Shear stress regulates the endothelial Kir2.1 ion channel
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Endothelial cells (ECs) line the mammalian vascular system and respond to the hemodynamic stimulus of fluid shear stress, the frictional force produced by blood flow. When ECs are exposed to shear stress, one of the fastest responses is an increase of K + conductance, which suggests that ion channels are involved in the early shear stress response. Here we show that an applied shear stress induces a K + ion current in cells expressing the endothelial Kir2.1 channel. This ion current shares the properties of the shear-induced current found in ECs. In addition, the shear current induction can be specifically prevented by tyrosine kinase inhibition. Our findings identify the Kir2.1 channel as an early component of the endothelial shear response mechanism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Cited by
Mechanotransduction in vascular physiology and atherogenesis
Hahn, C., & Schwartz, M. A. (2009) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm2596 · Cited by 1,211
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Effects of shear stress on endothelial cells: go with the flow
Chistiakov, D. A., Orekhov, A. N., & Bobryshev, Y. V. (2017) · Acta Physiologica · doi:10.1111/apha.12725 · Cited by 431
Wojciak-Stothard, B., & Ridley, A. J. (2003) · The Journal of Cell Biology · doi:10.1083/jcb.200210135 · Cited by 344
Potassium Channels in the Peripheral Microcirculation
JACKSON, W. F. (2005) · Microcirculation · doi:10.1080/10739680590896072 · Cited by 338
Vascular and renal function in experimental thyroid disorders
Vargas, F., Moreno, J. M., Rodríguez-Gómez, I., Wangensteen, R., Osuna, A., Álvarez-Guerra, M., & García-Estañ, J. (2006) · European Journal of Endocrinology · doi:10.1530/eje.1.02093 · Cited by 285
Davis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Functional TRPM7 channels accumulate at the plasma membrane in response to fluid flow
Oancea, E., Wolfe, J. T., & Clapham, D. E. (2006) · Circulation Research · doi:10.1161/01.res.0000200179.29375.cc · Cited by 249
Chatterjee, S. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00524 · Cited by 196
Mechanosensing and Mechanoregulation of Endothelial Cell Functions
Fang, Y., Wu, D., & Birukov, K. G. (2019) · Comprehensive Physiology · doi:10.1002/cphy.c180020 · Cited by 180
Integrins as Unique Receptors for Vascular Control
Martinez-Lemus, L. A., Wu, X., Wilson, E., Hill, M. A., Davis, G. E., Davis, M. J., & Meininger, G. A. (2003) · Journal of Vascular Research · doi:10.1159/000071886 · Cited by 175
“This response occurs within seconds, and results in endothelial cell hyperpolarization, which would increase the driving force for Ca 2p and potentially increase production of Ca 2p -dependent autacoids. A recent study has shown that the ion channel involved in this response is K ir 2.1 [”
BackgroundInfluentialQi, Y.-X., Jiang, J., Jiang, X.-H., Wang, X.-D., Ji, S.-Y., Han, Y., Long, D.-K., Shen, B.-R., Yan, Z.-Q., Chien, S., et al. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1019219108 · Cited by 169
“There are many kinds of mechanosensors in ECs, including transmembrane proteins such as integrins (4, 5), ion channels (4, 6), junctional proteins (7, 8), growth factor receptors (7), andGprotein-coupled receptors (9), as well asmembrane lipids (10) and glycocalyx (10, 11).”
BackgroundEndothelial Mechanosignaling: Does One Sensor Fit All?
Givens, C., & Tzima, E. (2016) · Antioxidants & Redox Signaling · doi:10.1089/ars.2015.6493 · Cited by 165
“1 K channel has been shown to be mechanosensitive, and when expressed in Xenopus laevis oocytes, the oocytes become sensitive to shear (69).”
BackgroundEffects of shear stress on endothelial cells: Possible relevance for ultrasound applications
VanBavel, E. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.017 · Cited by 161
Epithelial Na+ Channels Are Activated by Laminar Shear Stress
Carattino, M. D., Sheng, S., & Kleyman, T. R. (2004) · Journal of Biological Chemistry · doi:10.1074/jbc.m311783200 · Cited by 159
Metadata
- Authors
- Hoger, J. H., Ilyin, V. I., Forsyth, S., & Hoger, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-05-21
- Volume
- 99
- Issue
- 11
- Pages
- 7780-7785
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2150038687
- Cited by
- 153
- References
- 1
- FWCI
- 2.81
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.