Activatable aptamer probe for contrast-enhanced in vivo cancer imaging based on cell membrane protein-triggered conformation alteration
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Aptamers have emerged as promising molecular probes for in vivo cancer imaging, but the reported “always-on” aptamer probes remain problematic because of high background and limited contrast. To address this problem, we designed an activatable aptamer probe (AAP) targeting membrane proteins of living cancer cells and achieved contrast-enhanced cancer visualization inside mice. The AAP displayed a quenched fluorescence in its free state and underwent a conformational alteration upon binding to target cancer cells with an activated fluorescence. As proof of concept, in vitro analysis and in vivo imaging of CCRF-CEM cancer cells were performed by using the specific aptamer, sgc8, as a demonstration. It was confirmed that the AAP could be specifically activated by target cancer cells with a dramatic fluorescence enhancement and exhibit improved sensitivity for CCRF-CEM cell analysis with the cell number of 118 detected in 200 μl binding buffer. In vivo studies demonstrated that activated fluorescence signals were obviously achieved in the CCRF-CEM tumor sites in mice. Compared to always-on aptamer probes, the AAP could substantially minimize the background signal originating from nontarget tissues, thus resulting in significantly enhanced image contrast and shortened diagnosis time to 15 min. Furthermore, because of the specific affinity of sgc8 to target cancer cells, the AAP also showed desirable specificity in differentiating CCRF-CEM tumors from Ramos tumors and nontumor areas. The design concept can be widely adapted to other cancer cell-specific aptamer probes for in vivo molecular imaging of cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tuerk, C., & Gold, L. (1990) · Science · doi:10.1126/science.2200121 · Cited by 10,405
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Aptamers evolved from live cells as effective molecular probes for cancer study
Shangguan, D., Li, Y., Tang, Z., Cao, Z. C., Chen, H. W., Mallikaratchy, P., Sefah, K., Yang, C. J., & Tan, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602615103 · Cited by 1,516
Self-citationTumor imaging by means of proteolytic activation of cell-penetrating peptides
Jiang, T., Olson, E. S., Nguyen, Q. T., Roy, M., Jennings, P. A., & Tsien, R. Y. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408191101 · Cited by 822
Selective molecular imaging of viable cancer cells with pH-activatable fluorescence probes
Urano, Y., Asanuma, D., Hama, Y., Koyama, Y., Barrett, T., Kamiya, M., Nagano, T., Watanabe, T., Hasegawa, A., Choyke, P. L., et al. (2009) · Nature Medicine · doi:10.1038/nm.1854 · Cited by 801
Aptamers Generated from Cell-SELEX for Molecular Medicine: A Chemical Biology Approach
Fang, X., & Tan, W. (2010) · Accounts of Chemical Research · doi:10.1021/ar900101s · Cited by 747
Self-citationMolecular Engineering of DNA: Molecular Beacons
Wang, K., Tang, Z., Yang, C. J., Kim, Y., Fang, X., Li, W., Wu, Y., Medley, C. D., Cao, Z., Li, J., et al. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200800370 · Cited by 644
Self-citationOlson, E. S., Jiang, T., Aguilera, T. A., Nguyen, Q. T., Ellies, L. G., Scadeng, M., & Tsien, R. Y. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910283107 · Cited by 567
Daniels, D. A., Chen, H., Hicke, B. J., Swiderek, K. M., & Gold, L. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2136683100 · Cited by 567
Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
Becker, A., Hessenius, C., Licha, K., Ebert, B., Sukowski, U., Semmler, W., Wiedenmann, B., & Grötzinger, C. (2001) · Nature Biotechnology · doi:10.1038/86707 · Cited by 518
Blum, G., von Degenfeld, G., Merchant, M. J., Blau, H. M., & Bogyo, M. (2007) · Nature Chemical Biology · doi:10.1038/nchembio.2007.26 · Cited by 467
Cell-Specific Aptamer Probes for Membrane Protein Elucidation in Cancer Cells
Shangguan, D., Cao, Z., Meng, L., Mallikaratchy, P., Sefah, K., Wang, H., Li, Y., & Tan, W. (2008) · Journal of Proteome Research · doi:10.1021/pr700894d · Cited by 465
Self-citationTumor targeting by an aptamer.
Hicke, B. J., Stephens, A. W., Gould, T. A., Chang, Y.-F., Lynott, C. K., Heil, J., Borkowski, S., Hilger, C. S., Cook, G., Warren, S., et al. (2006) · PubMed · Cited by 384
Aptamer-Conjugated Nanoparticles for the Collection and Detection of Multiple Cancer Cells
Smith, J. E., Medley, C. D., Tang, Z., Shangguan, D., Lofton, C., & Tan, W. (2007) · Analytical Chemistry · doi:10.1021/ac062151b · Cited by 343
Self-citationDNA aptamer–micelle as an efficient detection/delivery vehicle toward cancer cells
Wu, Y., Sefah, K., Liu, H., Wang, R., & Tan, W. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0909611107 · Cited by 330
Self-citationWang, A. Z., Bagalkot, V., Vasilliou, C. C., Gu, F., Alexis, F., Zhang, L., Shaikh, M., Yuet, K., Cima, M. J., Langer, R., et al. (2008) · ChemMedChem · doi:10.1002/cmdc.200800091 · Cited by 312
Hwang, D. W., Ko, H. Y., Lee, J. H., Kang, H., Ryu, S. H., Song, I. C., Lee, D. S., & Kim, S. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069880 · Cited by 293
Application of locked nucleic acids to improve aptamer in vivo stability and targeting function
Schmidt, K. S. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh862 · Cited by 287
In vivo imaging of oligonucleotides with positron emission tomography
Tavitian, B., Terrazzino, S., Kühnast, B., Marzabal, S., Stettler, O., Dollé, F., Deverre, J.-R., Jobert, A., Hinnen, F., Bendriem, B., et al. (1998) · Nature Medicine · doi:10.1038/nm0498-467 · Cited by 200
Ogawa, M., Kosaka, N., Choyke, P. L., & Kobayashi, H. (2009) · ACS Chemical Biology · doi:10.1021/cb900089j · Cited by 187
Optical imaging for cervical cancer detection: solutions for a continuing global problem
Thekkek, N., & Richards-Kortum, R. (2008) · Nature Reviews Cancer · doi:10.1038/nrc2462 · Cited by 176
Ogawa, M., Kosaka, N., Longmire, M. R., Urano, Y., Choyke, P. L., & Kobayashi, H. (2009) · Molecular Pharmaceutics · doi:10.1021/mp800115t · Cited by 113
In vivo Fluorescence Imaging of Tumors using Molecular Aptamers Generated by Cell‐SELEX
Shi, H., Tang, Z., Kim, Y., et al. (2010) · Chemistry - An Asian Journal · doi:10.1002/asia.201000242 · Cited by 107
Self-citationHama, Y., Urano, Y., Koyama, Y., Choyke, P. L., & Kobayashi, H. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-3794 · Cited by 61
Cited by
Cancer biomarker detection: recent achievements and challenges
Wu, L., & Qu, X. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00370e · Cited by 1,214
Current approaches in SELEX: An update to aptamer selection technology
Darmostuk, M., Rimpelova, S., Gbelcova, H., & Ruml, T. (2015) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.02.008 · Cited by 702
Aptamers from Cell-Based Selection for Bioanalytical Applications
Tan, W., Donovan, M. J., & Jiang, J. (2013) · Chemical Reviews · doi:10.1021/cr300468w · Cited by 649
Self-citationAptamer-integrated DNA nanostructures for biosensing, bioimaging and cancer therapy
Meng, H.-M., Liu, H., Kuai, H., Peng, R., Mo, L., & Zhang, X.-B. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00645g · Cited by 608
Aptamer-based targeted therapy
Zhu, G., & Chen, X. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.08.005 · Cited by 522
“Bymodifying aptamers with fluorescent dyes, radioisotopes, or magnetic nanomaterial reporters, aptamers have been explored for molecular imaging by optical bioimaging [94,95], positron emission tomography (PET) or singlephoton emission computed tomography (SPECT) [33,93,96–98], as well as MRI [99,100].”
Metadata
- Authors
- Shi, H., He, X., Wang, K., Wu, X., Ye, X., Guo, Q., Tan, W., Qing, Z., Yang, X., & Zhou, B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-02-22
- Volume
- 108
- Issue
- 10
- Pages
- 3900-3905
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2135883962
- Cited by
- 301
- References
- 26
- FWCI
- 9.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.