The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring
Open accessAbstract
Fluorescent microbeads hold great promise for in vivo continuous glucose monitoring with wireless transdermal transmission and long-lasting activity. The full potential of fluorescent microbeads has yet to be realized due to insufficient intensity for transdermal transmission and material toxicity. This paper illustrates the highly-sensitive, biostable, long-lasting, and injectable fluorescent microbeads for in vivo continuous glucose monitoring. We synthesized a fluorescent monomer composed of glucose-recognition sites, a fluorogenic site, spacers, and polymerization sites. The spacers are designed to be long and hydrophilic for increasing opportunities to bind glucose molecules; consequently, the fluorescent monomers enable high-intensive responsiveness to glucose. We then fabricated injectable-sized fluorescent polyacrylamide hydrogel beads with high uniformity and high throughput. We found that our fluorescent beads provide sufficient intensity to transdermally monitor glucose concentrations in vivo. The fluorescence intensity successfully traced the blood glucose concentration fluctuation, indicating our method has potential uses in highly-sensitive and minimally invasive continuous blood glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemistry and molecular cell biology of diabetic complications
Brownlee, M. (2001) · Nature · doi:10.1038/414813a · Cited by 9,107
Global and societal implications of the diabetes epidemic
Zimmet, P., Alberti, K. G. M. M., & Shaw, J. (2001) · Nature · doi:10.1038/414782a · Cited by 5,883
Functional and Molecular Defects of Pancreatic Islets in Human Type 2 Diabetes
Del Guerra, S., Lupi, R., Marselli, L., Masini, M., Bugliani, M., Sbrana, S., Torri, S., Pollera, M., Boggi, U., Mosca, F., et al. (2005) · Diabetes · doi:10.2337/diabetes.54.3.727 · Cited by 466 · cited 1×
“D is a global pandemic affecting over 200 million people (1, 2).”
BackgroundEnzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Cited by
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Döring, A., Birnbaum, W., & Kuckling, D. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60031a · Cited by 391
Glucose Sensing in Supramolecular Chemistry
Sun, X., & James, T. D. (2015) · Chemical Reviews · doi:10.1021/cr500562m · Cited by 386
Metadata
- Authors
- Shibata, H., Heo, Y. J., Okitsu, T., Matsunaga, Y., Kawanishi, T., & Takeuchi, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-10-04
- Volume
- 107
- Issue
- 42
- Pages
- 17894-17898
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2027544789
- Cited by
- 287
- References
- 4
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring. https://app.cochat.ai/papers/10.1073/pnas.1006911107
- The paper
- Shibata, H., Heo, Y. J., Okitsu, T., Matsunaga, Y., Kawanishi, T., & Takeuchi, S. (2010). Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1006911107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.