi.2000.3548 · Cited by 53
Self-citation
Cited by
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Critical review on biofilm methods
Azeredo, J., Azevedo, N. F., Briandet, R., Cerca, N., Coenye, T., Costa, A. R., Desvaux, M., Di Bonaventura, G., Hébraud, M., Jaglic, Z., et al. (2017) · Critical Reviews in Microbiology · doi:10.1080/1040841x.2016.1208146 · Cited by 1,045
Controlled microfluidic interfaces
Atencia, J., & Beebe, D. J. (2005) · Nature · doi:10.1038/nature04163 · Cited by 1,006
Microfabrication meets microbiology
Weibel, D. B., DiLuzio, W. R., & Whitesides, G. M. (2007) · Nature Reviews Microbiology · doi:10.1038/nrmicro1616 · Cited by 788
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Metadata
- Authors
- Mao, H., Cremer, P. S., & Manson, M. D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2003-04-18
- Volume
- 100
- Issue
- 9
- Pages
- 5449-5454
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2115377824
- Cited by
- 332
- References
- 24
- FWCI
- 6.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.